Measurement of external pressures generated by nerve cuff electrodes
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
When external pressures are applied to a peripheral nerve, tissue damage can occur via compression and blood flow occlusion, resulting in degeneration and demyelination of axons. Although many types of nerve electrodes have been designed to avoid or minimize this pressure during stimulation of the nerve or recording of its activity, the measurement of the pressure exerted by these cuffs has not been reported. Currently, only theoretical models are used to predict nerve cuff electrode pressures. We have developed a nerve cuff electrode pressure sensor to measure external pressures exerted by peripheral nerve cuff electrodes. The sensor has a high sensitivity, linear response with little hysteresis and reproducible output. Pressure measurements have been obtained for split-ring and spiral cuff electrodes. The measurements obtained are in agreement with theoretical predictions. Moreover, they indicate that the pressures exerted by cuffs currently used for stimulation generate only a small amount of pressure, which is below the pressure required to occlude blood flow in nerves. The results also suggest that this new sensor can provide reliable measurement of external pressures exerted by nerve electrodes and would be an important tool for comparing various nerve cuff electrode designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 10×
“To date, only theoretical models [ 6 ] have been used to predict external pressures applied by NCE’s, and no experimental measurements of these pressures have been made.”
BackgroundMethodInfluentialLundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168 · cited 1×
“The double-wrap spiral cuff is modeled as two overlapping split rings [Fig.”
BackgroundStable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160 · cited 1×
“These cuff electrodes have also been used with great success to record neural activity in peripheral nerves [4], [23]–[25].”
BackgroundQuantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Spiral nerve cuff electrode for recordings of respiratory output
Sahin, M., Haxhiu, M. A., Durand, D. M., & Dreshaj, I. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.1.317 · Cited by 47
Self-citationLight and electron microscopic studies of phrenic nerves after long-term electrical stimulation
Kim, J. H., Manuelidis, E. E., Glenn, W. W. L., Fukuda, Y., Cole, D. S., & Hogan, J. F. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.58.1.0084 · Cited by 47
Kim (1976) · doi:10.1016/s0022-5223(19)40049-4 · Cited by 38
Cited by
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
“The natural coiling of these electrodes results in a spiral with an intimate fit between the nerve and the contacts, but allows expansion and contraction to reduce constriction of blood flow within the nerve [26].”
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
“The second is that selectively and simultaneously stimulating multiple subsets of axons using cuff electrodes could require cuffs with prohibitively large numbers of contacts (56–60), which increases the risk of the cuff electrode damaging the nerve (61).”
BackgroundInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
“It may be either sutured or installed without suturing [58].”
Background
Metadata
- Authors
- Cuoco, F. A., & Durand, D. M.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000-03
- Volume
- 8
- Issue
- 1
- Pages
- 35-41
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2109098808
- Cited by
- 36
- References
- 9
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of external pressures generated by nerve cuff electrodes. https://app.cochat.ai/papers/10.1109/86.830947
- The paper
- Cuoco, F. A., & Durand, D. M. (2000). Measurement of external pressures generated by nerve cuff electrodes. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.830947
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.