The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Open accessAbstract
Methods to overcome metal artifacts in computed tomography (CT) images have been researched and developed for nearly 40 years. When X-rays pass through a metal object, depending on its size and density, different physical effects will negatively affect the measurements, most notably beam hardening, scatter, noise, and the non-linear partial volume effect. These phenomena severely degrade image quality and hinder the diagnostic power and treatment outcomes in many clinical applications. In this paper, we first review the fundamental causes of metal artifacts, categorize metal object types, and present recent trends in the CT metal artifact reduction (MAR) literature. To improve image quality and recover information about underlying structures, many methods and correction algorithms have been proposed and tested. We comprehensively review and categorize these methods into six different classes of MAR: metal implant optimization, improvements to the data acquisition process, data correction based on physics models, modifications to the reconstruction algorithm (projection completion and iterative reconstruction), and image-based post-processing. The primary goals of this paper are to identify the strengths and limitations of individual MAR methods and overall classes, and establish a relationship between types of metal objects and the classes that most effectively overcome their artifacts. The main challenges for the field of MAR continue to be cases with large, dense metal implants, as well as cases with multiple metal objects in the field of view. Severe photon starvation is difficult to compensate for with only software corrections. Hence, the future of MAR seems to be headed toward a combined approach of improving the acquisition process with dual-energy CT, higher energy X-rays, or photon-counting detectors, along with advanced reconstruction approaches. Additional outlooks are addressed, including the need for a standardized evaluation system to compare MAR methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mastering the game of Go with deep neural networks and tree search
Silver, D., Huang, A., Maddison, C. J., Guez, A., Sifre, L., van den Driessche, G., Schrittwieser, J., Antonoglou, I., Panneershelvam, V., Lanctot, M., et al. (2016) · Nature · doi:10.1038/nature16961 · Cited by 15,612
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Computed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Reduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537
Lee, M.-J., Kim, S., Lee, S.-A., Song, H.-T., Huh, Y.-M., Kim, D.-H., Han, S. H., & Suh, J.-S. (2007) · RadioGraphics · doi:10.1148/rg.273065087 · Cited by 513
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
Self-citationIterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Self-citationKachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Self-citationEvaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303
X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses
Zhao, S., Robeltson, D. D., Wang, G., Whiting, B., & Bae, K. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897816 · Cited by 244
Self-citationMetal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Bal, M., & Spies, L. (2006) · Medical Physics · doi:10.1118/1.2218062 · Cited by 234
Mahnken, A. H., Raupach, R., Wildberger, J. E., Jung, B., Heussen, N., Flohr, T. G., Günther, R. W., & Schaller, S. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000086495.96457.54 · Cited by 227
Pessis, E., Campagna, R., Sverzut, J.-M., Bach, F., Rodallec, M., Guerini, H., Feydy, A., & Drapé, J.-L. (2013) · RadioGraphics · doi:10.1148/rg.332125124 · Cited by 223
A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
Kalender, W. A., & Watzke, O. (2004) · European Radiology · doi:10.1007/s00330-004-2263-y · Cited by 209
Lemmens, C., Faul, D., & Nuyts, J. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.929103 · Cited by 194
Meinel, F. G., Bischoff, B., Zhang, Q., Bamberg, F., Reiser, M. F., & Johnson, T. R. C. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31824c86a3 · Cited by 169
Metal artifact reduction in x‐ray computed tomography (CT) by constrained optimization
Zhang, X., Wang, J., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3533711 · Cited by 165
Zhou, C., Zhao, Y. E., Luo, S., Shi, H., li, L., Zheng, L., Zhang, L. J., & Lu, G. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.05.009 · Cited by 161
Yazdi, M., Gingras, L., & Beaulieu, L. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.02.052 · Cited by 142
Lewis, M., Reid, K., & Toms, A. P. (2012) · Skeletal Radiology · doi:10.1007/s00256-012-1458-6 · Cited by 140
Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction
Wang, G., Vannier, M. W., & Cheng, P. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699000057 · Cited by 140
Self-citationPrell, D., Kyriakou, Y., Beister, M., & Kalender, W. A. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/21/009 · Cited by 130
Fast iterative algorithm for metal artifact reduction in X-ray CT
Wang, G., Frei, T., & Vannier, M. W. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80576-0 · Cited by 127
Self-citationCT of Metal Implants: Reduction of Artifacts Using an Extended CT Scale Technique
Link, T. M., Berning, W., Scherf, S., Joosten, U., Joist, A., Engelke, K., & Daldrup-Link, H. E. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200001000-00029 · Cited by 123
CT scans through metal scanning technique versus hardware composition
Haramati, N., Staron, R. B., Mazel-Sperling, K., Freeman, K. D., Nickoloff, E. L., Barax, C. N., & Feldman, F. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90080-9 · Cited by 105
Yu, L., Li, H., Mueller, J., Kofler, J. M., Liu, X., Primak, A. N., Fletcher, J. G., Guimarães, L., Macedo, T. A., & McCollough, C. H. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b0a2f9 · Cited by 95
A Segmentation-Based Method for Metal Artifact Reduction
Yu, H., Zeng, K., Bharkhada, D., et al. (2007) · Academic Radiology · doi:10.1016/j.acra.2006.12.015 · Cited by 90
A hybrid metal artifact reduction algorithm for x‐ray CT
Zhang, Y., Yan, H., Jia, X., Yang, J. Q., Jiang, S. B., & Mou, X. (2013) · Medical Physics · doi:10.1118/1.4794474 · Cited by 82
Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
Lell, M., Meyer, E., Kuefner, M. A., May, M. S., Raupach, R., Uder, M., & Kachelrieß, M. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e3182532f17 · Cited by 76
Model-Based Tomographic Reconstruction of Objects Containing Known Components
Stayman, J. W., Otake, Y., Prince, J. L., Khanna, A. J., & Siewerdsen, J. H. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2199763 · Cited by 75
Prell, D., Kyriakou, Y., Kachelrie�, M., & Kalender, W. A. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181e94384 · Cited by 70
Segmentation of artifacts and anatomy in CT metal artifact reduction
Karimi, S., Cosman, P. C., Wald, C., et al. (2012) · Medical Physics · doi:10.1118/1.4749931 · Cited by 58
Statistical Image Reconstruction for Inconsistent CT Projection Data
Oehler, M., & Buzug, T. M. (2007) · Methods of Information in Medicine · doi:10.1160/me9041 · Cited by 51
Joemai, R. M. S., Bruin, P. W. D., Veldkamp, W. J. H., & Geleijns, J. (2012) · Medical Physics · doi:10.1118/1.3679863 · Cited by 50
Segmentation‐free empirical beam hardening correction for CT
Schüller, S., Sawall, S., Stannigel, K., et al. (2015) · Medical Physics · doi:10.1118/1.4903281 · Cited by 40
Metal artifact correction for x‐ray computed tomography using kV and selective MV imaging
Wu, M., Keil, A., Constantin, D. E., et al. (2014) · Medical Physics · doi:10.1118/1.4901551 · Cited by 39
Prior‐based artifact correction (PBAC) in computed tomography
Heußer, T., Brehm, M., Ritschl, L., Sawall, S., & Kachelrieß, M. (2014) · Medical Physics · doi:10.1118/1.4851536 · Cited by 36
Streak Preventive Image Reconstruction with ART and Adaptive Filtering
Rangayyan, R. M., & Gordon, R. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307569 · Cited by 34
A post-processing algorithm to reduce metallic clip artifacts in CT images
Tuy, H. K. (1993) · European Radiology · doi:10.1007/bf00169785 · Cited by 34
Snyder, D. L., O’Sullivan, J. A., Whiting, B. R., Murphy, R. J., Benac, J., Cataldo, J. A., Politte, D. G., & Williamson, J. F. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959298 · Cited by 33
CT artifact correction: an image-processing approach
Soltanian‐Zadeh, H., Windham, J. P., & Soltanianzadeh, J. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.237950 · Cited by 28
An opposite view data replacement approach for reducing artifacts due to metallic dental objects
Yazdi, M., Lari, M. A., Bernier, G., & Beaulieu, L. (2011) · Medical Physics · doi:10.1118/1.3566016 · Cited by 28
A fully 3D approach for metal artifact reduction in computed tomography
Kratz, B., Weyers, I., & Buzug, T. M. (2012) · Medical Physics · doi:10.1118/1.4762289 · Cited by 28
A simple computational method for reducing streak artifacts in CT images
Henrich, G. (1980) · Computerized Tomography · doi:10.1016/0363-8235(80)90043-5 · Cited by 24
Metal artifact reduction for CT-based luggage screening
Karimi, S., Martz, H. E., & Cosman, P. C. (2015) · Journal of X-Ray Science and Technology · doi:10.3233/xst-150499 · Cited by 18
Complementary contrast media for metal artifact reduction in dual-energy CT
Lambert, J. W., Edic, P. M., Fitzgerald, P. B., Torres, A. S., & Yeh, B. M. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082177 · Cited by 3
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Metadata
- Authors
- Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G.
- Venue
- IEEE Access
- Published
- 2016
- Volume
- 4
- Pages
- 5826-5849
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2520526731
- Cited by
- 290
- References
- 51
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.