This paper presents a noninvasive wireless sensor platform for continuous health monitoring. The sensor system integrates a loop antenna, wireless sensor interface chip, and glucose sensor on a polymer substrate. The IC consists of power management, readout circuitry, wireless communication interface, LED driver, and energy storage capacitors in a 0.36-mm2CMOS chip with no external components. The sensitivity of our glucose sensor is 0.18 μA·mm-2·mM-1. The system is wirelessly powered and achieves a measured glucose range of 0.05-1 mM with a sensitivity of 400 Hz/mM while consuming 3 μW from a regulated 1.2-V supply.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While many remain battery-powered, wireless power transfer techniques can further reduce the form factor and invasiveness of these devices4–10.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [9]
In the citing paper
“Further advances for the field came with the demonstration of electrochemical biosensing by the Parviz team114-116. This group investigated different biosensing strategies to achieve good sensitivity, linearity and accuracy.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“Further progress has since been made by embedding a wireless read out chip (2.4 GHz) and by powering with far-field electromagnetic radiation (3μW within 15 cm)116.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
In the citing paper
“(iii) the brittle and rigid materials of the integrated electronic system, such as surface-mounted IC chips and rigid interconnects, which could damage the cornea or the eyelid (20–22);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
Citations
Cites
Global estimates of the prevalence of diabetes for 2010 and 2030
Shaw, J. E., Sicree, R. A., & Zimmet, P. Z. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.007 · Cited by 7,216
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Self-citationBerman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 475
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.2005927 · Cited by 179
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
A 9 $\mu$A, Addressable Gen2 Sensor Tag for Biosignal Acquisition
Yeager, D. J., Zhang, F., Zarrasvand, A., George, N. T., Daniel, T., & Otis, B. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2063930 · Cited by 106
Self-citationA fully integrated RF-powered contact lens with a single element display
Pandey, J., Liao, Y.-T., Lingley, A., Mirjalili, R., Parviz, B., & Otis, B. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081989 · Cited by 96 · cited 1×
“Contact-lens functionality could be greatly expanded by creating heterogeneous systems with embedded electronics and wireless telemetry.”
BackgroundSelf-citationA soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216947 · Cited by 81
Research works printed but not linked: 1
- 2006, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
Cited by
Items 201–300 of 376
Miniaturized Biomedical Implantable Devices
Poon, A. S. Y. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch4 · Cited by 15
Overview of CMOS image sensor use in molecular diagnostics
Devadhasan, J. P., Yoo, I. S., & Kim, S. (2015) · Current Applied Physics · doi:10.1016/j.cap.2015.01.009 · Cited by 15
Tanaka, A., Chen, G., & Niitsu, K. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388802 · Cited by 14
Donora, M., González‐Fernández, E., Quintero, A. V., Smet, H. D., & Underwood, I. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126671 · Cited by 14
Three-Dimensionally Printed Interconnects for Smart Contact Lenses
Kim, H., Kim, J., Kang, J., & Song, Y. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b08675 · Cited by 14
Challenges of ambient WiFi backscatter systems in healthcare applications
Lu, X., Yang, Y., & Gong, W. (2024) · Computer Networks · doi:10.1016/j.comnet.2024.110608 · Cited by 13
Wireless power charger for wearable medical devices with in‐band communication
Moon, Y., Park, J., Jeong, M., Kim, S., Kang, J.-G., Kim, D.-Z., & Yoo, C. (2015) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2173 · Cited by 13
Cheng, H., Jeng, B., Chen, C., Huang, H., Chiou, J., & Luo, C. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610283 · Cited by 13
Kobayashi, A., Ikeda, K., Nakazato, K., & Niitsu, K. (2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.01ah03 · Cited by 13
An Area-Efficient Rectifier with Threshold Voltage Cancellation for Intra-Body Power Transfer
Cho, H., Suh, J.-H., Shin, H., Jeon, Y., Jung, C., & Je, M. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702391 · Cited by 13
Kobayashi, A., Hayashi, K., Arata, S., Murakami, S., Bui, C. D., Quan, T. M., Islam, M. Z., & Niitsu, K. (2019) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs46596.2019.8965102 · Cited by 13
Karami, M. A., & Moez, K. K. (2021) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2021.3107149 · Cited by 13
Metamaterial-enhanced near-field readout platform for passive microsensor tags
Wu, K., Duan, G., Zhao, X., Chen, C., Anderson, S. W., & Zhang, X. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00356-4 · Cited by 13
A current-mode potentiostat for multi-target detection tested with different lactate biosensors
Ghoreishizadeh, S. S., Taurino, I., Carrara, S., & Micheli, G. D. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418403 · Cited by 13
A miniaturized implantable loop antenna at MICS and ISM bands for biomedical applications
Lei, W., & Guo, Y. (2013) · IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications · doi:10.1109/imws-bio.2013.6756212 · Cited by 13
Data Reliability and Quality in Body Area Networks for Diabetes Monitoring
Huzooree, G., Khedo, K. K., & Joonas, N. (2018) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-00865-9_4 · Cited by 15
Bio-chemical markers of chronic, non-infectious disease in the human tear film
Alotaibi, S., Markoulli, M. P., Ozkan, J., & PAPAS, E. B. (2021) · Clinical and Experimental Optometry · doi:10.1080/08164622.2021.1974282 · Cited by 14
Qiao, H., Phan, C., Walther, H., Subbaraman, L. N., & Jones, L. (2017) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000397 · Cited by 13
Sim, J. H., Chae, H., Kim, S.-B., Shin, S., Hong, H. K., Cho, H., Jung, Y. H., Lee, D., Kim, M., Hahn, S., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c18563 · Cited by 12
Circural Planner Inverted-F Antenna for Implantable Biomedical Applications
Ali, M. M., Bashar, M. E. I., & Hosain, M. K. (2017) · International Conference on Electrical & Electronic Engineering (ICEEE) · doi:10.1109/ceee.2017.8412844 · Cited by 12
Niitsu, K. (2018) · Japanese Journal of Applied Physics · doi:10.7567/jjap.57.1002a5 · Cited by 12
A resonant current-mode wireless power transfer for implantable medical devices: an overview
Kim, J., Hassan, N. U., Lee, S., Jung, Y.-W., & Shin, S.-U. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00231-1 · Cited by 12
Khan, N. U., Ullah, S., Khan, F. U., & Merla, A. (2024) · Sensors · doi:10.3390/s24102986 · Cited by 12
Paper integrated microfluidic contact lens for colorimetric glucose detection
İşgör, P. K., Abbasiasl, T., Das, R., Istif, E., Yener, U. C., & Beker, L. (2024) · Sensors & Diagnostics · doi:10.1039/d4sd00135d · Cited by 13
Optimal Design for Symbiotic Wearable Wireless Sensors
Bagade, P., Banerjee, A., & Gupta, S. K. S. (2014) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2014.31 · Cited by 12
Ambient electromagnetic energy harvesting system for on‐body sensors
Shaker, G. S. A., Chen, R., Milligan, B., & Qu, T. (2016) · Electronics Letters · doi:10.1049/el.2016.3123 · Cited by 12
SEMON: Sensorless Event Monitoring in Self-Powered Wireless Nanosensor Networks
Zarepour, E., Hassan, M., Chou, C. T., & Adesina, A. A. (2017) · ACM Transactions on Sensor Networks · doi:10.1145/3064838 · Cited by 12
Hayashi, K., Arata, S., Xu, G., Murakami, S., Bui, C. D., Kobayashi, A., & Niitsu, K. (2019) · IEICE Transactions on Electronics · doi:10.1587/transele.2018cts0005 · Cited by 12
Batteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel
Lee, H., Lee, J., Park, H., Nam, M. S., Heo, Y. J., & Kim, S. (2021) · Sensors · doi:10.3390/s21248464 · Cited by 12
Electrochemical miniaturized devices
Dei, M., & Muñoz, F. X. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823727-4.00014-6 · Cited by 11
Bimetallic Electrocatalyst of Hyaluronate-Au@Pt for Durable Oxygen Reduction in Biofuel Cells
Han, H. H., Jung, S., Kim, S., Lee, G., Kim, S., Kim, Y., & Hahn, S. K. (2022) · ACS Applied Energy Materials · doi:10.1021/acsaem.2c02091 · Cited by 11
Aymerich, J., Ferrer-Vilanova, A., Cisneros-Fernández, J., Escudé‐Pujol, R., Guirado, G., Terés, L., Dei, M., Muñoz‐Berbel, X., & Serra-Graells, F. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115342 · Cited by 11
Smart contact lens using passive structures
Tinku, S., Collini, C., Lorenzelli, L., & Dahiya, R. (2014) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2014.6985453 · Cited by 11
Evidence-Based Development Approach for Safe, Sustainable and Secure Mobile Medical App
Bagade, P., Banerjee, A., & Gupta, S. K. S. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_6 · Cited by 11
Andersen, E., Casados, C., Truong, B. D., & Roundy, S. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3104787 · Cited by 10
Yang, C., Chen, S., Zou, Y., Ren, Y., Wang, Z., Xiao, K., Junior, A. G. L., Kumar, S., & Min, R. (2025) · Soft Science · doi:10.20517/ss.2025.44 · Cited by 13
A configurable IC to contol, readout, and calibrate an array of biosensors
Ghoreishizadeh, S. S., Carrara, S., & Micheli, G. D. (2013) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2013.6662331 · Cited by 9
Intra-Body Wireless Power and Data Links for Biomedical Microsystems
Chen, W., Gao, C., Zhu, Y., Lin, L., & Li, J. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388442 · Cited by 10
Application of class D power amplifiers in low power potentiostat circuits
Habibi, M., & Ghanbari, S. (2016) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2240 · Cited by 9
Arata, S., Hayashi, K., Xu, G., Murakami, S., Bui, C. D., Kobayashi, A., & Niitsu, K. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/aafc9e · Cited by 9
Design of Miniaturized Antenna and Power Harvester Circuit on the Enucleated Porcine Eyes
Cheng, H.-W., Yu, T.-C., Huang, H.-Y., Ting, S.-H., Huang, T., Chiou, J., & Luo, C. (2014) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2014.2328611 · Cited by 9
EcoMicro: A Miniature Self-Powered Inertial Sensor Node Based on Bluetooth Low Energy
Lee, C.-T., Liang, Y.-H., Chou, P. H., HeydariGorji, A., Safavi, S. M., Shih, W.-C., & Chen, W.-T. (2018) · International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1145/3218603.3218648 · Cited by 9
Li, Z., Yang, C., Zhang, Y., Wang, T.-H., Chang, Z., Zhu, B., Zhou, L., Luo, Y., Su, B., & Zhao, B. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3244173 · Cited by 8
Liana, Z., Choudhuri, B., & Bhowmick, B. (2023) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2023.3319168 · Cited by 8
Peddi, A., & Ramana, T. V. (2022) · International Journal of Nanotechnology · doi:10.1504/ijnt.2022.10046771 · Cited by 8
Recent developments in minimally and truly non-invasive blood glucose monitoring techniques
Choi, H. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234291 · Cited by 8
CMOS body dust — Towards drinkable diagnostics
Snoeijs, J., Georgiou, P., & Carrara, S. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325215 · Cited by 8
A Power-Harvesting CGM Chiplet Featuring Silicon-Based Enzymatic Glucose Sensor
Wang, T.-H., Li, Z., Liang, B., Cai, Y., Wang, Z., Yang, C., Luo, Y., Sun, J., Ye, X., Chen, Y., et al. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871755 · Cited by 8
Sub-mW reconfigurable interface IC for electrochemical sensing
Ghoreishizadeh, S. S., Boero, C., Pullini, A., Baj-Rossi, C., Carrara, S., & Micheli, G. D. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981705 · Cited by 8
Challenges for wearable healthcare services
Kim, W. D., & Choi, J. (2016) · International Journal of Web and Grid Services · doi:10.1504/ijwgs.2016.080141 · Cited by 8
Helgason, R., Campigotto, A., & Lai, Y. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aba226 · Cited by 8
Review—Power Approaches for Biosensors based Bio-Medical Devices
Gifta, G., & Rani, D. G. N. (2020) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/abcdfd · Cited by 12
Tokuda, T., Kawamura, T., Masuda, K., Hirai, T., Takehara, H., Ohta, Y., Motoyama, M., Takehara, H., Noda, T., Sasagawa, K., et al. (2016) · IEEE Design and Test · doi:10.1109/mdat.2016.2560137 · Cited by 7
Niitsu, K., Ikeda, K., Muto, K., & Nakazato, K. (2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.01ah06 · Cited by 7
Raiff, B. R., Burrows, C. A., & Dwyer, M. J. (2020) · Behavior Analysis in Practice · doi:10.1007/s40617-020-00488-x · Cited by 7
All-printed multiplexed electrocatalytic biosensors with rationally designed nanoparticle inks
Li, X., Yang, M., Rao, A., Su, Y., Yang, T., Ye, Y., Wang, J., Pan, S., Chen, F., Wang, B., et al. (2023) · Nanotechnology · doi:10.1088/1361-6528/acd34e · Cited by 7
Recent Development on Sensing Strategies for Small Molecules Detections
Saleem, M., Hanif, M., Rafiq, M., Ali, A., Raza, H., Kim, S. J., & Lu, C. (2023) · Journal of Fluorescence · doi:10.1007/s10895-023-03387-w · Cited by 7
Karim, A., Nordin, A. N., & Begum, S. (2014) · Elsevier eBooks · doi:10.1016/b978-0-08-096532-1.01322-4 · Cited by 7
A low switching frequency AC-DC boost converter for wireless powered miniaturized implants
Jiang, H., Lariviere, B. A., Lan, D., Zhang, J., Wang, J., Fechter, R., Harrison, M. R., & Roy, S. (2014) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2014.6827739 · Cited by 7
3.34 Biomaterials Challenges in Continuous Glucose Monitors In Vivo
Rao, A. N., Avula, M., & Grainger, D. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09314-0 · Cited by 10
Khan, A. S., & Khan, F. U. (2021) · Journal of Sensors · doi:10.1155/2021/9976089 · Cited by 7
Hsu, C.-C., Chung, W.-Y., Chang, C.-Y., Wu, C., & Lee, C. (2023) · Sensors · doi:10.3390/s23062990 · Cited by 7
The revolution of glucose monitoring methods and systems: A survey
Bayasi, N., Saleh, H. H., Mohammad, B. S., & Ismail, M. (2013) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2013.6815358 · Cited by 7
Cavitas Sensors (Soft Contact Lens Type Biosensor, Mouth-Guard Type Sensor, etc.) for Daily Medicine
Arakawa, T., & Mitsubayashi, K. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-47319-2_3 · Cited by 8
Rectangular Patch Antenna Strain Sensor with Plastic Substrate for Curvature Measurements
Ossa, O., & Lopez, F. E. (2018) · IEEE Latin America Transactions · doi:10.1109/tla.2018.8408428 · Cited by 7
Maximizing Wireless Power Transfer to Intraocular Implants Under Unconstrained Eye Movements
Akinin, A., Ford, J. M., Wu, J., Park, J., Thacker, H. D., Cauwenberghs, G., & Mercier, P. P. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441436 · Cited by 7
Xiong, L., Wan, S., Chen, C.-Y., & Yu, J. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116914 · Cited by 6
Cheong, Y. J., Ramiah, H., Lian, W. X., Lee, Y. C., Churchill, K. K. P., & Chen, Y. (2025) · IEEE Access · doi:10.1109/access.2025.3632861 · Cited by 6
Fedtschenko, T., Utz, A., Stanitzki, A., Hennig, A., Lüdecke, A., Haas, N., & Kokozinski, R. (2019) · Sensors · doi:10.3390/s19194110 · Cited by 6
Islam, M. Z., Matsuyama, N., Chen, G., Kobayashi, A., MOMOI, Y., & Niitsu, K. (2020) · Electrochemistry · doi:10.5796/electrochemistry.20-00044 · Cited by 6
Wearable and Fexible Sensor Sheets toward Periodic Health Monitoring
Takei, K. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_7 · Cited by 6
The Emerging Wearable Solutions in mHealth
Zhao, F., Li, M., & Tsien, J. Z. (2016) · InTech eBooks · doi:10.5772/63557 · Cited by 6
Highly Integrated MEMS-ASIC Sensing System for Intracorporeal Physiological Condition Monitoring
Xue, N., Wang, C., Liu, C., & Sun, J. (2018) · Sensors · doi:10.3390/s18010107 · Cited by 6
RF Harvesting System for Low-Power Applications Using FinFETs
Nagateja, T., Srinivasulu, A., & Pal, D. (2019) · International Conference on Consumer Electronics · doi:10.1109/icce.2019.8661838 · Cited by 6
Ensworth, J. F. (2016) · ResearchWorks at the University of Washington (University of Washington) · Cited by 6
Pan, Y., Cheng, Y., Wu, J., & Qi, H. (2025) · Talanta · doi:10.1016/j.talanta.2025.128732 · Cited by 6
The Evolution and Integrated Systems of Microbatteries
Wang, S., Xu, H., Song, X., Gu, Y., & Yu, L. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202524957 · Cited by 12
Niitsu, K., Kobayashi, A., Yoshida, K., & Nakazato, K. (2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.01ah05 · Cited by 5
Zhang, H., Li, H., Zhang, S., Zhang, Y., Shen, L., Tan, Z., & Ye, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3221891 · Cited by 5
Rieger, S. B., Pfau, J., Stieglitz, T., Asplund, M., & Ordonez, J. S. (2016) · Sensors · doi:10.3390/s17010059 · Cited by 5
Inter-Technology Backscatter: Towards Internet Connectivity for Implanted Devices
Iyer, V., Talla, V., Kellogg, B., Smith, J. R., & Gollakota, S. (2017) · GetMobile Mobile Computing and Communications · doi:10.1145/3161587.3161597 · Cited by 6
Resonant Type RF Glucose Biosensors
Camli, B., & Yalcinkaya, A. D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00011-x · Cited by 5
Low-Noise Current Readout Circuits: A tutorial overview
Assche, J. V., & Anders, J. (2025) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2025.3579705 · Cited by 4
Awano, K., Wu, Y., Okamura, K., Ono, T., Sakamoto, K., Kitaike, H., Tagawa, H., Nakamura, J., Kaneko, M., Kimura, Y., et al. (2025) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas64004.2025.10966300 · Cited by 4
Nanoparticles-Based Flexible Wearable Sensors for Health Monitoring Applications
Nag, A., & Mukhopadhyay, S. C. (2019) · Springer eBooks · doi:10.1007/978-3-662-59600-5_9 · Cited by 5
Jang, S., Wang, Y., & Jang, A. (2022) · Springer series on bio- and neurosystems · doi:10.1007/978-3-030-99728-1_2 · Cited by 4
Li, Z., Miao, X., Li, J., Lee, J., Li, X., Ahn, H., Wu, A., Zhao, W., Yun, J., & Lee, S. W. (2025) · ACS Nano · doi:10.1021/acsnano.5c05610 · Cited by 5
A CMOS ISFET array for wearable thermoelectrically powered perspiration analysis
Douthwaite, M., Moser, N., Koutsos, E., Yates, D. C., Mitcheson, P. D., & Georgiou, P. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833723 · Cited by 4
Chen, Y., Lu, S.-Y., Tsai, J.-H., & Liao, Y. (2019) · International Symposium on VLSI Design, Automation and Test · doi:10.1109/vlsi-dat.2019.8741529 · Cited by 4
Self-citationPaper No 3.1: A Contact Lens With Built‐In Display: Science Fiction or Not?
Smet, H. D., Smet, J. D., Cuypers, D., Weng, C., & Joshi, P. (2013) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.3 · Cited by 4
Simple oscillators-based readout circuit for low-power biomedical implant system
Zhu, K., ISLAM, S. K., Haider, M. R., Roknsharifi, M., & Holleman, J. H. (2012) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-012-9882-z · Cited by 4
A single-chip wireless microelectrode array for neural recording and stimulation
Jou, A. Y.-S., Shan, H., Pajouhi, H., Tsai, M.-S., Ghotbi, S., Wu, Q., Chubykin, A. A., & Mohammadi, S. (2017) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2017.8058833 · Cited by 4
Chen, Y., Lu, S.-Y., & Liao, Y. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702086 · Cited by 4
Self-citationGu, Y., & Takaki, Y. (2024) · Optics Continuum · doi:10.1364/optcon.542400 · Cited by 3
An active rectifier/regulator combo circuit for powering biomedical implants
Lee, E. K. F. (2013) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2013.6658446 · Cited by 3
Biosensing Devices for Personalized Healthcare
Matharu, Z., & Polat, O. (2017) · Springer eBooks · doi:10.1007/978-3-319-63633-7_13 · Cited by 3
CMOS electrochemical measurement circuit for biomolecular detection
Liu, W.-C., Wu, S.-T., Liu, B.-D., & Wei, C. (2018) · International Journal of Electronics · doi:10.1080/00207217.2018.1460872 · Cited by 3
Fedtschenko, T., Utz, A., Stanitzki, A., Hennig, A., Lüdecke, A., Haas, N., & Kokozinski, R. (2018) · International Conference on Sensing Technology · doi:10.1109/icsenst.2018.8603580 · Cited by 3
A temperature sensor with glucose sensor interface based on configurable incremental sigma delta ADC
Chen, X., Li, L., Tan, X., Yan, N., Wang, J., & Zheng, L. (2019) · IEICE Electronics Express · doi:10.1587/elex.16.20181025 · Cited by 3
Finite Element Analysis of Thermoelectric Power Generation from Human Wrist
Hasan, M. N., Hashem, M. Y. B., Siddique, M. A., Yunus, M. A. M., & Ali, M. S. M. (2021) · IEEE Symposium on Industrial Electronics & Applications (ISIEA) · doi:10.1109/isiea51897.2021.9510000 · Cited by 3
Metadata
- Authors
- Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P.
- Affiliations
- National Chung Cheng University (TW)
- University of Washington (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-01
- Volume
- 47
- Issue
- 1
- Pages
- 335-344
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1971775068
- Cited by
- 372
- References
- 19
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 14 · 2023: 19 · 2022: 22 · 2021: 40 · 2020: 36 · 2019: 41 · 2018: 39 · 2017: 30 · 2016: 37 · 2015: 23 · 2014: 24 · 2013: 11 · 2012: 7
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- glucose sensor, contact lenses, wireless power transfer, loop antenna, polymer substrates, low-power CMOS, non-invasive glucose monitoring, continuous health monitoring, energy storage capacitors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.