The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Abstract
This paper presents the design and implementation of an analog signal processor (ASP) ASIC for portable ECG monitoring systems. The ASP ASIC performs four major functionalities: 1) ECG signal extraction with high resolution, 2) ECG signal feature extraction, 3) adaptive sampling ADC for the compression of ECG signals, 4) continuous-time electrode-tissue impedance monitoring for signal integrity monitoring. These functionalities enable the development of wireless ECG monitoring systems that have significantly lower power consumption yet that are more capable than their predecessors. The ASP has been implemented in 0.5 μm CMOS process and consumes 30 μW from a 2 V supply. The noise density of the ECG readout channel is 85 nV/√Hz and the CMRR is better that 105 dB. The adaptive sampling ADC is capable of compressing the ECG data by a factor of 7 and the heterodyne chopper readout extracts the features of the ECG signals. Combination of these two features leads to a factor 4 reduction in the power consumption of a wireless ECG monitoring system. Furthermore, the proposed continuous-time impedance monitoring circuit enables the monitoring of the signal integrity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“A popular approach for removing the motion artifact signals from the biopotential recordings is adaptive filtering [29], which requires the presence of a reference signal that is correlated with the motion artifact signals but uncorrelated with biopotential signals.”
BackgroundMedical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Estimation of QRS Complex Power Spectra for Design of a QRS Filter
Thakor, N. V., Webster, J. G., & Tompkins, W. J. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325393 · Cited by 427
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414 · cited 1×
“10 [15] and the gain programmability is integrated using the flip-over architecture as presented in [22].”
MethodA 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Self-citationA 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
Self-citationEnz, C. C., Vittoz, E. A., & Krummenacher, F. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052730 · Cited by 241
Minimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 142
Comparison of methods for adaptive removal of motion artifact
Hamilton, P. S., Curley, M., Aimi, R., & Sae-Hau, C. (2002) · Computers in cardiology · doi:10.1109/cic.2000.898537 · Cited by 93
Human++: From technology to emerging health monitoring concepts
Penders, J., Gyselinckx, B., Vullers, R. J. M., Nil, M. D., Nimmala, V. S. R., van de Molengraft, J., Yazicioglu, F., Torfs, T., Leonov, V. N., Merken, P. J., et al. (2008) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2008.4575026 · Cited by 70
Self-citationSensium: an ultra-low-power wireless body sensor network platform: Design & application challenges
Wong, A., McDonagh, D., Omeni, O., Nunn, C., Hernandez-Silveira, M., & Burdett, A. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334001 · Cited by 58
Gibbs, P., Wood, L. B., & Asada, H. H. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.600781 · Cited by 42
Continuous-Time Digital Signal Processors
Li, Y. W., Shepard, K. L., & Tsividis, Y. (2005) · IEEE International Symposium on Asynchronous Circuits and Systems (ASYNC) · doi:10.1109/async.2005.15 · Cited by 37
Ottenbacher, J., Kirst, M., Jatobá, L., Grossmann, U., & Stork, W. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_102 · Cited by 24
Cited by
Compressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311
Van Helleputte, N., Konijnenburg, M., Pettine, J., Jee, D.-W., Kim, H., Morgado, A., Van Wegberg, R., Torfs, T., Mohan, R., Breeschoten, A., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2359962 · Cited by 253
Self-citationNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“Adaptive sampling [82,83] is an activity-based technique that allows a significant decrease in the data rate by an order of magnitude.”
BackgroundA 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
Metadata
- Authors
- Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2011-01
- Volume
- 46
- Issue
- 1
- Pages
- 209-223
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2054295738
- Cited by
- 263
- References
- 19
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.