A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper presents a noninvasive wireless sensor platform for continuous health monitoring. The sensor system integrates a loop antenna, wireless sensor interface chip, and glucose sensor on a polymer substrate. The IC consists of power management, readout circuitry, wireless communication interface, LED driver, and energy storage capacitors in a 0.36-mm2CMOS chip with no external components. The sensitivity of our glucose sensor is 0.18 μA·mm-2·mM-1. The system is wirelessly powered and achieves a measured glucose range of 0.05-1 mM with a sensitivity of 400 Hz/mM while consuming 3 μW from a regulated 1.2-V supply.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While many remain battery-powered, wireless power transfer techniques can further reduce the form factor and invasiveness of these devices4–10.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [9]
In the citing paper
“Further advances for the field came with the demonstration of electrochemical biosensing by the Parviz team114-116. This group investigated different biosensing strategies to achieve good sensitivity, linearity and accuracy.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“Further progress has since been made by embedding a wireless read out chip (2.4 GHz) and by powering with far-field electromagnetic radiation (3μW within 15 cm)116.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [116]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
In the citing paper
“(iii) the brittle and rigid materials of the integrated electronic system, such as surface-mounted IC chips and rigid interconnects, which could damage the cornea or the eyelid (20–22);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [20]
Citations
Cites
Global estimates of the prevalence of diabetes for 2010 and 2030
Shaw, J. E., Sicree, R. A., & Zimmet, P. Z. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.007 · Cited by 7,216
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Self-citationBerman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 475
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.2005927 · Cited by 179
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
A 9 $\mu$A, Addressable Gen2 Sensor Tag for Biosignal Acquisition
Yeager, D. J., Zhang, F., Zarrasvand, A., George, N. T., Daniel, T., & Otis, B. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2063930 · Cited by 106
Self-citationA fully integrated RF-powered contact lens with a single element display
Pandey, J., Liao, Y.-T., Lingley, A., Mirjalili, R., Parviz, B., & Otis, B. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081989 · Cited by 96 · cited 1×
“Contact-lens functionality could be greatly expanded by creating heterogeneous systems with embedded electronics and wireless telemetry.”
BackgroundSelf-citationA soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1216947 · Cited by 81
Research works printed but not linked: 1
- 2006, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
Cited by
Items 301–376 of 376
Biocatalytic Sensors: Potentials, Maxims and Mechanisms for Optimal Performance
Sanni, S. E., Sadiku, E. R., Okoro, E. E., Oni, B. A., & Ndubuisi, A. O. (2023) · Springer eBooks · doi:10.1007/978-981-19-8501-0_6 · Cited by 3
Thin film biosensors for medical diagnostics: Journey so far
Bhattacharyya, N., Jain, S., Bhattacharyya, S., Pal, S., Jana, A., & Mukherjee, S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00058-3 · Cited by 3
The Heterogeneous Packaging of A 3 × 3 Mini‐LED Array for Smart Contact Lens Display Applications
Tsai, C., Yeh, G., Hsu, S., Wu, S., Huang, Y., Chiueh, H., & Chiou, J. (2024) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.24007 · Cited by 3
A feed-forward controlled AC-DC boost converter for biomedical implants
Jiang, H., Lan, D., Lin, D., Zhang, J., Liou, S. P., Shahnasser, H., Shen, M., Harrison, M. R., & Roy, S. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346269 · Cited by 3
4.3 μW 10 fA‐sensitivity dual‐mode current converter for implantable glucose monitoring
Tan, X., Chen, X., Zhang, Y., Wang, J., Min, H., Huang, Y., & Mason, A. J. (2015) · Electronics Letters · doi:10.1049/el.2015.2238 · Cited by 3
A low-power oscillator-based readout interface for medical ultrasonic sensors
Cheng, T.-C., Hsu, C.-W., Wang, H., & Tsai, T. (2016) · International Symposium on VLSI Design, Automation and Test · doi:10.1109/vlsi-dat.2016.7482523 · Cited by 3
Roh, H., Min, Y., Jeon, C., & Sim, J. (2026) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2026.3656705 · Cited by 2
Guowei, C. H. E. N., Chen, X., & Niitsu, K. (2022) · IEICE Transactions on Electronics · doi:10.1587/transele.2021cts0001 · Cited by 2
A mm-sized implantable glucose sensor using a fluorescent hydrogel
Lee, H., Park, H., Kim, T., Nam, M. S., Heo, Y. J., & Kim, S. (2023) · Digest of papers - IEEE Radio Frequency Integrated Circuits Symposium · doi:10.1109/rfic54547.2023.10186146 · Cited by 2
Analytical Equivalent Circuit Extraction of Foreign Metal Objects in WPT Systems
Shirai, R., 中尾, 悟., & Hashimoto, M. (2024) · IEEE Access · doi:10.1109/access.2024.3500008 · Cited by 2
Yuan, M. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-031-52834-7_7 · Cited by 2
An energy-efficient implant transponder for continuous glucose monitoring
Trung, N. T., & Hafliger, P. D. (2013) · International Conference on Advanced Technologies for Communications · doi:10.1109/atc.2013.6698134 · Cited by 2
Low power potentiostat using switching technique for three electrode amperometric sensors
Ghanabri, S., & Habibi, M. (2015) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2015.7146387 · Cited by 2
Inverter based readout circuit for implanted glucose sensor
Thanh, T. N., & Hafliger, P. D. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418449 · Cited by 2
39 fJ/bit On-Chip Identification ofWireless Sensors Based on Manufacturing Variation
Bolus, J. F., Calhoun, B. H., & Blalock, T. N. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4030252 · Cited by 2
High resolution reconfigurable bio-potential processor for portable biomedical application
Senapati, B., Moganti, G. L. K., & Ray, K. B. (2017) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic.2017.8074004 · Cited by 2
Teutsch, T., Mesch, M., Giessen, H. W., & Tarín, C. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.913 · Cited by 2
Design Challenges in Wireless Sensors for Dental Applications
Albasha, L., Qaddoumi, N. N., Hatahet, B., Quadir, N. A., & Taghadosi, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-93100-5_7 · Cited by 2
Tan, J., & Sommer, R. (2019) · International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design · doi:10.1109/smacd.2019.8795258 · Cited by 2
Park, J., Park, J.-H., & Jung, S. (2020) · Sensors · doi:10.3390/s20020493 · Cited by 2
Guowei, C. H. E. N., & Niitsu, K. (2022) · IEICE Transactions on Electronics · doi:10.1587/transele.2021cds0002 · Cited by 2
Applications for biofuel cells
Rao, X., Zhao, P., Yu, Y., & Dong, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13835-5.00004-8 · Cited by 1
A multi-parameter analog-front-end circuit for liquid metal flexible sensor
Li, Z., Wang, X., Liu, M., Liu, W., Liu, W., Hou, Y., & Liu, Y. (2024) · Microelectronics Journal · doi:10.1016/j.mejo.2024.106513 · Cited by 1
Synergizing technology and optics: Exploring the wonders of bioelectronics contact lenses
Abdulamiery, A. A., Shaker, L. M., & Al‐Amiery, A. A. (2025) · Next Materials · doi:10.1016/j.nxmate.2025.101399 · Cited by 1
CMOS Potentiostats for Electrochemical Biosensors: Recent Architectures and Emerging Applications
Alkhalifa, I. M., Eskandari, R., Sawan, M., & Salama, K. N. (2026) · IEEE Sensors Reviews · doi:10.1109/sr.2026.3683992 · Cited by 1
Gao, L., Dong, J., & Wang, Y. (2026) · Chemosensors · doi:10.3390/chemosensors14060140 · Cited by 1
Intermittence-Aware Speculative Page Coloring for Secure NVM
Choi, J., Park, J., L’Heureux, N., Solihin, Y., Joe, H., & Jung, C. (2026) · Proceedings - International Symposium on Computer Architecture/Proceedings · doi:10.1109/isca66397.2026.00088 · Cited by 1
Direct‐Electron‐Transfer‐Based Enzymatic Fuel CellsIn Vitro,Ex Vivo, andIn Vivo
Falk, M., Pankratov, D., Blum, Z., & Shleev, S. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch15 · Cited by 1
Multitasking on Wireless Sensor Networks
Szczodrak, M. (2015) · doi:10.7916/d8sq8zfv · Cited by 1
Concept for assembling individual nanostructure-based components into complex devices
Suyatin, D. B., Sundberg, R., Maximov, I. A., Shleev, S., & Montelius, L. (2015) · Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena · doi:10.1116/1.4931952 · Cited by 1
Evidence-based Development of Trustworthy Mobile Medical Apps
Bagade, P. (2015) · Cited by 1
Optimization Techniques for Miniaturized Integrated Electrochemical Sensors
Mujeeb-U-Rahman, M., & Scherer, A. (2015) · CaltechAUTHORS (California Institute of Technology) · Cited by 1
Hayashi, K., Arata, S., Xu, G., Murakami, S., Bui, C. D., Doike, T., Matsunaga, M., Kobayashi, A., & Niitsu, K. (2019) · Asia and South Pacific Design Automation Conference (ASP-DAC) · doi:10.1145/3287624.3287753 · Cited by 1
70‐4: Late‐News Paper: Electronic Contact Lens for Senses beyond Sight
Donora, M., & Underwood, I. (2019) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.13094 · Cited by 1
Highly Linear Amperometric Glucose Detection System Realized in Deep Submicron CMOS Technology
Wang, H., Shamsir, S., Mahbub, I., ISLAM, S. K., Legassey, A., Gudlavalleti, R. H., Papadimitrakopoulos, F., & Jain, F. (2019) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2019.8802132 · Cited by 1
Backscatter Communication for Biomedical Devices
Aberra, A., Kim, Y.-H., Je, M., & Ha, S. (2022) · Springer eBooks · doi:10.1007/978-1-4614-3447-4_39 · Cited by 1
Raedt, W. D., & Hoof, C. A. V. (2017) · Wiley eBooks · doi:10.1002/9783527800728.ch19 · Cited by 1
Al‐Worafi, Y. M. (2022) · CRC Press eBooks · doi:10.1201/9781003230458-20 · Cited by 1
Wan, H., Meng, Y., Wang, Z., & Du, Z. (2024) · Review of Scientific Instruments · doi:10.1063/5.0192761 · Cited by 1
Application of Computational Tear Flow Models to Smart Contact Lens Design
Ashley, R. C., Fida, M., Li, J., & Ly, J. (2014)
A low-power 0.5V regulator with settling enhancement for wireless sensor nodes
Wen, F.-C., Hsu, H.-S., Hong, Z.-H., & Liao, Y. (2013) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2013.6572258
Self-citationDreshfield, D. A. (2012) · Scholarship - Claremont (Claremont Colleges)
UNIVERSIDADE FEDERAL DE SANTA CATARINA PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA
Martins, G. C. (2013)
Glucose Sensor and Its Potential Directions
Cheng, C., Kuan, C.-M., & Chen, C. (2015) · Springer eBooks · doi:10.1007/978-3-319-19737-1_4
Antifungal ocular drug delivery via contact lenses using a novel in vitro eye model
Phan, C. (2016) · UWSpace (University of Waterloo)
12 Wearable Nanoenabled Biosensors
Singh, A., Pasha, S. K., & Bhansali, S. (2016) · doi:10.1201/9781315366425-13
Energy-Autonomous Supply-Sensing Biosensor Platform Using CMOS Electronics and Biofuel Cells
Niitsu, K. (2017) · Springer eBooks · doi:10.1007/978-3-319-55345-0_2
Introduction to Electrochemical Point-of-Care Devices
Punter-Villagrasa, J., Colomer‐Farrarons, J., del Campo, F. J., & Miribel‐Català, P. L. (2017) · Bioanalysis · doi:10.1007/978-3-319-64801-9_1
Tran, S. (2017) · DigitalCommons - CalPoly (California State Polytechnic University) · doi:10.15368/theses.2017.57
Contact Lenses and Tear Film Lipids.
Walther, H. (2017) · UWSpace (University of Waterloo)
AEVUM: Personalized Health Monitoring System
Swaminathan, A. (2018) · RIT Scholar Works (Rochester Institute of Technology) · Cited by 1
Choi, M. (2018) · Deep Blue (University of Michigan)
Biosensor Integrated System Using CMOS LSI Technology
Niitsu, K. (2018) · IEICE ESS FUNDAMENTALS REVIEW · doi:10.1587/essfr.12.2_133
45-nm SOI CMOS Bluetooth Electrochemical Sensor for Continuous Glucose Monitoring
Muthreja, A. (2018) · UWSpace (University of Waterloo)
Backscatter Communication for Biomedical Devices
Aberra, A., Kim, Y.-H., Je, M., & Ha, S. (2020) · Springer eBooks · doi:10.1007/978-1-4614-6623-9_39-1
Low Power Wireless Protocols and Platforms for Internet of Things
Najafi, A. (2020) · ResearchWorks at the University of Washington (University of Washington)
Shi, W. Y. (2019) · Cited by 1
A 65-nm CMOS 0.4 V 49.6 nW Voltage Monitor for Small-Form-Factor Biomedical IoT Applications
Yu, X., Chen, G., Wang, Y., Chen, X., & Niitsu, K. (2021) · IEEE Asia Pacific Conference on Postgraduate Research in Microelectronics and Electronics (PrimeAsia) · doi:10.1109/primeasia51450.2021.9701468
Juan, C. G. (2021) · Springer theses · doi:10.1007/978-3-030-76179-0_2
Low-power Wearable Healthcare Sensors
Sherratt, R. S., & Dey, N. (2020) · MDPI eBooks · doi:10.3390/books978-3-03936-480-0
Smart Devices in Healthcare Sector: Applications
Sharma, K., Kesharwani, P., Prajapati, S. K., Jain, A., Mittal, N., Kaushik, R., & Mody, N. (2022) · Springer eBooks · doi:10.1007/978-3-030-84205-5_23
“Past” and “Future” of Healthcare Electronics
ヘルスケアエレクトロニクス研究会 (2022) · Journal of The Japan Institute of Electronics Packaging · doi:10.5104/jiep.26.93
Electrochemical glucose biosensors based on microbial whole cells
Aslan, S., Oktay, M. K., & Özen, A. A. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837676408-00027 · Cited by 1
Future applications of contact lenses
Phan, C., Walsh, K., & Jones, L. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-87929-3.00034-7
Huang, X., Jiao, Y., Yang, Y., & Li, J. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch2
Cuypers, D., & Smet, H. D. (2025) · Springer proceedings in physics · doi:10.1007/978-981-96-9782-3_12
A Pole‐Optimized Current‐Domain DT‐DSM With Extended Dynamic Range and High Linearity
He, P., Qiao, Y., Jin, H., Yu, Z., & Gu, X. (2025) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.70225
Awano, K., Sugimura, Y., Ota, Y., Wu, Y., Ogura, K., Kitaike, H., Okamura, K., Xu, S., Nakamura, J., Kaneko, M., et al. (2025) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas67402.2025.11377210
Traitement embarqué sur lentille de contact instrumentée : application à l'oculométrie
Massin, L. (2021) · theses.fr (ABES) · doi:10.70675/3edfdfd0z66bez4631z8f3dz1f26ed418f29
Suzuki, H., & Sassa, F. (2026) · Modern aspects of electrochemistry · doi:10.1007/978-981-95-6483-5_8
Peng, Y., Huang, X., Zhang, X., Jiang, Y., Zhang, X., Zeng, X., Sun, F., Liu, P., Zhou, J., Luo, Z., et al. (2026) · Interdisciplinary medicine · doi:10.1002/inmd.70132
Machine Learning-Based Information Processing for Smart Contact Lens Tear Glucose Sensing
Li, Z. (2026) · World Conference on Computing and Communication Technologies (WCCCT) · doi:10.1109/wccct69960.2026.11549629
Wang, Z., Deng, F., & Fu, H. (2026) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2026.110574
A hybrid voltage-domain and time-domain quantization technique for ultra-low current sensing
Dong, J., Cheng, Q., Qiu, L., Zeng, P., & Yao, B. (2026) · Microelectronics Journal · doi:10.1016/j.mejo.2026.107407
Ocular smart wearable sensors and chips: Summary and outlook
Chen, Y., ZHANG, Y., HUANG, Y., Fan, T. A. N. G., Minghua, D. U., Xinxia, C. A. I., & Yang, W. A. N. G. (2026) · Chinese Journal of Semiconductors · doi:10.3724/cjos.2025.002
Low-power wireless communication technologies empower wearable healthcare monitoring
Na, X., Wu, L., Kong, Q., Cao, W., Fang, X., Wu, Y., Bao, T., & Xie, S. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-03256-3
Metadata
- Authors
- Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P.
- Affiliations
- National Chung Cheng University (TW)
- University of Washington (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-01
- Volume
- 47
- Issue
- 1
- Pages
- 335-344
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1971775068
- Cited by
- 372
- References
- 19
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 14 · 2023: 19 · 2022: 22 · 2021: 40 · 2020: 36 · 2019: 41 · 2018: 39 · 2017: 30 · 2016: 37 · 2015: 23 · 2014: 24 · 2013: 11 · 2012: 7
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- glucose sensor, contact lenses, wireless power transfer, loop antenna, polymer substrates, low-power CMOS, non-invasive glucose monitoring, continuous health monitoring, energy storage capacitors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.