The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Passive mixing in a three-dimensional serpentine microchannel
Abstract
A three-dimensional serpentine microchannel design with a "C shaped" repeating unit is presented in this paper as a means of implementing chaotic advection to passively enhance fluid mixing. The device is fabricated in a silicon wafer using a double-sided KOH wet-etching technique to realize a three-dimensional channel geometry. Experiments using phenolphthalein and sodium hydroxide solutions demonstrate the ability of flow in this channel to mix faster and more uniformly than either pure molecular diffusion or flow in a "square-wave" channel for Reynolds numbers from 6 to 70. The mixing capability of the channel increases with increasing Reynolds number. At least 98% of the maximum intensity of reacted phenolphthalein is observed in the channel after five mixing segments for Reynolds numbers greater than 25. At a Reynolds number of 70, the serpentine channel produces 16 times more reacted phenolphthalein than a straight channel and 1.6 times more than the square-wave channel. Mixing rates in the serpentine channel at the higher Reynolds numbers are consistent with the occurrence of chaotic advection. Visualization of the interface formed in the channel between streams of water and ethyl alcohol indicates that the mixing is due to both diffusion and fluid stirring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Self-citationStructure in turbulent mixing layers and wakes using a chemical reaction
Breidenthal, R. (1981) · Journal of Fluid Mechanics · doi:10.1017/s0022112081000906 · Cited by 375
Chaotic advection by laminar flow in a twisted pipe
Jones, S. W., Thomas, O. M., & Aref, H. (1989) · Journal of Fluid Mechanics · doi:10.1017/s0022112089003137 · Cited by 290
Self-citationCompensation structures for convex corner micromachining in silicon
Puers, R., & Sansen, W. (1990) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(90)87085-w · Cited by 178
Micro mixer with fast diffusion
Miyake, R., Lammerink, T. S. J., Elwenspoek, M., et al. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1993.296914 · Cited by 141
The effects of chaotic advection on heat transfer
Mokrani, A., Castelain, C., & Peerhossaini, H. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(96)00361-4 · Cited by 132
Heat transfer enhancement in coiled tubes by chaotic mixing
Acharya, N., Sen, M., & Hsueh-Chia, C. (1992) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(92)90090-f · Cited by 127
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Self-citationMicrofluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825780 · Cited by 1,098
Self-citationA Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Chaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly
Therriault, D., White, S. R., & Lewis, J. A. (2003) · Nature Materials · doi:10.1038/nmat863 · Cited by 707
Wang, S., Liu, K., Liu, J., Yu, Z. T. ‐., Xu, X., Zhao, L., Lee, T., Lee, E. K., Reiss, J., Lee, Y., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005853 · Cited by 620
Flexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595
Microfluidics: Basic issues, applications, and challenges
Stone, H. A., & Kim, S. (2001) · AIChE Journal · doi:10.1002/aic.690470602 · Cited by 552
Transport and reaction in microscale segmented gas–liquid flow
Günther, A., Khan, S. A., Thalmann, M., Trachsel, F., & Jensen, K. F. (2004) · Lab Chip · doi:10.1039/b403982c · Cited by 534
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Cai, G., Xue, L., Zhang, H., & Lin, J. (2017) · Micromachines · doi:10.3390/mi8090274 · Cited by 467
Liquid metal enabled microfluidics
Khoshmanesh, K., Tang, S.-Y., Zhu, J. Y., Schaefer, S., Mitchell, A., Kalantar-zadeh, K., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00046d · Cited by 458
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
A magnetic microstirrer and array for microfluidic mixing
Lu, L.-H., Ryu, K. S., & Liu, C. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.802899 · Cited by 446
Introduction: mixing in microfluidics
Ottino, J. M., & Wiggins, S. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1355 · Cited by 436
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
A novel in-plane passive microfluidic mixer with modified Tesla structures
Hong, C.-C., Choi, J.-W., & Ahn, C. H. (2004) · Lab on a Chip · doi:10.1039/b305892a · Cited by 429
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
A minute magneto hydro dynamic (MHD) mixer
Bau, H. H., Zhong, J., & Yi, M. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00851-6 · Cited by 371
Enhancement of microfluidic mixing using time pulsing
Glasgow, I., & Aubry, N. (2003) · Lab Chip · doi:10.1039/b302569a · Cited by 370
Wiggins, S., & Ottino, J. M. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1356 · Cited by 362
Helical flows and chaotic mixing in curved micro channels
Jiang, F., Drese, K. S., Hardt, S., Küpper, M., & Schönfeld, F. (2004) · AIChE Journal · doi:10.1002/aic.10188 · Cited by 350
A Review on Mixing in Microfluidics
Suh, Y. K., & Kang, S. (2010) · Micromachines · doi:10.3390/mi1030082 · Cited by 336
Paik, P., Pamula, V. K., Pollack, M. G., & Fair, R. B. (2003) · Lab on a Chip · doi:10.1039/b210825a · Cited by 327
Fluid mixing in a T-shaped micro-mixer
Bothe, D., Stemich, C., & Warnecke, H.-J. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2005.10.060 · Cited by 325
Sudarsan, A. P., & Ugaz, V. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507976103 · Cited by 324
Fluid mixing in planar spiral microchannels
Sudarsan, A. P., & Ugaz, V. M. (2006) · Lab Chip · doi:10.1039/b511524h · Cited by 320
Artificial cilia for active micro-fluidic mixing
Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., et al. (2008) · Lab on a Chip · doi:10.1039/b717681c · Cited by 296
A Review of Heating and Temperature Control in Microfluidic Systems: Techniques and Applications
Miralles, V., Huerre, A., Malloggi, F., & Jullien, M.-C. (2013) · Diagnostics · doi:10.3390/diagnostics3010033 · Cited by 284
Submillisecond organic synthesis: Outpacing Fries rearrangement through microfluidic rapid mixing
Kim, H., Min, K.-I., Inoue, K., Im, D. J., Kim, D.-P., & Yoshida, J.-I. (2016) · Science · doi:10.1126/science.aaf1389 · Cited by 271
Senn, S. M., & Poulikakos, D. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2003.12.025 · Cited by 268
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids
Neoh, K. H., Hassan, A. A., Chen, A., Sun, Y., Liu, P., Xu, K.-F., Wong, A. S. T., & Han, R. P. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.006 · Cited by 44
Metadata
- Authors
- Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-06
- Volume
- 9
- Issue
- 2
- Pages
- 190-197
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2108179405
- Cited by
- 1,197
- References
- 7
- FWCI
- 27.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.