CoChat

A micromachined silicon depth probe for multichannel neural recording

Tae Hwan Yoon, Eun Jung Hwang, Dong Yong Shin, Se Ik Park, Seung Jae Oh, Sung Cherl Jung, Hyung Cheul Shin, Sung June Kim · 2000 · IEEE Transactions on Biomedical Engineering
Cited by 110

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A process of making a new type of silicon depth-probe microelectrode array is described using a combination of plasma and wet etch. The plasma etch, which is done using a low temperature oxide (LTO) mask, enables probe thickness to be controlled over a range from 5 to 90 mu. Bending tests show that the probe's mechanical strength depends largely on shank thickness. More force can be applied to thicker shanks while thinner shanks are more flexible. One can then choose a thickness and corresponding mechanical strength using the process developed. The entire probe shaping process is performed only at low temperature, and thus is consistent with the standard CMOS fabrication. Using the probe in recording from rat's somatosensory cortex, we obtained four channel simultaneous recordings which showed clear independence among channels with a signal-to-noise ratio performance comparable with that obtained using other devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.855936

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 12

  1. kewley, 1997, plasma-etched neural probes, Sensor Actuators A, 58, 27, 10.1016/S0924-4247(97)80221-X · DOI
  2. flinn, 1981, Engineering Materials and Their Applications, 534p
  3. 10.1016/0168-0102(94)90083-3 · DOI
  4. 10.1109/10.7273 · DOI · Paper page
  5. 10.1016/0956-5663(95)96802-6 · DOI
  6. 10.1016/0250-6874(84)87009-2 · DOI
  7. 10.1109/10.335862 · DOI · Paper page
  8. 10.1109/T-ED.1985.22102 · DOI · Paper page
  9. 10.1109/10.102802 · DOI
  10. 10.1109/84.506199 · DOI
  11. 10.1109/10.32101 · DOI · Paper page
  12. 10.1007/BFb0033868 · DOI

Cited by

See all 110

Metadata

Authors
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
2000-08
Volume
47
Issue
8
Pages
1082-1087
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2143703270
Cited by
110
References
3
FWCI
1.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A micromachined silicon depth probe for multichannel neural recording. https://app.cochat.ai/papers/10.1109/10.855936
The paper
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J. (2000). A micromachined silicon depth probe for multichannel neural recording. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.855936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.