Abstract

Permanent magnet synchronous machines (PMSM) have been widely used in various applications due to their characteristics of high power density, high efficiency, and high torque to current ratio. However, PMSMs are not immune to electrical faults, which requires an efficient and reliable condition monitoring method to avoid downtime or even catastrophic failures. This paper introduces a novel diagnostic method for PMSM stator winding short-circuit faults, which are of the most common type of faults that could occur in PMSMs. The implementation of this new diagnostic method is based on pattern identification of the loci of the machine's current space vectors. This method is computationally efficient and does not require voltage or position sensors. Experimental verification shows that such a method can detect the short-circuit fault at an incipient stage better than other existing diagnostic methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ecce.2014.6953825

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 20

  1. 10.1109/TIE.2010.2064276 · DOI · Paper page
  2. 10.1109/TIE.2007.909060 · DOI · Paper page
  3. 10.1109/TIA.2009.2013557 · doi:10.1109/tia.2009.2013557
  4. 10.1109/41.873216 · DOI · Paper page
  5. 10.1109/TIA.2004.834012 · DOI · Paper page
  6. 10.1109/60.911400 · DOI · Paper page
  7. 10.1109/TIA.2013.2253081 · DOI · Paper page
  8. 10.1109/TIE.2010.2060463 · DOI · Paper page
  9. 10.1109/TIE.2008.2007529 · DOI · Paper page
  10. 0, Motor stator Insulation Monitor, GE Measurement & Control
  11. 10.1109/TEC.1986.4765668 · DOI · Paper page
  12. 10.1109/TIA.2006.870038 · DOI
  13. 10.1109/2943.930988 · DOI · Paper page
  14. 10.1109/TPEL.2012.2198077 · DOI · Paper page
  15. 10.1109/TVT.2007.896978 · DOI · Paper page
  16. 10.1109/TEC.2005.847976 · DOI · Paper page
  17. 10.1109/TIE.2008.2004662 · DOI · Paper page
  18. yeh, 2004, Diagnosis of stator winding inter-turn shorts in induction motors fed by PWM-inverter drive systems using a timing-series data mining techniques, Proc IEEE ICPST, 891
  19. 10.1109/TIA.2003.811784 · DOI · Paper page
  20. he, 2013, Diagnosis of stator short-circuit faults in an IPM synchronous machine using a space vector pendulous oscillation method, Proc IEEE Int Electric Machines Drives Conf (IEMDC), 727

Cited by

Metadata

Authors
He, J., Somogyi, C., Strandt, A., & Demerdash, N. A. O.
Venue
2014 IEEE Energy Conversion Congress and Exposition (ECCE)
Publisher
IEEE
Published
2014-09
Pages
3125-3130
OpenAlex
W2322096651
Cited by
39
References
2
FWCI
1.39
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.