The DOI matches its Crossref record; 20 of the 24 references it cites were found in a registry or an index.
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
Abstract
A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Campbell et al. 1991
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 355
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
A 100 electrode intracortical array: structural variability.
Campbell, P. K., Jones, K. E., & Normann, R. A. (1990) · PubMed · Cited by 35
Self-citationMercer, H. D., & White, R. L. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326282 · Cited by 33
Flagged first, then by citations
4 of the 24 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
- hahn, 1987, Innovative techniques for protective coatings of neural prosthetic devices Material development and evaluation
- penfield, 1950, The Cerebral Cortex of Man
- de yoe, 1983, An investigation in the awake macaque of the threshold for detection of electrical currents applied to striate cortex Psychophysical properties and laminar differences
Cited by
Sorted by citations
Items 701–800 of 884
Meyer, L. M., & Zamani, M. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae6dfd · Cited by 1
New Applications of Neurotechnologies for Neurological Disorders
Orsborn, A. L., Pirondini, E., Capogrosso, M., Gaunt, R. A., & Stavisky, S. D. (2025) · Springer eBooks · doi:10.1007/978-3-031-89307-0_25 · Cited by 1
Advances in neuroprostheses: interfaces, materials, and applications
He, E., Chen, K., Liu, S., Chen, H., Xiao, Y., Chen, R., Tu, P., Pan, G., & Lin, P. (2026) · Nano Convergence · doi:10.1186/s40580-026-00552-2 · Cited by 1
Yoon, C., Lee, Y., Yim, G., Lee, S.-W., Lee, W., Park, Y.-G., & Park, S. (2026) · ACS Nano · doi:10.1021/acsnano.6c02201 · Cited by 1
Su, J., Wang, H., Han, L., Cheng, R., Hao, R., & Sang, S. (2026) · Journal of Zhejiang University. Science A · doi:10.1631/jzus.a2600114 · Cited by 1
A Microsystem with Varying-Length Electrode Arrays for Auditory Nerve Prostheses
Wu, J. C., Feng, W., Tang, W. C., & Zeng, F. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259698 · Cited by 1
Novel design and fabrication of double side penetrating neural electrode array
Negi, S., Hogan, A. L., Leber, M., Shandhi, M. M. H., & Bhandari, R. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181279 · Cited by 1
Integration of temperature detection onto catheter flow sensor for bronchoscope
Yamazaki, Y., Yoshikawa, K., Shikida, M., Matsushima, M., & Kawabe, T. (2012) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2012.6411097 · Cited by 1
A field-referenced surface electrode for biosignal detection
Eliza, S. A., Paige, A. L., & Haider, M. R. (2014) · International Conference on Electrical and Computer Engineering (ICECE) · doi:10.1109/icece.2014.7026879 · Cited by 1
Review of Microelectrode Fabrication
Liu, P. C., Zhou, J., Li, S. L., & Ma, H. M. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.565.503 · Cited by 1
Implantable micro CMOS imaging devices for biomedical applications
Ohta, J., Noda, T., Sasagawa, K., & Tokuda, T. (2013) · International Conference on Optical MEMS and Nanophotonics · doi:10.1109/omn.2013.6659031 · Cited by 1
Out-of-plane connection in an orthogonal assembly
Ling, T. K., Zhi, D. M., Lei, Y., Yee, T. B., Je, M., & Ming-Yuan, C. (2012) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2012.6507046 · Cited by 1
Zhao, X.-T., Wang, Z., & Lv, X. (2013) · Progress In Electromagnetics Research B · doi:10.2528/pierb13082806 · Cited by 1
Implantable Brain Interface: High-Density Microelectrode Array for Neural Recording
Jun, S. B. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_4 · Cited by 1
Takahashi, H., & Jimbo, Y. (2013) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.133.544 · Cited by 1
Herbawi, A. S., Mildenberger, B., Larramendy, F., Holzhammer, T., Galchev, T., Paul, O., & Ruther, P. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.08.803 · Cited by 1
Micromachined Si and Biodegradable Microneedles for Trans-Dermal Drug Delivery Systems
Shikida, M. (2016) · Journal of the Japan Society for Precision Engineering · doi:10.2493/jjspe.82.1005 · Cited by 1
Integration of Process-Incompatible Materials for Microfabricated Polymer-Based Neural Interfaces
Hess‐Dunning, A. (2011) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
RF powering of micro coils array for wireless spherical particle-based neural probes
Luo, W., Likhite, R., Mastrangelo, C. H., & Young, D. J. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994431 · Cited by 1
Paul, O., & Ruther, P. (2014) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2014.1 · Cited by 1
Multifunctional Freestanding Microprobes for Potential Biological Applications
Yang, N., Wang, Z., Xu, J., Gui, L., Tang, Z., Zhang, Y., Yi, M., Yue, S., & Xu, S. (2019) · Sensors · doi:10.3390/s19102328 · Cited by 1
Next Generation Neural Interface Electronics
Williams, I., Leene, L. B., & Constandinou, T. G. (2022) · River Publishers eBooks · doi:10.1201/9781003337522-7 · Cited by 1
INTRACELLULAR NEURONAL RECORDING WITH FLEXIBLE MICRO-MACHINED PROBE IMPLANTS
Govindarajan, A. V., Tirapelli, D. P. C., Wyeth, R. C., Willows, A. O. D., & Böhringer, K. F. (2004) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2004.47 · Cited by 1
Development of three dimensional neural sensing device by stacking method
Chiou, J., & Chang, C. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690940 · Cited by 1
Anodic-Bonding-Assisted Silicon Microelectrode Array For Neural Applications
Xu, Q., Wang, L., Xi, Y., Guo, Z., Ruan, T., Shi, Y., Yang, B. T., & Liu, J. (2022) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems51670.2022.9699621 · Cited by 1
Microneedle of Biodegradable Polyacid Anhydride with a Capillary Open Groove for Reagent Transfer
Satomitsu, I. M. A. I., CHIDAISYO, K., & Yasuda, K. (2022) · IEICE Transactions on Electronics · doi:10.1587/transele.2022oms0005 · Cited by 1
Electrophysiological Techniques for Studying Tactile Perception in Rats
Öztürk, S., Devecıoğlu, İ., Vardar, B., Duvan, F. T., & Güçlü, B. (2023) · Neuromethods · doi:10.1007/978-1-0716-3068-6_16 · Cited by 1
How Can I Use Utah Arrays for Brain-Computer Interfaces?
Klaes, C. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_51 · Cited by 1
The Function of Cortical Microcircuits: Insights from Biomorphic Ceramic-Based Microelectrode Arrays
Gerhardt, G. A., Opriș, I. C., Burmeister, J. J., Pomerleau, F., Quintero, J. E., Huettl, P. F., Hampson, R. E., & Deadwyler, S. A. (2015) · Springer eBooks · doi:10.1007/978-94-017-9900-3_17 · Cited by 1
The design and fabrication of two-dimension multielectrodes array chip and system
Chen, J., Huang, J.-G., & Lin, C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403702 · Cited by 1
Successive-divider-line ADC dedicated to low-power medical devices
Chebli, R., Hasanuzzaman, M., Haidar, A., & Sawan, M. (2012) · Microelectronics Journal · doi:10.1016/j.mejo.2012.03.010 · Cited by 1
Deep Diffusions and Soi Layers Produced by Rapid Thermal Processing for Smart Power Applications
Dilhac, J.-M., Cornibert, L., & Ganibal, C. (1997) · MRS Proceedings · doi:10.1557/proc-470-319 · Cited by 1
Micromachining Techniques for Realization of Three-Dimensional Microelectrode Arrays
Rajaraman, S. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_5 · Cited by 1
MEMS as implantable neuroprobes
Govindarajan, A. V., Je, M., Park, W., & Achyuta, A. K. H. (2012) · Elsevier eBooks · doi:10.1533/9780857096272.4.359 · Cited by 1
Xie, X. (2014) · PhDT · doi:10.26053/0h-449a-s1g0 · Cited by 1
Parylene-based flexible imaging device for physiological measurement of rodent brain
Yamaguchi, T., Hayami, H., Sunaga, Y., Haruta, M., Noda, T., Sasagawa, K., Tokuda, T., & Ohta, J. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234412 · Cited by 1
Novel Materials for Cellular Nanosensors
Sasso, L. (2012) · Cited by 1
MEMS BASED DRUG DELIVERY SYSTEM USING MICROPUMP
MAHIJA, K., PUSHPALATHA, B. G., & Jijesh, J. J. (2013) · International Journal of Electronics Signals and Systems · doi:10.47893/ijess.2013.1108 · Cited by 1
Alahi, M. E. E., Tian, Z., Khademi, S., Wang, H., & Wu, T. (2021) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems51815.2021.9451468 · Cited by 1
DESIGN, FABRICATION, AND CHARACTERIZATION OF MICROELECTRODES FOR BRAIN-MACHINE INTERFACES By
Patrick, E. E., & Patrick, C. E. (2010) · Cited by 1
Topical and Systemic Drug Delivery Systems for Targeted Therapy
Häfeli, U. O., & Kale, A. A. (2009) · Wiley eBooks · doi:10.1002/9780470522226.ch19 · Cited by 1
Nano-Watt Modular Integrated Circuits for Wireless Neural Interface.
Chang, S.-I. (2013) · Deep Blue (University of Michigan) · Cited by 1
Implantable CMOS Imaging Devices
Ohta, J. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch10 · Cited by 1
Electrical isolation of bulk silicon MEMS devices via thermomigration
Chung, C. C., & Allen, M. G. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2000.838507 · Cited by 1
Application of the Wire Bonding Technology to a Flexible Neural Probe
Shimizu, K., Nakanishi, M., Makikawa, M., Asajima, S., & Konishi, S. (2009) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.129.387 · Cited by 1
Micromachined precision cutting tools
Frazier, A. B. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579816 · Cited by 1
Penetration-Type Microelectrode Array with a Silicone-Rubber Substrate
Suzurikawa, J., Nakao, M., & Takahashi, H. (2007) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.127.1549 · Cited by 1
Polymer-Based Approaches to Improve the Long Term Performance of Intracortical Neural Interfaces
Hassler, C., & Stieglitz, T. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03889-1_32 · Cited by 1
Huang, R. K.-J. (2010) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/vmzb-0n20 · Cited by 1
Development and Characterization of Anti-Inflammatory Coatings for Implanted Neural Probes
Zhong, Y. (2006) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Aplicação de autômatos celulares para simulação de processos de microfabricação.
Colombo, F. B. (2017) · doi:10.11606/t.3.2017.tde-07032017-144709 · Cited by 1
Implantation of Elongated Porous Silicon Neural Probe Array in Rat CortexPreprint
Hajj-Hassan, M., Fayad, R., Berro, S., Chodavarapu, V. P., & Musallam, S. (2018) · Preprints.org · doi:10.20944/preprints201801.0080.v1 · Cited by 1
Fabrication of Hollow Silicon Microneedle Arrays for Transdermal Biological Fluid Extraction
Zhang, H. (2018) · UWSpace (University of Waterloo) · Cited by 1
Muthuswamy, J., Sridharan, A., & Okandan, M. (2016) · Springer eBooks · doi:10.1007/978-94-017-9780-1_303 · Cited by 1
Neuroelectrophysiology-Compatible Electrolytic LesioningPreprint
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2023) · eLife · doi:10.7554/elife.84385.1 · Cited by 1
Neuroelectrophysiology-Compatible Electrolytic LesioningPreprint
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2024) · eLife · doi:10.7554/elife.84385.2 · Cited by 1
Medical Therapy: The Next Frontier of Biochip and Biomedical Nanotechnology
Mauro Ferrari, B., Friend, D. H., Hansford, D. J., Kulkarni, S. S., & Martin, F. (2003) · Springer eBooks · doi:10.1007/978-3-662-05092-7_2 · Cited by 1
Laser cleaning of slotted components
Yue, L. (2013) · Research Explorer (The University of Manchester) · Cited by 1
Analog Front-End Circuits for Massive Parallel 3-D Neural Microsystems.
Al-Ashmouny, K. M. (2013) · Deep Blue (University of Michigan)
Validation of a Cortical Electrode Model for Neuroprosthetics purposes
García-de-Quirós, F. J., Bonomini, M. P., Ferrández, J. M., & Fernández, E. (2003) · Lecture notes in computer science · doi:10.1007/3-540-44869-1_11
Regele, O. B. (2013) · Purdue e-Pubs (Purdue University System)
Regenerative-type neural interface
Valderrama, E., Villa, R., Cabruja, E., Garrido, P., Navarro, X., Butı́, M., & Calvet, S. (1995) · Lecture notes in computer science · doi:10.1007/3-540-59497-3_164
Regenerative Peripheral Neurointerfacing Of Upper Extremity Prostheses
Garde, K. (2008) · UTA ResearchCommons (University of Texas Arlington)
Insect muscle potential recording by an epoxy-based multichannel microelectrode
Kuwana, Y. (2005) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2005.1548489
Chan, A. M. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
Optimization of the thyristor valves design for TCR static VAr compensators
Freire, A. R. F., Soares, G. A., Lima, A. G. G., & Afonso, J. L. (1991) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Penetration‐type microelectrode array with a silicone‐rubber substrate
Suzurikawa, J., Nakao, M., & Takahashi, H. (2009) · Electronics and Communications in Japan · doi:10.1002/ecj.10060
Fabrication of a flexible neural interface device with CMOS-based smart electrodes
Noda, T., Kitao, T., Ito, T., Sasagawa, K., Tokuda, T., Terasawa, Y., Tashiro, H., Kanda, H., Fujikado, T., & Ohta, J. (2011) · IEEE/IFIP International Conference on VLSI and System-on-Chip (VLSI-SoC) · doi:10.1109/vlsisoc.2011.6081608
A multiplexing/demultiplexing system for use with an intracortical electrode array
Jones, K. E., & Normann, R. A. (1992) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1992.5761846
Self-citationA novel 3D neural probe with integrated channel and its package
Fu, X., Xu, Y. P., Li, Y., Zhang, J., Luo, X., & Liu, S. (2014) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2014.6897284
MULTICHANNEL PLANAR MICROELECTRODE ARRAY FOR SOMATIC MAPPING IN RATS
Shaw, F.-Z., Yang, T.-F., Huang, C.-C., Yeh, K.-H., Chang, T.-C., & Leu, F.-J. (2011) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237211002840
Sharp needle tip formation based on triangular pyramidal structure
Imaeda, K., Bessho, K., & Shikida, M. (2014) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2014.6985059
Takei, K., Kawano, T., Kawashima, T., Sawada, K., Kaneko, H., & Ishida, M. (2009) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2009.4805351
Negi, S., Bhandari, R., & Solzbacher, F. (2008) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2008.4550195
Multi channel high aspect ratio glass microelectrode array for neuroprosthetic applications
Negi, S., & Bhandari, R. (2010) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2010.5490734
Development of radio-opaque silicon micro needles for medical diagnostics
Ruiqi, L., Su, N., Chandrappan, J., Tang, S. Q., Vaidyanathan, K., & Nagarajan, R. (2010) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2010.5702611
Mousoulis, C., & Papageorgiou, D. P. (2007) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2007.4388338
Integrated SiO2 microtube-based electrical neuroprobe array
Takei, K., Fujishiro, A., Kawashima, T., Sawada, K., Kaneko, H., Kawano, T., & Ishida, M. (2009) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2009.5285494
High-aspect-ratio Neural Electrode Array Fabrication using Thermomigration Process
Peixoto, A. C., da Silva, A. F., Dias, N. S., & Correia, J. H. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.09.212
Piezo-Driven Vibrating Insertion Device for Microelectrode Array
Noda, T., Kanzaki, R., & Takahashi, H. (2009) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.129.25
Kegley, L. E. (2010) · Journal of the Arkansas Academy of Science
Large-Scale Multiunit Recording Polytrodes: High-Density Silicon Electrode Arrays for
Blanche, T. J., Spacek, M. A., Hetke, J. F., Nicholas, V., Mechler, F., Victor, J. D., Schmid, A., Qin, H., Beckers, G. J. L., Gahr, M. L., et al. (2015)
Biocompatible Hybrid System Integration of Silicon Based Neural Interface Devices
Tathireddy, P., Chakravarthy, S., Jui-Mei, H., Klein, M., Oppermann, H. H., Rieth, L. W., Harrison, R. R., Normann, R. A., & Solzbacher, F. (2006) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft)
Self-citationFabrication of Biocompatible Microstructures to Support Tissue Regeneration
Ayala, P. (2011) · eScholarship (California Digital Library)
Hess‐Dunning, A. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
Microneedle Array Fabrication based on Thermomigration
Peixoto, A. C., Silva, A. F., Dias, N. S., & Correia, J. H. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.13140/2.1.3528.5121
SILICON MICROELECTRODE ARRAYS FOR IN SITU ENVIRONMENTAL MONITORING
Wei, X. (2005) · OhioLink ETD Center (Ohio Library and Information Network)
Motor output-type Brain-Machine Interface
Suzuki, T. (2012) · The Brain & Neural Networks · doi:10.3902/jnns.19.112
Biomedical Devices based on Semiconductor Microelectronics Technologies
Ohta, J., Kobayashi, T., Noda, T., Sasagawa, K., & Tokuda, T. (2011) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.131.404
Estimation of Movement by Epidural Potential Measurement
Uejima, T., Fujii, T., Kato, R., Takita, M., & Yokoi, H. (2011) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.27.732
An SMA Microelectrode for Insect Neural Recording
Takeuchi, S., & Shimoyama, I. (1999) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.119.641
CMOS technology: a critical enabler for free-form electronics-based killer applications
Hussain, M. M., Hussain, A. M., & Hanna, A. N. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2222972
Reducing the implant footprint: low-area neural recording
Muller, R., Gambini, S., & Rabaey, J. M. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.035
Brain–Machine Interface and Rehabilitation
Pham, M. H., Taghva, A. S., & Rezai, A. R. (2013) · CRC Press eBooks · doi:10.1201/b15274-34
Chung, C. C. (2004) · UPT. Syiah Kuala University Library (Syiah Kuala University)
Metadata
- Authors
- Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 8
- Pages
- 758-768
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111937020
- Cited by
- 881
- References
- 24
- Citations by year
- 2026: 21 · 2025: 29 · 2024: 41 · 2023: 24 · 2022: 35 · 2021: 32 · 2020: 40 · 2019: 39 · 2018: 34 · 2017: 41 · 2016: 36 · 2015: 41 · 2014: 43 · 2013: 56 · 2012: 41
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- neural interfaces, thermomigration, p+ silicon, micromachining, platinum coating, polyimide encapsulation, monocrystalline silicon substrate, galvanic isolation
- MeSH terms
- Animals, Biocompatible Materials, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Materials Testing, Microscopy, Electron, Scanning, Silicon, Somatosensory Cortex, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review