The DOI matches its Crossref record.
The Dynamics of Capillary Flow
Abstract
Penetration of Liquids into Cylindrical Capillaries.---The rate of penetration into a small capillary of radius $r$ is shown to be: $\frac{\mathrm{dl}}{\mathrm{dt}}=\frac{P({r}^{2}+4\ensuremath{\epsilon}r)}{8\ensuremath{\eta}l}$, where $P$ is the driving pressure, $\ensuremath{\epsilon}$ the coefficient of slip and $\ensuremath{\eta}$ the viscosity. By integrating this expression, the distance penetrated by a liquid flowing under capillary pressure alone into a horizontal capillary or one with small internal surface is found to be the square root of ($\frac{\ensuremath{\gamma}\mathrm{rt}\ifmmode\cdot\else\textperiodcentered\fi{}cos\ensuremath{\theta}}{2\ensuremath{\eta}}$), where $\ensuremath{\gamma}$ is the surface tension and $\ensuremath{\theta}$ the angle of contact. The quantity ($\frac{\ensuremath{\gamma}cos\ensuremath{\theta}}{2\ensuremath{\eta}}$) is called the coefficient of penetrance or the penetrativity of the liquid.Penetration of Liquids into a Porous Body.---(1) Theory. If a porous body behaves as an assemblage of very small cylindrical capillaries, the volume which penetrates in a time $t$ would be proportional to the square root of ($\frac{\ensuremath{\gamma}t}{\ensuremath{\eta}}$). (2) Experiments with mercury, water and other liquids completely verify the theoretical deductions.Dynamic capillary method of measuring surface tension is described. It possesses certain advantages on the static method of capillary rise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quéré, D. (2008) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.38.060407.132434 · Cited by 2,691
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Recent Developments in the Synthesis of Supported Catalysts
Munnik, P., de Jongh, P. E., & de Jong, K. P. (2015) · Chemical Reviews · doi:10.1021/cr500486u · Cited by 1,528
Quéré, D. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/11/r01 · Cited by 1,249
Acid—base interfacial interactions in aqueous media
van Oss, C. J. (1993) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(93)80308-2 · Cited by 938
Nancollas, G. H., Tang, R., Phipps, R. J., Henneman, Z., Gulde, S., Wu, W., Mangood, A., Russell, R. G. G., & Ebetino, F. H. (2006) · Bone · doi:10.1016/j.bone.2005.05.003 · Cited by 862
Fluid flow in carbon nanotubes and nanopipes
Whitby, M., & Quirke, N. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2006.175 · Cited by 667
Bico, J., Tordeux, C., & Quéré, D. (2001) · Europhysics Letters (EPL) · doi:10.1209/epl/i2001-00402-x · Cited by 650
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
A review of disintegration mechanisms and measurement techniques
Markl, D., & Zeitler, J. A. (2017) · Pharmaceutical Research · doi:10.1007/s11095-017-2129-z · Cited by 439
Injectable, long-acting PLGA formulations: Analyzing PLGA and understanding microparticle formation
Park, K., Skidmore, S., Hadar, J., Garner, J., Park, H., Otte, A., Soh, B. K., Yoon, G., Yu, D., Yun, Y., et al. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.05.003 · Cited by 404
Applications of femtosecond laser induced self‐organized planar nanocracks inside fused silica glass
Taylor, R., Hnatovsky, C., & Simova, E. (2008) · Laser & Photonics Reviews · doi:10.1002/lpor.200710031 · Cited by 345
Huber, P. (2015) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/27/10/103102 · Cited by 322
The effects of hemicelluloses and lignin removal on water uptake behavior of hemp fibers
Pejic, B. M., Kostic, M. M., Skundric, P. D., & Praskalo, J. Z. (2008) · Bioresource Technology · doi:10.1016/j.biortech.2007.12.073 · Cited by 287
Wearable plasmonic paper–based microfluidics for continuous sweat analysis
Mogera, U., Guo, H., Namkoong, M., Rahman, M. S., Nguyen, T., & Tian, L. (2022) · Science Advances · doi:10.1126/sciadv.abn1736 · Cited by 280
The shrinkage of alkali activated fly ash
Ma, Y., & Ye, G. (2015) · Cement and Concrete Research · doi:10.1016/j.cemconres.2014.10.024 · Cited by 275
Evaluation of rapidly disintegrating tablets prepared by a direct compression method
Bi, Y. X., Sunada, H., Yonezawa, Y., & Danjo, K. (1999) · Drug Development and Industrial Pharmacy · doi:10.1081/ddc-100102211 · Cited by 269
Barriers to Superfast Water Transport in Carbon Nanotube Membranes
Walther, J. H., Ritos, K., Cruz-Chu, E. R., Megaridis, C. M., & Koumoutsakos, P. (2013) · Nano Letters · doi:10.1021/nl304000k · Cited by 254
Liu, C., Wang, H., Tang, X., Guan, Z., Reid, B. J., Rajapaksha, A. U., Ok, Y. S., & Sun, H. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-4885-9 · Cited by 175
Cell wall microstructure, pore size distribution and absolute density of hemp shiv
Jiang, Y., Lawrence, M., Ansell, M. P., & Hussain, A. (2018) · Royal Society Open Science · doi:10.1098/rsos.171945 · Cited by 115
Water Confinement in Hydrophobic Nanopores. Pressure-Induced Wetting and Drying
Smirnov, S., Vlassiouk, I., Takmakov, P., & Rios, F. (2010) · ACS Nano · doi:10.1021/nn101080k · Cited by 77
Wetting dynamics of nanoliter water droplets in nanoporous media
Pan, B., Clarkson, C. R., Atwa, M., Debuhr, C., Ghanizadeh, A., & Birss, V. I. (2021) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2020.12.108 · Cited by 50
NIR spectroscopic study of the dissolution process in pharmaceutical tablets
Hattori, Y., & Otsuka, M. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.09.003 · Cited by 41
Cohen, C., Mouterde, T., Quéré, D., & Clanet, C. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1419315112 · Cited by 40
Acoustically-driven thread-based tuneable gradient generators
Ramesan, S., Rezk, A. R., Cheng, K. W., Chan, P. P. Y., & Yeo, L. Y. (2016) · Lab on a Chip · doi:10.1039/c5lc00937e · Cited by 33
Dependence between dissolution rate and porosity of compressed erythromycin acistrate tablets
Riippi, M., Yliruusi, J., Niskanen, T., & Kiesvaara, J. (1998) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(98)00003-4 · Cited by 35
Metadata
- Authors
- Washburn, E. W.
- Venue
- Physical Review
- Publisher
- American Physical Society (APS)
- Published
- 1921-03-01
- Volume
- 17
- Issue
- 3
- Pages
- 273-283
- ISSN
- 0031-899X (ISSN-L)
- OpenAlex
- W2058046601
- Cited by
- 7,141
- References
- 0
- FWCI
- 20.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.