The DOI matches its Crossref record; 20 of the 24 references it cites were found in a registry or an index.
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
Abstract
A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Campbell et al. 1991
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 355
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
A 100 electrode intracortical array: structural variability.
Campbell, P. K., Jones, K. E., & Normann, R. A. (1990) · PubMed · Cited by 35
Self-citationMercer, H. D., & White, R. L. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326282 · Cited by 33
Flagged first, then by citations
4 of the 24 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
- hahn, 1987, Innovative techniques for protective coatings of neural prosthetic devices Material development and evaluation
- penfield, 1950, The Cerebral Cortex of Man
- de yoe, 1983, An investigation in the awake macaque of the threshold for detection of electrical currents applied to striate cortex Psychophysical properties and laminar differences
Cited by
Sorted by citations
Items 401–500 of 884
A self-testing multiplexed CMOS stimulating probe for a 1024-site neural prosthesis
Yao, Y., Gulari, M. N., Hetke, J. F., & Wise, K. D. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216990 · Cited by 15
A customizable multi-channel stimulator for cortical neuroprosthesis
Ferrandez, J. M., Liano, E., Bonomini, P., Martinez, J. J., Toledo, J., & Fernandez, E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353390 · Cited by 14
Flexible and Soft Materials and Devices for Neural Interface
Castagnola, E., Zheng, X. S., & Cui, X. T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_5 · Cited by 15
Design, Fabrication and Analysis of Silicon Microneedles for Transdermal Drug Delivery Applications
Bodhale, D. W., Nisar, A., & Afzulpurkar, N. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12020-6_21 · Cited by 14
Seok, S., Park, H., & Kim, J. (2020) · Micromachines · doi:10.3390/mi11060605 · Cited by 14
Gaunt, R. A., Bruns, T. M., Crammond, D. J., Tomycz, N. D., Moossy, J. J., & Weber, D. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091655 · Cited by 14
Takei, K., Kawano, T., Kawashima, T., Sawada, K., Kaneko, H., & Ishida, M. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9356-y · Cited by 14
Thermomigration-Based Junction Isolation of Bulk Silicon MEMS Devices
Chung, C. C., & Allen, M. G. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.879685 · Cited by 14
Hybrid microprobes for chronic implantation in the cerebral cortex
Kisban, S., Janssen, P., Herwik, S., Stieglitz, T., Paul, O., & Ruther, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649586 · Cited by 14
Blais-Roberge, M., Rioux, M., Ledemi, Y., & Messaddeq, Y. (2017) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2017.04.046 · Cited by 14
Highly inclined electrodeposited metal lines using an excimer laser patterning technique
Choi, Y., Choi, S., Shafer, R. H., & Allen, M. G. (2005) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2005.1497360 · Cited by 14
Smart electrode array device with CMOS multi-chip architecture for neural interface
Noda, T., Sasagawa, K., Tokuda, T., Terasawa, Y., Tashiro, H., Kanda, H., Fujikado, T., & Ohta, J. (2012) · Electronics Letters · doi:10.1049/el.2012.2784 · Cited by 14
Heterostructured IrO2/Au Nanowire Electrodes and Unit Recordings From Hippocampal Rat Brain
Yoon, H., Hankins, P. T., Oh, S., Harbaugh, R. E., & Varadan, V. K. (2010) · Journal of Nanotechnology in Engineering and Medicine · doi:10.1115/1.4001539 · Cited by 14
Design and fabrication of a microelectrode array dedicated for cortical electrical stimulation
Pigeon, S., Michel Meunier, A., Sawan, M., & Martel, S. M. (2004) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2003.1226019 · Cited by 14
Effects of electrode size on the performance of neural recording microelectrodes
Hughes, M. P., Bustamante, K. D., Banks, D., & Ewins, D. J. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893776 · Cited by 14
Active Pixel Sensor Multielectrode Array for High Spatiotemporal Resolution
Berdondini, L., Bosca, A., Nieus, T. R., & Maccione, A. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_7 · Cited by 14
Experimental investigation on surface wettability of copper-based dry bioelectrodes
Zhou, W., Liu, W., Liu, S., Zhang, G., & Shen, Z. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.04.044 · Cited by 13
Grani, F., Soto‐Sánchez, C., Farfán, F. D., Alfaro, A., Grima, M. D., Doblado, A. R., & Fernández, E. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac801d · Cited by 15
T-DOpE probes reveal sensitivity of hippocampal oscillations to cannabinoids in behaving mice
Kim, J., Huang, H., Gilbert, E. T., Arndt, K. C., English, D. F., & Jia, X. (2024) · Nature Communications · doi:10.1038/s41467-024-46021-4 · Cited by 14
Investigation of a New Electrode Array Technology for a Central Auditory Prosthesis
Calixto, R., Salamat, B., Rode, T., Hartmann, T., Volckaerts, B., Ruther, P., Lenarz, T., & Lim, H. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082148 · Cited by 13
Real-time visuomotor behavior and electrophysiology recording setup for use with humans and monkeys
Haan, M. D., Brochier, T. G., Grün, S., Riehle, A., & Barthélemy, F. V. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00262.2017 · Cited by 14
Electrodes for the Neural Interface
Tyler, D. J., & Polasek, K. H. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00018-5 · Cited by 14
Feedforward amplification in recurrent networks underlies paradoxical neural codingPreprint
Daie, K., Fontolan, L., Druckmann, S., & Svoboda, K. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.04.552026 · Cited by 16
Suzuki, M., Sawa, T., Takahashi, T., & Aoyagi, S. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353754 · Cited by 12
Ultra-high-density in-vivo neural probes
Yazicioglu, F., López, C. M., Mitra, S., Raducanu, B., Musa, S., & Kloosterman, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944015 · Cited by 12
Development of spear-shaped microneedle and applicator for tip insertion into artificial skin
Sakamoto, M., Hasegawa, Y., & Shikida, M. (2021) · Microsystem Technologies · doi:10.1007/s00542-020-05195-9 · Cited by 12
Xie, X., Rieth, L. W., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035003 · Cited by 12
Implantable and Flexible Electronics for In vivo Brain Activity Recordings
Wang, J., Tian, H., & Fang, Y. Z. (2019) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(19)61192-8 · Cited by 12
An Implantable Cranial Window Using a Collagen Membrane for Chronic Voltage-Sensitive Dye Imaging
Kunori, N., & Takashima, I. (2019) · Micromachines · doi:10.3390/mi10110789 · Cited by 12
UV–NIR femtosecond laser hybrid lithography for efficient printing of complex on-chip waveguides
Hou, Z., Cao, J., Yu, F., Tian, Z., Xiong, X., Li, M., Ren, X., Chen, Q., & Sun, H. (2020) · Optics Letters · doi:10.1364/ol.386861 · Cited by 12
Laser Sharpening of Carbon Fiber Microelectrode Arrays for Brain Recording
Dong, T., Chen, L., & Shih, A. J. (2020) · Journal of Micro and Nano-Manufacturing · doi:10.1115/1.4049780 · Cited by 12
A Flexible Base Electrode Array for Intraspinal Microstimulation
Khaled, I., Elmallah, S., Cheng, C., Moussa, W. A., Mushahwar, V. K., & Elias, A. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2265877 · Cited by 12
Development of implantable catheter flow sensor into inside of bronchi for laboratory animal
Shikida, M., Matsuyama, T., Yamada, T., Matsushima, M., & Kawabe, T. (2015) · Microsystem Technologies · doi:10.1007/s00542-015-2663-8 · Cited by 12
Du, M., Xu, X., Yang, L., Guo, Y., Guan, S., Shi, J., Wang, J., & Fang, Y. Z. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.027 · Cited by 12
A highly flexible manufacturing technique for microelectrode array fabrication
Fofonoff, T., Martel, S. M., Wiseman, C., Dyer, R., Hunter, I. W., Hatsopoulos, N. G., & Donoghue, J. P. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053191 · Cited by 12
Skin insertion analysis of microneedle using ANSYS and fuzzy logic
Tayyaba, S., Ashraf, M. W., Tariq, M. I., Nazir, M., Afzulpurkar, N., Bǎlaş, M. M., & Mihalache, S. F. (2020) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-179676 · Cited by 11
Lomov, A. A., Пунегов, В. И., & Seredin, B. M. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576721001473 · Cited by 11
Neural Electrode Array Based on Aluminum: Fabrication and Characterization
Peixoto, A. C., Gonçalves, S. B., da Silva, A. F., Dias, N. S., & Correia, J. H. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2270034 · Cited by 11
Wafer Level Processing of Silicon Arrays for Implantable Medical Devices
Bhandari, R., Negi, S., Rieth, L. W., Topper, M. J., Normann, R. A., & Solzbacher, F. (2007) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2007.374004 · Cited by 11
Self-citationA novel mask-less method of fabricating high aspect ratio microneedles for blood sampling
Bhandari, R., Negi, S., & Solzbacher, F. (2008) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2008.4550144 · Cited by 11
Microelectrode Designs for Oxidase-Based Biosensors
Marinesco, S., & Frey, O. (2013) · Neuromethods · doi:10.1007/978-1-62703-370-1_1 · Cited by 11
Characterization of basket-forceps-type micro-flow-sensor for breathing measurements in small airway
Harada, N., Hasegawa, Y., Ono, R., Matsushima, M., Kawabe, T., & Shikida, M. (2017) · Microsystem Technologies · doi:10.1007/s00542-016-3265-9 · Cited by 11
Microelectrode Arrays: Architecture, Challenges and Engineering Solutions
Khudhair, D., Nahavandi, S., Garmestani, H., & Bhatti, A. (2017) · Series in bioengineering · doi:10.1007/978-981-10-3957-7_2 · Cited by 11
Shandhi, M. M. H., & Negi, S. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3004847 · Cited by 13
Material–tissue interfaces in implantable systems
Stieglitz, T., & Schüettler, M. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.1.39 · Cited by 11
Design, Simulation and Fabrication of Silicon Microneedles for Bio-Medical Applications
Ashraf, M. W., Tayyaba, S., Afzulpurkar, N., Nisar, A., Bohez, E. L. J., Lomas, T., & Tuantranont, A. (2010) · ECTI Transactions on Electrical Engineering Electronics and Communications · doi:10.37936/ecti-eec.201191.172302 · Cited by 11
Fully-implantable auditory prostheses: restoring hearing to the profoundly deaf
Wise, K. D., & Najafi, K. (2003) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2002.1175889 · Cited by 11
Development of a wireless brain implant: the Telemetric Electrode Array System (TEAS) project
Martel, S. M., Hatsapoulos, N., Hunter, I. W., Donoghue, J. P., Burgert, J., Malasek, J., Wiseman, C., & Dyer, R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1019612 · Cited by 11
CMU Array: A 3D Nano-Printed, Customizable Ultra-High-Density Microelectrode Array PlatformPreprint
Saleh, M. S., Ritchie, S. M., Nicholas, M. A., Bezbaruah, R., Reddy, J. W., Chamanzar, M., Yttri, E. A., & Panat, R. P. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/742346 · Cited by 11
Slippery Epidural ECoG Electrode for High-Performance Neural Recording and Interface
Alahi, M. E. E., Liu, Y., Khademi, S., Nag, A., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2022) · Biosensors · doi:10.3390/bios12111044 · Cited by 10
Xu, Q., Wang, L., Xi, Y., Ruan, T., Cao, J., Xu, M., Zheng, K., Du, Z., Wei, N., Wang, X., et al. (2025) · Small · doi:10.1002/smll.202407950 · Cited by 10
In vivo validation of the electronic depth control probes
Dombovári, B., Fiáth, R., Kerekes, B. P., Tóth, E., Wittner, L., Horváth, D., Seidl, K., Herwik, S., Torfs, T., Paul, O., et al. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-0102 · Cited by 10
Kim, K., Sung, C., Lee, J., Won, J., Jeon, W., Seo, S., Yoon, K., & Park, S. (2021) · Micromachines · doi:10.3390/mi12040394 · Cited by 12
Cha, J.-H., Park, J.-H., Park, Y., Shin, H., Hwang, K. S., Cho, I., & Kim, S. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3211275 · Cited by 10
Iapichino, M., Maïbach, H. I., & Stoeber, B. (2023) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2023.122885 · Cited by 10
Vinayakumar, K. B., Silva, M. D., Martins, A. J., Mundy, S., González‐Losada, P., & Sillankorva, S. (2023) · Advanced Therapeutics · doi:10.1002/adtp.202200320 · Cited by 10
Novel method for a flexible double-sided microelectrode fabrication process
Doerge, T., Kammer, S., Hanauer, M., Sossalla, A., & Steltenkamp, S. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.821649 · Cited by 11
Hybrid laser and reactive ion etching of Parylene-C for deinsulation of a Utah electrode array
Yoo, J.-M., Song, J.-I., Tathireddy, P., Solzbacher, F., & Rieth, L. W. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/10/105036 · Cited by 10
Hess‐Dunning, A., Tyler, D. J., Harris, J. P., Capadona, J. R., Weder, C., Rowan, S. J., & Zorman, C. A. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2327035 · Cited by 10
Harris, A. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd897 · Cited by 10
Tagawa, A., Mitani, M., Minami, H., Noda, T., Sasagawa, K., Tokuda, T., & Ohta, J. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.04dl02 · Cited by 10
Imtiaz, A. M., Khan, F., & Walling, J. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2354397 · Cited by 10
Development of Si Double-Sided Microelectrode for Platform of Brain Signal Processing System
Kobayashi, R., Kanno, S., Sanghoon, L., Bea, J., Fukushima, T., Sakamoto, K., Katayama, N., Mushiake, H., Tanaka, T., & Koyanagi, M. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.04c194 · Cited by 10
A polymer based electrode array for recordings in the cerebellum
Ejserholm, F., Kohler, P., Bengtsson, M., Jörntell, H., Schouenborg, J., & Wallman, L. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910565 · Cited by 10
Kim, S., Badi, A. N., & Normann, R. A. (2007) · The Laryngoscope · doi:10.1097/mlg.0b013e31804714a7 · Cited by 10
Self-citationKawaoka, H., Yamada, T., Matsushima, M., Kawabe, T., Hasegawa, Y., & Shikida, M. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2707594 · Cited by 10
Chiaranairungroj, M., Pimpin, A., & Srituravanich, W. (2017) · Micro & Nano Letters · doi:10.1049/mnl.2017.0596 · Cited by 10
An Actuated Neural Probe Architecture for Reducing Gliosis-Induced Recording Degradation
Massey, T. L., Kuo, L. S., Fan, J. L., & Maharbiz, M. M. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2905468 · Cited by 10
A Micro-tool for Mechanical Manipulation of in vitro Cell Arrays
Baldi, A., Fass, J., Silva, M. N. D., Odde, D. J., & Ziaie, B. (2003) · Biomedical Microdevices · doi:10.1023/a:1027353612618 · Cited by 10
Neural Signal Sampling via the Low Power Wireless Pico System
Cieslewski, G., Cheney, D. J., Gugel, K., Sanchez, J. C., & Príncipe, J. C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260506 · Cited by 10
Neuroelectrophysiology-compatible electrolytic lesioning
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2023) · eLife · doi:10.7554/elife.84385 · Cited by 9
Spatially Precise Genetic Engineering at the Electrode‐Tissue Interface
Xu, K., Yang, Y., Ding, J., Wang, J., Fang, Y. Z., & Tian, H. (2024) · Advanced Materials · doi:10.1002/adma.202401327 · Cited by 9
Kopic, I., Hu, P., Schmidt, S. W., Berezin, O., Wang, S., Westmeyer, G. G., & Wolfrum, B. L. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03740 · Cited by 9
Flexible kirigami microelectrode arrays for neuronal activity recordings in non-human primate brains
FANG, R., Tian, H., Du, Y., Zhao, Y., Yang, Y., Guan, S., Li, S., Liu, M., Xu, K., & Fang, Y. W. (2026) · Nature Electronics · doi:10.1038/s41928-025-01560-6 · Cited by 9
Three dimensional ALD of TiO2 for in-vivo biomedical sensor applications
Schroder, S., Dogan, Ö., Schneidewind, J., Bertotti, G., Keil, S., Gargouri, H., Arens, M., Brose, E., Bruns, J., Wolansky, D., et al. (2015) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2015.7184978 · Cited by 9
A novel MEMS elastic-based dry electrode for electroencephalography measurement
Yuan, T., Chen, D., Chen, J., Chen, X., Wang, X., & Lu, B. (2013) · Microsystem Technologies · doi:10.1007/s00542-013-1799-7 · Cited by 9
Shin, Y.-M., Kim, Y.-K., Lee, S.-K., Shin, H., Cho, I., & Park, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.03.143 · Cited by 9
Rocca, A., Lehner, C., Wekesa, E., Luna, E., Fernández-Cornejo, V., Abarca-Olivas, J., Soto‐Sánchez, C., Fernández-Jover, E., & González-López, P. (2023) · Journal of neurosurgery · doi:10.3171/2023.8.jns23772 · Cited by 9
Tayyaba, S., Ashraf, M. W., & Afzulpurkar, N. (2013) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2012.2230166 · Cited by 9
Maeng, B.-R., Nam, K.-T., Lee, S.-K., & Park, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.039 · Cited by 9
Ice coating –A new method of brain device insertion to mitigate acute injuries
Mohammed, M., Thelin, J., Gällentoft, L., Thorbergsson, P. T., Kumosa, L. S., Schouenborg, J., & Pettersson, L. M. E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108842 · Cited by 9
Velasco, V., Soucy, P. A., Keynton, R. S., & Williams, S. J. (2022) · Lab on a Chip · doi:10.1039/d2lc00555g · Cited by 9
3D flexible multichannel probe array
Takeuchi, S., Suzuki, T., Mabuchi, K., & Fujita, H. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2003.1189762 · Cited by 9
Etching optimization of post aluminum-silicon thermomigration process residues
Lu, B., Gautier, G., Valente, D., Morillon, B., & Alquier, D. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2015.10.004 · Cited by 9
Gabran, S. R. I., Salam, M. T., Dian, J. A., El-Hayek, Y. H., Velázquez, J. L. P., Genov, R., Carlen, P. L., Salama, M. M. A., & Mansour, R. R. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279403 · Cited by 9
Design, modeling and simulation of MEMS-based silicon Microneedles
Amin, F., & Ahmed, S. S. (2013) · Journal of Physics Conference Series · doi:10.1088/1742-6596/439/1/012049 · Cited by 9
Human faces detection and localization with simulated prosthetic vision
Denis, G., Jouffrais, C., Vergnieux, V., & Macé, M. J. ‐. (2013) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/2468356.2468368 · Cited by 10
Analysis of MEMS-Based Microneedles for Blood Monitoring
Ganesan, A., Kumar, H., Swaminathan, S., Singh, K. K., Joy, R. A., Sood, N., Gokhale, T., & Mittal, R. K. (2014) · BioNanoScience · doi:10.1007/s12668-013-0122-5 · Cited by 9
Development of Si Neural Probe with Microfluidic Channel Fabricated Using Wafer Direct Bonding
Kanno, S., Kobayashi, R., Lee, S., Bea, J., Fukushima, T., Sakamoto, K., Katayama, N., Mushiake, H., Tanaka, T., & Koyanagi, M. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.04c189 · Cited by 9
High-density optrodes for multi-scale electrophysiology and optogenetic stimulation
Chamanzar, M., Borysov, M., Maharbiz, M. M., & Blanche, T. J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945199 · Cited by 9
The Electrode – Materials and Configurations
Merrill, D. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381409-8.00006-1 · Cited by 9
Reusable High Aspect Ratio 3-D Nickel Shadow Mask
Shandhi, M. M. H., Leber, M., Hogan, A. L., Warren, D. J., Bhandari, R., & Negi, S. (2017) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2017.2654126 · Cited by 9
Electroactive Polymeric Biomaterials
Povlich, L. K., Feldman, K. E., Shim, B. S., & Martin, D. C. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00042-8 · Cited by 9
Design and fabrication of differently shaped pyramids on Si{100} by anisotropic wet etching
Imaeda, K., Bessho, K., & Shikida, M. (2015) · Microsystem Technologies · doi:10.1007/s00542-015-2590-8 · Cited by 9
Fabrication of pen-shaped microneedle structure by using non-photolithographic pattern transfer
Shikida, M., Ando, M., Ishihara, Y., Yamaura, N., Ando, T., Sato, K., & Asaumi, K. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1217104 · Cited by 9
Silicon micro-needles with flexible interconnections
Holman, G., Hanein, Y., Wyeth, R. C., Willows, A. O. D., Denton, D. D., & Böhringer, K. F. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002325 · Cited by 9
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A., Morizio, J., Chapin, J. K., Nicolelis, M. A. L., & Wolf, P. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.pt2 · Cited by 9
Ballard, J. D., Dulgar-Tulloch, A., & Siegel, R. W. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs0815 · Cited by 9
Blagojevic, A., Seche, W., Choi, H., Davis, S. L., Elyahoodayan, S., Caputo, G. A., Lowe, T. C., Tavousi, P., Shahbazmohamadi, S., & Amini, S. (2024) · Advanced Materials Interfaces · doi:10.1002/admi.202400017 · Cited by 8
A Comprehensive Research Dissemination Model for Polymer-Based Neural Interfaces
Scholten, K., Xu, H., Lu, Z., Jiang, W., Jin, Z., Ortigoza-Diaz, J., Petrossians, A., Orler, S., Gallonio, R., Liu, X., et al. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3596222 · Cited by 8
Metadata
- Authors
- Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 8
- Pages
- 758-768
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111937020
- Cited by
- 881
- References
- 24
- Citations by year
- 2026: 21 · 2025: 29 · 2024: 41 · 2023: 24 · 2022: 35 · 2021: 32 · 2020: 40 · 2019: 39 · 2018: 34 · 2017: 41 · 2016: 36 · 2015: 41 · 2014: 43 · 2013: 56 · 2012: 41
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- neural interfaces, thermomigration, p+ silicon, micromachining, platinum coating, polyimide encapsulation, monocrystalline silicon substrate, galvanic isolation
- MeSH terms
- Animals, Biocompatible Materials, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Materials Testing, Microscopy, Electron, Scanning, Silicon, Somatosensory Cortex, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review