CoChat

Economic Impacts and Mitigation for the Grid Connected Electric Vehicle Charging: A Technical and Operational Overview

Open access

The DOI matches its Crossref record; 35 of the 171 references it cites were found in a registry or an index, and 125 are not checked yet; 34 of the 151 sources its claims cite were checked for support.

Abstract

The rapid growth of residential electric vehicle (EV) adoption is reshaping distribution networks, shifting load patterns from relatively dispersed background demand to synchronized, high-amplitude charging events. When charging is unmanaged, these concentrated loads can exceed thermal and voltage limits, accelerate transformer aging, intensify harmonic stress, and prompt costly infrastructure upgrades. Unlike prior reviews that examine technical, economic, and coordination aspects separately, this paper brings them together within an integrated technical–economic analytical review that considers thermal limits, voltage security, and battery state-of-charge constraints simultaneously. Transformer loss-of-life, harmonic–thermal interactions, peak amplification, and renewable–EV timing mismatch are quantitatively analyzed alongside infrastructure deferral benefits and ancillary-service revenues. Economic performance is evaluated by balancing upgrade deferral, V2G revenue, battery degradation costs, and coordination overhead. A comparative assessment of ARIMA, LSTM, and reinforcement learning methods highlights practical trade-offs between forecasting accuracy and computational scalability under evolving charging behavior. Evidence from field pilots reports 10–30% peak reduction, 20–65% charging cost savings, and $100–$500 per EV-year gross V2G revenue, depending on market structure and incentives. Overall, this review provides an integrated analytical foundation to support resilient and economically efficient EV–grid integration under high-penetration conditions.

Verified 2026-11-22 · 125 references not checked yet

Overview

CoChat Summary

TL;DR

This review synthesizes technical, operational, economic, and policy literature on grid-connected EV charging, focusing on distribution-system impacts and mitigation. It argues that uncoordinated charging can worsen peak demand, voltage imbalance, transformer aging, harmonics, and feeder stress, while managed charging, V2G, DER/storage, grid automation, and supportive policy can mitigate these effects.

Key findings

  • Unmanaged EV charging can increase peak demand by 30%, while controlled charging approaches can achieve peak load reductions of up to 40%; V2G may address some 15–20% of renewable energy intermittency.
  • Transformer thermal stress is severe: every 10°C increase in operating temperature reduces insulation lifetime by 50%, and real-time transformer monitoring is discussed for neighborhoods with EV penetration greater than 30%.
  • Charging levels differ substantially: L1 operates at 120 V/1.3–2.4 kW, L2 at 240 V/3.3–19.2 kW, and DCFC up to 350 kW; DCFC creates abrupt grid pressure, voltage dips, and faster transformer aging.
  • V2G can provide ancillary services, with one million EVs at 10 kW V2G estimated to provide up to 10 GW of regulation capacity; smart charging, ToU/DR, ML forecasting, and grid automation are mitigation pathways, with self-healing cited to reduce outage durations in medium-voltage distribution networks during peak charging hours by more than 60%.

Methods

  • Design: a comprehensive multidisciplinary review and critical assessment of EV charging impacts on power distribution systems, with emphasis on community-level effects.
  • Data/sample: draws on existing literature, simulation models, and real-world installations; no primary experimental dataset or systematic search protocol is described.
  • Analysis: thematic synthesis across technical impacts (peak load, voltage, transformers, harmonics, feeders), charging technologies, smart charging/grid control, community/geographic challenges, grid modernization, and policy/economic/cybersecurity dimensions.

Limitations

  • The paper states that many reviewed studies rely on historical data, favorable assumptions, high user participation, or lack real-world validation; examples include managed charging models not validated against real-world data, DR studies assuming high participation, and V2G limited by battery degradation and lack of long-term field data.
  • Evident from the text: as a narrative review, it does not report a systematic search strategy, inclusion/exclusion criteria, or quality appraisal; several quantitative claims are attributed to cited figures/studies without full methodological detail.
  • Evident: coverage is broad but some sections rely on illustrative figures and projections (e.g., IEA/BloombergNEF EV forecasts) that may not capture policy reversals, supply-chain disruptions, or local behavioral variation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/access.2026.3684508

Cites

35 of 171 references verified0 citation errors · 11 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

8 Valid · 30 Not valid · 100 Not checked · 60 Own results and interpretations

87 more claims · 20 with their cited sources checked

Create a free account to see all 198 claims and to verify the 22 references still open.

See all claims — free account
  • It may state two separate claims as one. 73
  • Probably not a substantial claim. 50
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 171 references

Research works printed but not linked: 3

  1. [19] G. C. Christoforidis, P. I. Lazaridis, P. Stathopoulos, and A. Sideris, "Effect of loads and other key factors on oil-transformer aging," Energies, vol. 8, no. 10, pp. 12147–12163, 2015.
  2. [60] International Energy Agency, "Canada 2022 Energy Policy Review," OECD, 2022.
  3. 10.1016/j.est.2026.120546 · DOI

Cited by

Metadata

Authors
Ikhajangbe, O. E., Dhulipati, H., & Liu, S.
Affiliations
Carleton University (CA)
Venue
IEEE Access
Published
2026
Volume
14
Pages
60099-60121
ISSN
2169-3536 (ISSN-L)
OpenAlex
W7154592946
Cited by
5
References
157
Citations by year
2026: 5
FWCI
7.92
Type
journal article
Language
en
Open access
Locations
  • IEEE Access (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Carleton University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Vehicles and Infrastructure
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
Keywords
electric vehicle charging, distribution networks, EV charging coordination, battery state of charge constraints, battery degradation cost, reinforcement learning, LSTM, ARIMA, EV grid integration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.