The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A computational model of electrical stimulation of the retinal ganglion cell
Abstract
Localized retinal electrical stimulation in blind volunteers results in discrete round visual percepts corresponding to the location of the stimulating electrode. The success of such an approach to provide useful vision depends on elucidating the neuronal target of surface electrical stimulation. To determine if electrodes preferentially stimulate ganglion cells directly below them or passing fibers from distant ganglion cells, we developed a compartmental model for electric field stimulation of the retinal ganglion cell (RGC). In this model a RGC is stimulated by extracellular electrical fields with active channels and realistic cell morphology derived directly from a neuronal tracing. Three membrane models were applied: a linear passive model, a Hodgkin-Huxley model with passive dendrites (HH), and a model composed of all active compartments (FCM) with five nonlinear ion channels. Idealized monopolar point and disk stimulating electrodes were positioned above the cell. For the HH and FCM models, the position of lowest cathodal threshold to propagate an action potential was over the soma. Brief (100 microseconds) cathodic stimuli were 20% (HH with disk electrode) to 73% (FCM with point-source) more effective over the soma than over the axon. In the passive model, the axon is preferentially stimulated versus the soma. Although it may be possible to electrically stimulate RGC's near their cell body at lower thresholds than at their axon, these differences are relatively small. Alternative explanations should be sought to explain the focal perceptions observed in previously reported patient trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Rattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Cited by
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 867
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationCellular Effects of Deep Brain Stimulation: Model-Based Analysis of Activation and Inhibition
McIntyre, C. C., Grill, W. M., Sherman, D. L., & Thakor, N. V. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00989.2003 · Cited by 818
Neuron: A Tool for Neuroscientists
Hines, M. L., & Carnevale, N. T. (2001) · The Neuroscientist · doi:10.1177/107385840100700207 · Cited by 634
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Self-citationSpatiotemporal dynamics of continuum neural fields
Bressloff, P. C. (2012) · Journal of Physics A: Mathematical and Theoretical · doi:10.1088/1751-8113/45/3/033001 · Cited by 414
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Self-citationThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
Selective Microstimulation of Central Nervous System Neurons
McIntyre, C. C., & Grill, W. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.262 · Cited by 258
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Self-citationCurrent approaches to model extracellular electrical neural microstimulation
Joucla, S., Glière, A., & Yvert, B. (2014) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2014.00013 · Cited by 78
Focal electrical stimulation of human retinal ganglion cells for vision restoration
Madugula, S. S., Gogliettino, A. R., Zaidi, M., Aggarwal, G., Kling, A., Shah, N. P., Brown, J. B., Vilkhu, R., Hays, M. R., Nguyen, H., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca5b5 · Cited by 26
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073130 · Cited by 18
Efficient Modeling and Calibration of Multi-Electrode Stimuli for Epiretinal Implants
Vasireddy, P. K., Gogliettino, A. R., Brown, J. B., Vilkhu, R. S., Madugula, S. S., Phillips, A. J., Mitral, S., Hottowy, P., Sher, A., Litke, A., et al. (2023) · 2023 11th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner52421.2023.10123907 · Cited by 2
“This formulation is consistent with known mechanisms of extracellular activation of neurons [15], [16], as the extracellular voltage and activating function (proportional to the second spatial derivative of the voltage along the direction of the axon) are proportional to the stimulating current, for both the disk and…”
Background
Metadata
- Authors
- Greenberg, R. J., Velte, T. J., Humayun, M. S., Scarlatis, G. N., & De Juan, E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-05
- Volume
- 46
- Issue
- 5
- Pages
- 505-514
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2137213967
- Cited by
- 184
- References
- 2
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.