Investigation of fault modes of voltage-fed inverter system for induction motor drive
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The authors describe a systematic investigation into the various fault modes of a voltage-fed pulse-width-modulated (PWM) inverter system for induction motor drives. All the fault modes were identified, and a preliminary mathematical analysis was made for the key fault types-namely, input supply single line to ground fault, rectifier diode short circuit, inverter transistor base drive open, and inverter transistor short circuit conditions. The predicted fault performances were substantiated by a simulation study. The study was used to determine stresses in power circuit components and to evaluate satisfactory postfault steady-state operating regions. The results are equally useful for better protection system design and easy fault diagnosis.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved Reliability in Solid-State AC Drives by Means of Multiple Independent Phase Drive Units
Jahns, T. M. (1980) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1980.4503793 · Cited by 358
Remedial strategies for brushless DC drive failures
Speed, R., & Wallace, A. K. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.54251 · Cited by 131
The simulation of brushless DC drive failures
Wallace, A. K., & Spée, R. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1988.18134 · Cited by 27
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“fault diagnosis of electric machines and drives [1] have been performed, with some specifically focused on fault diagnosis of semiconductor devices and inverters [2]–[4].”
BackgroundExperimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Baran, M. E., & Mahajan, N. R. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.877086 · Cited by 380
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Fault Diagnostic System for a Multilevel Inverter Using a Neural Network
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897128 · Cited by 291
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284
“The various fault modes of a VSI system for an induction motor are investigated in [ 3 ].”
BackgroundFault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
“Moreover, the current dc component generates unequal current stress in the upper and lower transistors in the inverter, which may cause thermal defects in the transistors [1].”
BackgroundInfluentialJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Campos-Delgado, D. U., & Espinoza-Trejo, D. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2047829 · Cited by 224
“In [14], the types of faults that can be developed in a voltage-fed inverter have been studied, the fault types have been mathematically analyzed, and the predicted fault performances have been verified by simulation.”
MethodClosed-loop control impact on the diagnosis of induction motors faults
Bellini, A., Filippetti, F., Franceschini, G., & Tassoni, C. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.871280 · Cited by 199
Benbouzid, M. E. H., Diallo, D., & Zeraoulia, M. (2007) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2006.889579 · Cited by 198
A Fault-Tolerant Control Architecture for Induction Motor Drives in Automotive Applications
Diallo, D., Benbouzid, M. E. H., & Makouf, A. (2004) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2004.833610 · Cited by 194
“SEVERAL failures can affect electrical motor drives [1]–[4] and many different remedial techniques have been proposed [5]–[10].”
BackgroundRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Model-based fault diagnosis in electric drives using machine learning
Murphey, Y. L., Masrur, M. A., Chen, Z., & Zhang, B. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.875568 · Cited by 165
“In [24], Kastha and Bose systematically described the effect of different types of fault in a voltage-fed PWM inverter induction motor drive that uses the open-loop volts/hertz speed control method.”
Analysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
“The short-switch failure and the open-switch failure are the most common types of failure modes that compromise reliable operation of motor drive systems [19], [20].”
BackgroundBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
“Open circuit faults are caused by excessive heating of components, effect of overwhelmed forces and short circuit faults are caused by overloads and high temperature[48].”
BackgroundMethodInfluentialD-Q current signature based single winding open fault detection for SM-PMAC machine drives
Kuruppu, S. S., & Kulatunga, N. A. (2013) · 2013 International Electric Machines & Drives Conference · doi:10.1109/iemdc.2013.6556310 · Cited by 5
Metadata
- Authors
- Kastha, D., & Bose, B. K.
- Venue
- Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting
- Publisher
- IEEE
- Published
- 2003-01-02
- Pages
- 858-866
- OpenAlex
- W2162087833
- Cited by
- 370
- References
- 3
- FWCI
- 23.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.