A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper presents a noninvasive wireless sensor platform for continuous health monitoring. The sensor system integrates a loop antenna, wireless sensor interface chip, and glucose sensor on a polymer substrate. The IC consists of power management, readout circuitry, wireless communication interface, LED driver, and energy storage capacitors in a 0.36-mm2CMOS chip with no external components. The sensitivity of our glucose sensor is 0.18 μA·mm-2·mM-1. The system is wirelessly powered and achieves a measured glucose range of 0.05-1 mM with a sensitivity of 400 Hz/mM while consuming 3 μW from a regulated 1.2-V supply.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While many remain battery-powered, wireless power transfer techniques can further reduce the form factor and invasiveness of these devices4–10.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [9]
In the citing paper
“Further advances for the field came with the demonstration of electrochemical biosensing by the Parviz team114-116. This group investigated different biosensing strategies to achieve good sensitivity, linearity and accuracy.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“Further progress has since been made by embedding a wireless read out chip (2.4 GHz) and by powering with far-field electromagnetic radiation (3μW within 15 cm)116.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
In the citing paper
“(iii) the brittle and rigid materials of the integrated electronic system, such as surface-mounted IC chips and rigid interconnects, which could damage the cornea or the eyelid (20–22);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
Citations
Cites
Global estimates of the prevalence of diabetes for 2010 and 2030
Shaw, J. E., Sicree, R. A., & Zimmet, P. Z. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.007 · Cited by 7,216
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Self-citationBerman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 475
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.2005927 · Cited by 179
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
A 9 $\mu$A, Addressable Gen2 Sensor Tag for Biosignal Acquisition
Yeager, D. J., Zhang, F., Zarrasvand, A., George, N. T., Daniel, T., & Otis, B. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2063930 · Cited by 106
Self-citationA fully integrated RF-powered contact lens with a single element display
Pandey, J., Liao, Y.-T., Lingley, A., Mirjalili, R., Parviz, B., & Otis, B. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081989 · Cited by 96 · cited 1×
“Contact-lens functionality could be greatly expanded by creating heterogeneous systems with embedded electronics and wireless telemetry.”
BackgroundSelf-citationA soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216947 · Cited by 81
Research works printed but not linked: 1
- 2006, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
Cited by
Items 101–200 of 376
A survey of wearable energy harvesting systems
Khan, A. S., & Khan, F. U. (2021) · International Journal of Energy Research · doi:10.1002/er.7394 · Cited by 56
Kobayashi, A., Ikeda, K., Ogawa, Y., Kai, H., Nishizawa, M., Nakazato, K., & Niitsu, K. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2735447 · Cited by 52
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Polymers and Plastics Modified Electrodes for Biosensors: A Review
Lanzalaco, S., & Molina, B. G. (2020) · Molecules · doi:10.3390/molecules25102446 · Cited by 51
A Thermally Powered ISFET Array for On-Body pH Measurement
Douthwaite, M., Koutsos, E., Yates, D. C., Mitcheson, P. D., & Georgiou, P. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2727219 · Cited by 51
Jeon, C., Koo, J., Lee, K., Lee, M., Kim, S., Shin, S., Hahn, S. K., & Sim, J. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2959493 · Cited by 49
Monitoring of physiological sounds with wearable device based on piezoelectric MEMS acoustic sensor
Qu, M., Chen, X., Yang, D., Li, D., Zhu, K., Guo, X., & Xie, J. (2021) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ac371e · Cited by 48
Khan, N. U., Khan, F. U., Farina, M., & Merla, A. (2024) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-024-01382-4 · Cited by 47
Smart Wearable Sensor Fuels Noninvasive Body Fluid Analysis
Wang, K., Liu, W., Wu, J., Li, H., Peng, H., Zhang, J., Ding, K., Wang, X., Hou, C., Zhang, H., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c22054 · Cited by 52
Power supply for electronic contact lenses: Abiotic glucose fuel cells vs. Mg/air batteries
Frei, M., Martin, J., Kindler, S., Cristiano, G., Zengerle, R., & Kerzenmacher, S. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.08.101 · Cited by 47
Wearable biosensors for human fatigue diagnosis: A review
Zhang, J., Chen, M., Peng, Y., Li, S., Han, D., Ren, S., Qin, K., Li, S., Han, T., Wang, Y., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10318 · Cited by 49
An Integrated Control and Readout Circuit for Implantable Multi-Target Electrochemical Biosensing
Ghoreishizadeh, S. S., Baj-Rossi, C., Cavallini, A., Carrara, S., & Micheli, G. D. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2315157 · Cited by 44
CMOS image sensor-based implantable glucose sensor using glucose-responsive fluorescent hydrogel
Tokuda, T., Takahashi, M., Uejima, K., Masuda, K., Kawamura, T., Ohta, Y., Motoyama, M., Noda, T., Sasagawa, K., Okitsu, T., et al. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003859 · Cited by 44
Hayashi, K., Arata, S., Murakami, S., Nishio, Y., Kobayashi, A., & Niitsu, K. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2860636 · Cited by 44
Chen, Y., Lu, S.-Y., & Liao, Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936373 · Cited by 44
Self-citationGinnaram, S., Qiu, J.-T. T., & Maikap, S. (2020) · ACS Omega · doi:10.1021/acsomega.0c00795 · Cited by 45
A portable optical human sweat sensor
Al-omari, M., Liu, G., Mueller, A., Mock, A., Ghosh, R. N., Smith, K., & Kaya, T. (2014) · Journal of Applied Physics · doi:10.1063/1.4901332 · Cited by 43
Choi, H., Nylon, J., Luzio, S. D., Beutler, J., & Porch, A. (2014) · IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications · doi:10.1109/imws-bio.2014.7032398 · Cited by 43
Kang, J., Rao, S., Chiang, P. Y., & Natarajan, A. S. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2536663 · Cited by 43
Chien, J., Baker, S. W., Soh, H. T., & Arbabian, A. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3020789 · Cited by 43
Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System
Chiou, J., Hsu, S., Liao, Y., Huang, Y., Yeh, G., Kuei, C.-K., & Dai, K.-S. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2594058 · Cited by 42
Self-citationWireless Communication and Power Harvesting in Wearable Contact Lens Sensors
Yuan, M., Das, R., McGlynn, E., Ghannam, R., Abbasi, Q. H., & Heidari, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3055077 · Cited by 47
A Low-Power 1-V Potentiostat for Glucose Sensors
Zuo, L., ISLAM, S. K., Mahbub, I., & Quaiyum, F. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2387691 · Cited by 41
Rf-powered systems using steep-slope devices
Li, X., Heo, U. D., Ma, K., Narayanan, V., Liu, H., & Datta, S. (2014) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2014.6933988 · Cited by 41
Chan, W. P., Narducci, M., Gao, Y., Cheng, M.-Y., Cheong, J. H., George, A. K., Cheam, D. D., Leong, S. C., Damalerio, R., Lim, R., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2345754 · Cited by 39
Insight into continuous glucose monitoring: from medical basics to commercialized devices
Chmayssem, A., Nadolska, M., Tubbs, E., Sadowska, K., Vadgma, P., Shitanda, I., Tsujimura, S., Lattach, Y., Peacock, M., Tingry, S., et al. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05743-w · Cited by 40
50nW Opamp-Less ΔΣ-Modulated Bioimpedance Spectrum Analyzer for Electrochemical Brain Interfacing
ElAnsary, M., Soltani, N., Kassiri, H., Machado, R., Dufour, S., Carlen, P. L., Thompson, M. E., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2981033 · Cited by 38
Development of a new scleral contact lens with encapsulated photodetectors for eye tracking
Massin, L., Nourrit, V., Lahuec, C., Seguin, F., Adam, L., Daniel, E., & Tocnaye, J.-L. D. B. D. L. (2020) · Optics Express · doi:10.1364/oe.399823 · Cited by 38
A 25-µW All-MOS Potentiostatic Delta-Sigma ADC for Smart Electrochemical Sensors
Sutula, S., Pallarès, J., Gonzalo‐Ruiz, J., Muñoz, F. X., Terés, L., & Serra-Graells, F. (2014) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2013.2284179 · Cited by 38
State-of-the-Art in Smart Contact Lenses for Human–Machine Interaction
Xia, Y., Khamis, M., Fernández, F. A., Heidari, H., Butt, H., Ahmed, Z., Wilkinson, T. D., & Ghannam, R. (2022) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2022.3224683 · Cited by 41
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36
Graphene electrodes for adaptive liquid crystal contact lenses
Kaur, S., Kim, Y.-J., Milton, H. E., Mistry, D., Syed, I. M., Bailey, J., Novoselov, K. S., Jones, J. C., Morgan, P. B., Clamp, J., et al. (2016) · Optics Express · doi:10.1364/oe.24.008782 · Cited by 36
A Wirelessly Powered CMOS Electrochemical Sensing Interface With Power-Aware RF-DC Power Management
Tsai, J.-H., Kuo, C.-Y., Lin, S.-H., Lin, F.-T., & Liao, Y. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2797238 · Cited by 35
Self-citationAdvanced Nanoscale Build‐Up Sensors for Daily Life Monitoring of Diabetics
El‐Safty, S. A., & Shenashen, M. A. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202000153 · Cited by 36
Authenticating On-Body Backscatter by Exploiting Propagation Signatures
Luo, Z., Wang, W., Xiao, J., Huang, Q., Jiang, T., & Zhang, Q. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3266002 · Cited by 34
A Review of CMOS Electrochemical Readout Interface Designs for Biomedical Assays
Lu, S.-Y., Shan, S.-S., Lu, T.-H., Yeh, Y.-H., Kuo, S.-C., Chen, Y., & Liao, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3056443 · Cited by 37
Self-citationAn 11 $\mu{\rm W}$ Sub-pJ/bit Reconfigurable Transceiver for mm-Sized Wireless Implants
Yakovlev, A., Jang, J. H., & Pivonka, D. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2371031 · Cited by 38
3D Printing Assisted Wearable and Implantable Biosensors
Maji, S., Kwak, M., Kumar, R., & Lee, H. (2025) · Biosensors · doi:10.3390/bios15090619 · Cited by 33
Powering electronic contact lenses: current achievements, challenges, and perspectives
Blum, Z., Pankratov, D., & Shleev, S. (2014) · Expert Review of Ophthalmology · doi:10.1586/17469899.2014.922873 · Cited by 35
Polarization Reconfigurable Planar Inverted-F Antenna for Implantable Telemetry Applications
Yang, X., Wong, H., & Xiang, J. (2019) · IEEE Access · doi:10.1109/access.2019.2941388 · Cited by 32
Shin, S.-U., Choi, M., Jung, S., Lee, H., & Cho, G. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2947237 · Cited by 32
Technology platforms for remote monitoring of vital signs in the new era of telemedicine
Zhao, F., Li, M., & Tsien, J. Z. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1050957 · Cited by 35
Release of Fluconazole from Contact Lenses Using a Novel In Vitro Eye Model
Phan, C., Bajgrowicz, M., Gao, H., Subbaraman, L. N., & Jones, L. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000760 · Cited by 31
Photonic Nanomaterials for Wearable Health Solutions
Park, T., Leem, J. W., Kim, Y. L., & Lee, C. H. (2025) · Advanced Materials · doi:10.1002/adma.202418705 · Cited by 32
Aymerich, J., Márquez, A., Muñoz‐Berbel, X., del Campo, F. J., Guirado, G., Terés, L., Serra-Graells, F., & Dei, M. (2020) · IEEE Access · doi:10.1109/access.2020.2984177 · Cited by 30
Wearable and Battery-Free Health-Monitoring Devices With Optical Power Transfer
Nattakarn, W., Haruta, M., Sasagawa, K., Tokuda, T., Carrara, S., & Ohta, J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3050139 · Cited by 31
Electrochemical Sensing in Contact Lenses
Liu, H., Yan, X., Gu, Z., Xiu, G., & Xiao, X. (2021) · Electroanalysis · doi:10.1002/elan.202100342 · Cited by 31
Metasurface‐Embedded Contact Lenses for Holographic Light Projection
Ko, J., Kim, G., Kim, I., Hwang, S. H., Jeon, S., Ahn, J., Jeong, Y., Ha, J., Heo, H., Jeong, J., et al. (2024) · Advanced Science · doi:10.1002/advs.202407045 · Cited by 29
CMOS Interfaces for Internet-of-Wearables Electrochemical Sensors: Trends and Challenges
Dei, M., Aymerich, J., Piotto, M., Bruschi, P., del Campo, F. J., & Serra-Graells, F. (2019) · Electronics · doi:10.3390/electronics8020150 · Cited by 30
A low cost, disposable cable-shaped Al–air battery for portable biosensors
Fotouhi, G., Ogier, C., Kim, J., Kim, S., Cao, G., Shen, A. Q., Kramlich, J. C., & Chung, J.-H. (2016) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/5/055011 · Cited by 28
Jeon, C., & Sim, J. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3071300 · Cited by 28
Flash Lamp Annealing Enables Thin-Film Solid-State Batteries on Aluminum Foil
Chen, X., Sastre, J., Aribia, A., Gilshtein, E., & Romanyuk, Y. E. (2021) · ACS Applied Energy Materials · doi:10.1021/acsaem.1c01283 · Cited by 28
Colorimetric Schirmer strip for tear glucose detection
Kang, B., Park, M., & Jeong, K. (2017) · BioChip Journal · doi:10.1007/s13206-017-1405-7 · Cited by 27
Toward transparent and self-activated graphene harmonic transponder sensors
Huang, H., Sakhdari, M., Hajizadegan, M., Shahini, A., Akinwande, D., & Chen, P. (2016) · Applied Physics Letters · doi:10.1063/1.4948254 · Cited by 27
Zhang, X., Lok, M., Tong, T., Lee, S. K., Reagen, B., Chaput, S., Duhamel, P.-E. J., Wood, R. J., Brooks, D. M., & Wei, G.-Y. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2705170 · Cited by 27
Wearables technology for drug abuse detection: A survey of recent advancement
Mahmud, M. S., Fang, H., Carreiro, S., Wang, H., & Boyer, E. W. (2018) · Smart Health · doi:10.1016/j.smhl.2018.09.002 · Cited by 31
A Compact Low-Power Current-to-Digital Readout Circuit for Amperometric Electrochemical Sensors
Yin, H., Ashoori, E., Mu, X., & Mason, A. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2922053 · Cited by 27
Development of an Eye Model With a Physiological Blink Mechanism
Phan, C., Walther, H., Qiao, H., Shinde, R., & Jones, L. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.5.1 · Cited by 27
Spatiotemporal electrochemical sensing in a smart contact lens
Donora, M., Quintero, A. V., Smet, H. D., & Underwood, I. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127203 · Cited by 27
Kim, M., Kim, S., Kwon, Y. W., Seo, H., Chung, W. G., Kim, E., Park, W., Song, H., Lee, D. H., Lee, J., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200049 · Cited by 29
Arata, S., Hayashi, K., Nishio, Y., Kobayashi, A., Nakazato, K., & Niitsu, K. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.04fm04 · Cited by 26
A 186μW Photoplethysmography-Based Noninvasive Glucose Sensing SoC
Hina, A., & Saadeh, W. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3180893 · Cited by 26
Lin, C., Pratt, B., Honikel, M. M., Jenish, A., Ramesh, B., Alkhan, A., & Belle, J. T. L. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817712526 · Cited by 24
Hu, X., Aggarwal, K., Yang, M. X., Parizi, K. B., Xu, X., Akin, D., Poon, A. S. Y., & Wong, H. ‐. P. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.014031 · Cited by 24
Niitsu, K., Kobayashi, A., Ogawa, Y., Nishizawa, M., & Nakazato, K. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348434 · Cited by 23
Towards Closed-Loop Integration of Point-of-Care Technologies
Tan, E. K. W., Au, Y. Z., Moghaddam, G. K., Occhipinti, L. G., & Lowe, C. R. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.12.004 · Cited by 24
Amirghasemi, F., & Kassegne, S. (2021) · Journal of Electronic Materials · doi:10.1007/s11664-020-08681-y · Cited by 23
Holographic contact lens display that provides focusable images for eyes
Sano, J., & Takaki, Y. (2021) · Optics Express · doi:10.1364/oe.419604 · Cited by 23
Soltani, N., ElAnsary, M., Xu, J., Filho, J. S., & Genov, R. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3125618 · Cited by 22
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms
Chiu, W., Chang, T. M., Sone, M., HOSODA, H., Tixier‐Mita, A., & Toshiyoshi, H. (2021) · Electrochem · doi:10.3390/electrochem2020025 · Cited by 21
Cheng, H., Yu, T., & Luo, C. (2013) · IET Microwaves Antennas & Propagation · doi:10.1049/iet-map.2012.0372 · Cited by 21
Cellular Wireless Energy Harvesting for Smart Contact Lens Applications [Education Corner]
Chen, L., Milligan, B., Qu, T., Jeevananthan, L., Shaker, G. S. A., & Safavi‐Naeini, S. (2018) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2018.2859200 · Cited by 21
Cost-efficient Printing of Graphene Nanostructures on Smart Contact Lenses.
Tang, H.-D., Alqattan, B., Jackson, T., Pikramenou, Z., Sun, X.-W., Wang, K., & Butt, H. (2020) · ACS Applied Materials and Interfaces · doi:10.1021/acsami.9b21300 · Cited by 19
Adhikari, P. R., Reid, R. C., & Mahbub, I. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.230726 · Cited by 20
Wireless Biological Electronic Sensors
Cui, Y. (2017) · Sensors · doi:10.3390/s17102289 · Cited by 20
Kang, J., Chiang, P. Y., & Natarajan, A. S. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2868077 · Cited by 20
On-Chip CMOS-MEMS-Based Electroosmotic Flow Micropump Integrated With High-Voltage Generator
Okamoto, Y., Ryoson, H., Fujimoto, K., Ohba, T., & Mita, Y. (2019) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2019.2953290 · Cited by 21
Smart Contact Lens Applied to Gaze Tracking
Massin, L., Seguin, F., Nourrit, V., Daniel, E., Tocnaye, J.-L. D. B. D. L., & Lahuec, C. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3012710 · Cited by 20
Development of an In Vitro Blink Model for Ophthalmic Drug Delivery
Phan, C., Shukla, M. R., Walther, H., Heynen, M., Suh, D., & Jones, L. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13030300 · Cited by 22
An Integrated RF-Powered Wake-Up Wireless Transceiver With –26 dBm Sensitivity
Karami, M. A., & Moez, K. K. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3116208 · Cited by 20
A Power-efficient Bidirectional Potentiostat-based Readout IC for Wide-range Electrochemical Sensing
Tsai, J.-H., Chen, Y., & Liao, Y. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351107 · Cited by 20
Self-citationNiitsu, K., Ando, T., Kobayashi, A., & Nakazato, K. (2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.01ah04 · Cited by 19
Evolution of Biotelemetry in Medical Devices: From Radio Pills to mm-Scale Implants
Valente, V. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3190767 · Cited by 22
A 30 $\mu\text{W}$ Remotely Powered Local Temperature Monitoring Implantable System
Ghanad, M. A., Green, M. M., & Dehollain, C. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2574895 · Cited by 19
21st century citation analysis of the field of contact lenses
Efron, N., Morgan, P. B., Jones, L., & Nichols, J. J. (2021) · Clinical and Experimental Optometry · doi:10.1080/08164622.2021.1880867 · Cited by 18
Continuous glucose monitoring with a flexible biosensor and wireless data acquisition system
Kim, Y., Saviers, K. R., Fisher, T. S., & Irazoqui, P. P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.08.028 · Cited by 18
Monolithic processing of a layered flexible robotic actuator film for kinetic electronics
Zhang, S., Wang, J., Hayashi, K., & Sassa, F. (2021) · Scientific Reports · doi:10.1038/s41598-021-99500-9 · Cited by 20
Modern noninvasive methods for monitoring glucose levels in patients: a review
Dziergowska, K., Łabowska, M. B., Gąsior‐Głogowska, M., Kmiecik, B., & Detyna, J. D. (2019) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2019-0052 · Cited by 19
A transparent glucose-sensitive double polymerised holographic sensor
Moghaddam, G. K., Margerison, H., Suzuki, J., Blyth, J., & Lowe, C. R. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.009 · Cited by 17
Zhang, J., Kuang, Z., Li, H., Li, S., & Xia, F. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116541 · Cited by 28
Lin, F.-T., Lu, S.-Y., & Liao, Y. (2016) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2016.2546398 · Cited by 17
Self-citationWalther, H., Phan, C., Subbaraman, L. N., & Jones, L. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.2.18 · Cited by 17
Implementation of Sensor RFID: Carrying Sensor Information in the Modulation Frequency
Islam, M. M., Rasilainen, K., & Viikari, V. V. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2446476 · Cited by 16
Hosseinian, H., Hosseini, S., Martinez-Chapa, S. O., & Sher, M. (2022) · Polymers · doi:10.3390/polym14010185 · Cited by 18
Development of an In Vitro Ocular Platform to Test Contact Lenses
Phan, C., Walther, H., Gao, H., Rossy, J., Subbaraman, L. N., & Jones, L. (2016) · Journal of Visualized Experiments · doi:10.3791/53907 · Cited by 16
Reconfigurable Multiparameter Biosignal Acquisition SoC for Low Power Wearable Platform
Kim, J., & Ko, H. (2016) · Sensors · doi:10.3390/s16122002 · Cited by 16
Ghanbari, S., Habibi, M., & Magierowski, S. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2811450 · Cited by 16
A Multichannel Electrochemical Sensor Interface IC for Bioreactor Monitoring
Lin, Q., Sijbers, W., Avdikou, C., Gómez, D., Biswas, D., Tacca, B., & Helleputte, N. V. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3315480 · Cited by 15
Directly integrated all-solid-state flexible lithium batteries on polymer substrate
Yim, H., Yu, S., Baek, S., Sung, Y., & Choi, J. (2020) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.227978 · Cited by 15
Ko, J., Kang, H. J., Ahn, J., Zhao, Z., Jeong, Y., Hwang, S. H., Bok, M., Jeon, S., Gu, J., Ha, J., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c06225 · Cited by 15
Metadata
- Authors
- Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P.
- Affiliations
- National Chung Cheng University (TW)
- University of Washington (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-01
- Volume
- 47
- Issue
- 1
- Pages
- 335-344
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1971775068
- Cited by
- 372
- References
- 19
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 14 · 2023: 19 · 2022: 22 · 2021: 40 · 2020: 36 · 2019: 41 · 2018: 39 · 2017: 30 · 2016: 37 · 2015: 23 · 2014: 24 · 2013: 11 · 2012: 7
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- glucose sensor, contact lenses, wireless power transfer, loop antenna, polymer substrates, low-power CMOS, non-invasive glucose monitoring, continuous health monitoring, energy storage capacitors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.