The DOI matches its Crossref record; 20 of the 24 references it cites were found in a registry or an index.
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
Abstract
A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Campbell et al. 1991
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 355
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
A 100 electrode intracortical array: structural variability.
Campbell, P. K., Jones, K. E., & Normann, R. A. (1990) · PubMed · Cited by 35
Self-citationMercer, H. D., & White, R. L. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326282 · Cited by 33
Flagged first, then by citations
4 of the 24 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
- hahn, 1987, Innovative techniques for protective coatings of neural prosthetic devices Material development and evaluation
- penfield, 1950, The Cerebral Cortex of Man
- de yoe, 1983, An investigation in the awake macaque of the threshold for detection of electrical currents applied to striate cortex Psychophysical properties and laminar differences
Cited by
Sorted by citations
Items 801–884 of 884
Takahashi, H., Ejiri, T., Nakao, M., Nakamura, N., Kaga, K., & Hervé, T. (2002) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss1987.122.9_1459
Development of Stable Long‐term Electrode Tissue Interfaces for Recording and Stimulation
Schouenborg, J. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch2
Bonfanti, A. G., Borghi, T., Zambra, G., & Lacaita, A. L. (2011) · Wiley eBooks · doi:10.1002/9781118016497.ch2
Multimodal, Multisite Neuronal Recordings for Brain Research
Hofmann, U., Detemple, P., & Xie, Y. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch5
Wu, F. (2015) · Deep Blue (University of Michigan)
Epoxy-Based Multichannel Microelectrode for Insect Biopotential Recording
Kuwana, Y. (2006) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2006.p0499
Multi-channel Neural Signal Recording System toward Brain Science and Clinical Applications
Ando, H. (2015) · The Brain & Neural Networks · doi:10.3902/jnns.22.170
Strategies for developing ultrathin, high-density, actively multiplexed neural mapping device
Kim, Y. (2012) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Flexible and foldable single-crystalline silicon electronics for various applications
Lee, Y. R. (2014) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Barnes, A. (2011) · OhioLink ETD Center (Ohio Library and Information Network)
A neurospheroid cultured on the tip of a flexible microelectrode for cortical microstimulation
Okita, K., Kato‐Negishi, M., Sato, K., Onoe, H., & Takeuchi, S. (2012) · International Conference on Miniaturized Systems for Chemistry and Life Sciences (MicroTAS)
Murphy, S. J. (2012) · OhioLink ETD Center (Ohio Library and Information Network)
Nolta, N. F. (2018) · J. Willard Marriott Library · doi:10.26053/0h-sqbe-9pg0
Investigation of Implantable Multichannel Neurostimulators
Kumar, Y. N. (2015)
Neural Recording System for Brain-Machine Interface
Suzuki, T. (2017) · Journal of the Japan Society for Precision Engineering · doi:10.2493/jjspe.83.996
Electrode Array for Neural Interfaces
Pei, W., & Chen, H. (2017) · Toxinology · doi:10.1007/978-981-10-2798-7_42-1
Cunningham, J. M. (2017) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3mk65n9h
Tazrin, F. (2019) · UWSpace (University of Waterloo)
Muthuswamy, J., Sridharan, A., & Okandan, M. (2016) · Springer eBooks · doi:10.1007/978-94-007-6178-0_303-2
Fiber-based pumpless flexible drug delivery system for implantable prosthesis
변재환 (2014) · Seoul National University Open Repository (Seoul National University)
Long Porous Silicon Probe Array for Neural Recordings
Hajj-Hassan, M. (2020) · Archives in Neurology & Neuroscience · doi:10.33552/ann.2020.08.000678
Neural Interface Devices: Connecting Electronics to the Brain
Kawano, T. (2020) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.140.668
Microinstrument for Transdermal, Woundpotential Measurements
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., Nuccitelli, R., & Smith, R. L. (2000) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2000a.5
Stieglitz, T. (2021) · Springer eBooks · doi:10.1007/978-3-030-68545-4_14
Beygi, M. (2020) · Digital Commons - University of South Florida (University of South Florida)
Hasegawa, Y., Noma, H., Matsushima, M., Hasegawa, S., Kawabe, T., & Shikida, M. (2021) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.142.2
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_16-2
Robinson, C. J. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-0122-2.ch016
Zjajo, A. (2016) · Springer eBooks · doi:10.1007/978-3-319-31541-6_1
Muthuswamy, J., & Okandan, M. (2012) · Springer eBooks · doi:10.1007/978-90-481-9751-4_303
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9_7
Forming Tip Electrodes on 3D Neural Probe Arrays Using Electroplated Photoresist
Rostami, B., & Najafi, K. (2022) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors52175.2022.9967356
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_16
eLife Assessment: Neuroelectrophysiology-Compatible Electrolytic Lesioning
Behrens, T. E. J. (2023) · eLife · doi:10.7554/elife.84385.1.sa3
Author Response: Neuroelectrophysiology-Compatible Electrolytic Lesioning
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2023) · eLife · doi:10.7554/elife.84385.1.sa0
Modeling and characterization of LiNbO3-based microring resonator modulator for synaptic sensing
Babayiğit, C., Esfandyarpour, R., & Boyraz, O. (2024) · Label-free Biomedical Imaging and Sensing (LBIS) · doi:10.1117/12.3002839
Metallic Microneedle Electrode Array (m-MNEA) as a Novel Intracortical Neural Interface
Li, J., Wang, Z., Shi, X., Huang, D., Zheng, Y., & Li, Z. (2024) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems60219.2024.10639853
Advanced Fibers for Optogenetic Modulation
Du, M., & Zhou, S. (2024) · Wiley eBooks · doi:10.1002/9783527839322.ch7
Brain–Machine Interface and Rehabilitation
Ranjan, M., Pham, M. H., Taghva, A. S., Konrad, P. E., & Rezai, A. R. (2024) · Springer eBooks · doi:10.1007/978-3-030-80662-0_31
Stoeber, B. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00023-6
Advances in neural information detection sensors for spatial cognition research: A review
Wang, M., Lv, S., Wang, Y., Xu, Z., Jiao, P., Liu, Y., Zhang, S., Wu, Y., Wang, M., Luo, J., et al. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100274
Basic Study of a Method for Supplying Drugs by Making Microneedles Warmed by Ultrasonic Heating
Satomitsu, I. M. A. I., Ishii, S., & ITAYA, N. (2024) · IEICE Transactions on Electronics · doi:10.1587/transele.2024oms0001
Material Damage to Multielectrode Arrays after Electrolytic Lesioning is in the NoisePreprint
Tor, A., Clarke, S. E., Bray, I. E., & Nuyujukian, P. (2025) · eLife · doi:10.7554/elife.106452.1
Soft Sensors for Disease Diagnosis
Hu, H., Su, Y., & Nan, K. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch3
Flexible Electrodes: Catalyzing Commercial Revolution of Brain–Computer Interfaces
Cai, R., Chen, D., Dong, L., & Hu, B. (2025) · IEEE Transactions on Computational Social Systems · doi:10.1109/tcss.2025.3606586
Zhou, J. J., Mukerjee, E. V., Jackson, K. J., Sahota, S. S., Hernandez, J. J., Ivanovskaya, A. N., Lawlor, G. L., Koliatsos, V. E., & Yorita, A. M. (2025) · IEEE BioSensors Conference (BioSensors) · doi:10.1109/biosensors65002.2025.11239322
Experimental Methods and Setup
Feng, Z. (2025) · Springer eBooks · doi:10.1007/978-981-95-4145-4_3
Application of polyimides in implants
Yang, X., Ma, W., Liu, H., Tang, W., Shu, J., Zheng, H., Zhou, Z., Chen, Y., & Liang, H. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-29911-7.00005-9
Optimized Single‐Shank Silicon Neural Probe for Neural Recording in Non‐Human Primates
Cao, J., Wang, L., Chen, H., Wang, R., Xu, Q., Xu, M., Yin, J., Wang, X., Yang, B., & Liu, J. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501356
Miniaturized Foldable Electrodes with Direct CMOS Integration for Implantable Applications
Qian, J., Coronese, M., Pafundo, A., Meimandi, A., Barbruni, G. L., Carminati, M., & Carrara, S. (2025) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas67066.2025.00084
Pareto-optimization of hypodermic needles with respect to flow, buckling and piercing
Humer, A., Ehrenhofer, A., Wallmersperger, T., & Krommer, M. (2026) · Acta Mechanica · doi:10.1007/s00707-025-04543-y
Material Damage to Multielectrode Arrays after Electrolytic Lesioning is in the NoisePreprint
Tor, A., Clarke, S. E., Bray, I. E., & Nuyujukian, P. (2026) · eLife · doi:10.7554/elife.106452.2
Microelectromechanical systems (mems) for drug delivery: A detailed Review
Ingle, S., Shinde, K., & Kurulkar, A. (2025) · International Journal of Technology · doi:10.52711/2231-3915.2025.00015
Overview of the Brain-Computer Interface Industry
Li, W., Zhou, J., Zhang, Q., Liang, L.-Y., Cheng, L., & Chun-jia, W. (2025) · Journal of Brain-Computer Interface · doi:10.58195/bci.2025.1.002
Development of a selective and energy-autonomous lactic acid monitoring system
Lin, S.-H. (2024) · theses.fr (ABES) · doi:10.70675/4cf84d2cz15b0z4e58z8e1fz23980ac846ec
An advanced TMR sensor-based magnetrode for in vivo LFP magnetic field recording
Wang, Y., Luo, J., Zhang, C., Jin, Z., Wang, M., Xu, Z., Cai, X., & Chen, J. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01262-9
Tor, A., Clarke, S. J., Bray, I. E., & Nuyujukian, P. (2026) · eLife · doi:10.7554/elife.106452.3.sa2
Electronics with switchable flexibility for 3D conforming neural interfaces
He, X., Chamberlin, M., Chen, Z. W., Li, J., Gao, Y., Guo, F., Ma, Y., Wei, X., Luo, X., Zhang, W., et al. (2026) · Science Advances · doi:10.1126/sciadv.aee2752
Flexible E-textile electrodes for human-machine interfaces
Wang, J., Zhang, R., Pan, M., Huang, L., Li, Z., Liu, Y., Wang, X., Kuang, C., Xie, R., Wang, X., et al. (2026) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2026.101270
3D-printed penetrating neural probes with maskless metallization and encapsulation
Sedighi, A., Hasan, M., Feng, X., & Xu, Y. (2026) · Additive Manufacturing Letters · doi:10.1016/j.addlet.2026.100408
Intracortical Microstimulation in Brain–Computer Interfaces: Evoking Perception and Plasticity
Hu, P., Chen, C., Zang, Y., Li, X., & Dong, M. I. N. G. (2026) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0690
Won, S., Boyadzhiev, A. M., Zhou, Q., 박준서, Fan, Y., Huang, S., Lim, T., & Zhang, H. (2026) · ACS Sensors · doi:10.1021/acssensors.6c02036
Optimization of the meso-wedge superconducting sample, for a diode effect in the Meissner
Aguirre, C. A., de Arruda, A. S., Gomez, C., Laroze, D., Diaz, J., & Barba-Ortega, J. (2026) · Modern Physics Letters B · doi:10.1142/s0217984926502398
Thermoplastic polyurethane as a base material for soft, high-density neural interfacesPreprint
Pak, A., Velea, A. I., Hosman, T., Wilson, J., Panskus, R., Seckel, M., Dardagan, P. D. A., Schmidt, R., Horváth, D., Tóth, K., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.04.755411
The Development and Evolution of Substrate Materials for Brain–Computer Interfaces
Ji, J., Gao, Y., Liu, J., Tian, M., & Wei, Y. (2026) · Polymers · doi:10.3390/polym18202569
Generalizable neural decoding for clinically scalable brain-computer interfaces
Gu, Y., Yin, H., Wang, Y., Woon, Y.-Q.-V., Wang, Y., Teng, M., Lu, C., Lü, Z., & Chen, J. (2026) · npj Biomedical Innovations. · doi:10.1038/s44385-026-00119-0
Huang, Y., Cao, J., Wang, X., You, X., Bai, R., Li, M., Hong, Y., Chang, H., Zhao, H., Wang, M., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/aeb97d
Yamada, S. (n.d.) · Institutional Repositories DataBase (IRDB)
Conducting polymers for implantable neural electrodes in brain–computer interfaces
Zhu, J., Liu, R., Jiang, H., Liu, X., Kong, Z., Wang, L., Xu, W., & Wang, Y. (2026) · Journal of Materials Chemistry B · doi:10.1039/d6tb01636g
Functional readouts of neural organoids
Lo, C., Kiral, F. R., & Park, I. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00507-6
Bogdan, M., & Bensch, M. (2006)
Bioanalyses Using Electrochemical and Electrophysiological Methods
Tamiya, E., Mabuchi, K., Yokoyama, K., Murakami, Y., Kobayashi, M., Suzuki, M., Suzuki, H., Suzuki, T., & Kunimoto, M. (2004) · Biological and medical physics series · doi:10.1007/978-3-662-06081-0_4
Metadata
- Authors
- Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 8
- Pages
- 758-768
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111937020
- Cited by
- 881
- References
- 24
- Citations by year
- 2026: 21 · 2025: 29 · 2024: 41 · 2023: 24 · 2022: 35 · 2021: 32 · 2020: 40 · 2019: 39 · 2018: 34 · 2017: 41 · 2016: 36 · 2015: 41 · 2014: 43 · 2013: 56 · 2012: 41
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- neural interfaces, thermomigration, p+ silicon, micromachining, platinum coating, polyimide encapsulation, monocrystalline silicon substrate, galvanic isolation
- MeSH terms
- Animals, Biocompatible Materials, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Materials Testing, Microscopy, Electron, Scanning, Silicon, Somatosensory Cortex, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review