The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Model-Based Image Reconstruction for MRI
Open accessAbstract
Magnetic resonance imaging (MRI) is a sophisticated and versatile medical imaging modality. The inverse FFT has served the MR community very well as the conventional image reconstruction method for k-space data with full Cartesian sampling. And for well sampled non-Cartesian data, the gridding method with appropriate density compensation factors is fast and effective. But when only under-sampled data is available, or when non-Fourier physical effects like field inhomogeneity are important, then gridding/FFT methods for image reconstruction are suboptimal, and iterative algorithms based on appropriate models can improve image quality, rat the price of increased computation. This article reviews the use of iterative algorithms for model-based MR image reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
The Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,282
Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
Golub, G. H., Heath, M., & Wahba, G. (1979) · Technometrics · doi:10.1080/00401706.1979.10489751 · Cited by 3,934
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems
Hansen, P. C., & O’Leary, D. P. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914086 · Cited by 3,137
Sparse Approximate Solutions to Linear Systems
Natarajan, B. K. (1995) · SIAM Journal on Computing · doi:10.1137/s0097539792240406 · Cited by 2,783
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Sparse signal reconstruction from limited data using FOCUSS: a re-weighted minimum norm algorithm
Gorodnitsky, I. F., & Rao, B. D. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.558475 · Cited by 1,834
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Self-citationDeterministic edge-preserving regularization in computed imaging
Charbonnier, P., Blanc-Feraud, L., Aubert, G., & Barlaud, M. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.551699 · Cited by 1,301
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Two deterministic half-quadratic regularization algorithms for computed imaging
Charbonnier, P., Blanc-Feraud, L., Aubert, G., & Barlaud, M. (2002) · Proceedings of 1st International Conference on Image Processing · doi:10.1109/icip.1994.413553 · Cited by 879
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Fessler, J. A., & Rogers, W. L. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.535846 · Cited by 518
Self-citationHomodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$-Minimization
Trzasko, J., & Manduca, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927346 · Cited by 490
Macovski, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360327 · Cited by 420
Principles of Magnetic Resonance Imaging
Liang, Z.-P., & Lauterbur, P. C. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545652 · Cited by 412
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Self-citationRamani, S., Blu, T., & Unser, M. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2001404 · Cited by 397
Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973.
Pc, L. (1989) · PubMed · Cited by 391
Simple Correction Method fork-Space Trajectory Deviations in MRI
Duyn, J. H., Yang, Y., Frank, J. A., & van der Veen, J. W. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1396 · Cited by 359
Rapid gridding reconstruction with a minimal oversampling ratio
Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848376 · Cited by 333
Quantitative evaluation of several partial fourier reconstruction algorithms used in mri
McGibney, G., Smith, M. R., Nichols, S. T., & Crawley, A. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300109 · Cited by 313
Delaney, A. H., & Bresler, Y. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.660997 · Cited by 304
Non-convergence of the L-curve regularization parameter selection method
Vogel, C. R. (1996) · Inverse Problems · doi:10.1088/0266-5611/12/4/013 · Cited by 293
Uecker, M., Hohage, T., Block, K. T., & Frahm, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21691 · Cited by 253
Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction
Fessler, J. A., & Booth, S. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.760336 · Cited by 236
Self-citationNoise and filtration in magnetic resonance imaging
McVeigh, E. R., Henkelman, R. M., & Bronskill, M. J. (1985) · Medical Physics · doi:10.1118/1.595679 · Cited by 222
Stone, M. (1978) · Series Statistics · doi:10.1080/02331887808801414 · Cited by 220
Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction
Brinkmann, B. H., Manduca, A., & Robb, R. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700729 · Cited by 213
Self‐calibrating parallel imaging with automatic coil sensitivity extraction
McKenzie, C. A., Yeh, E. N., Ohliger, M. A., Price, M. D., & Sodickson, D. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10087 · Cited by 189
Biological and medical imaging by NMR
Mansfield, P., & Pykett, I. L. (1978) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(78)90159-2 · Cited by 186
Retrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176
Fessler, J. A., Lee, S.-W., Olafsson, V. T., Shi, H. R., & Noll, D. C. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853152 · Cited by 171
Self-citationFast imaging using subencoding data sets from multiple detectors
Ra, J. B., & Rim, C. Y. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300123 · Cited by 163
Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
Persson, M., Bone, D., & Elmqvist, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/318 · Cited by 161
Postprocessing technique to correct for background gradients in image-basedR*2 measurements
Fernandez-Seara, M., & Wehrli, F. W. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<358::aid-mrm3>3.0.co;2-i · Cited by 160
Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study
Hennig, J., Welz, A. M., Schultz, G., Korvink, J. G., Liu, Z., Speck, O., & Zaitsev, M. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0105-7 · Cited by 145
Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
Tincher, M., Meyer, C. R., Gupta, R., et al. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232267 · Cited by 136
Combination of signals from array coils using image‐based estimation of coil sensitivity profiles
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10092 · Cited by 122
Regularized Field Map Estimation in MRI
Funai, A. K., Fessler, J. A., Yeo, D. T. B., Olafsson, V. T., & Noll, D. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923956 · Cited by 121
Self-citationStockmann, J., Ciris, P. A., Galiana, G., Tam, L., & Constable, R. T. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22425 · Cited by 107
Dynamic field map estimation using a spiral‐in/spiral‐out acquisition
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20079 · Cited by 96
Self-citationConjugate phase MRI reconstruction with spatially variant sample density correction
Noll, D. C., Fessler, J. A., & Sutton, B. P. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.842452 · Cited by 95
Self-citationRik Van De Walle, B., Barrett, H. H., Myers, K. J., Aitbach, M. I., Desplanques, B., Gmitro, A. F., Cornelis, J. P., & Lemahieu, I. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897806 · Cited by 92
Partial fourier partially parallel imaging
Bydder, M., & Robson, M. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20492 · Cited by 90
A Method to measure arbitrary k‐space trajectories for rapid MR imaging
Mason, G. F., Harshbarger, T. B., Hetherington, H. P., Zhang, Y., Pohost, G. M., & Twieg, D. B. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380318 · Cited by 89
Off-resonance correction of MR images
Schomberg, H. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.781014 · Cited by 85
Lin, F., Chen, Y., Belliveau, J. W., et al. (2003) · Human Brain Mapping · doi:10.1002/hbm.10109 · Cited by 82
Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging
Sekihara, K., Kuroda, M., & Kohno, H. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/1/002 · Cited by 76
Magnetic susceptibility quantification for arbitrarily shaped objects in inhomogeneous fields
Li, L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1276 · Cited by 76
Zelinski, A. C., Wald, L. L., Setsompop, K., Alagappan, V., Gagoski, B. A., Goyal, V. K., & Elfar Adalsteinsson, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21585 · Cited by 76
Bayesian parallel imaging with edge‐preserving priors
Raj, A., Singh, G., Zabih, R., Kressler, B., Wang, Y., Schuff, N. W., & Weiner, M. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21012 · Cited by 70
Fast Joint Reconstruction of Dynamic $R_2^*$ and Field Maps in Functional MRI
Olafsson, V. T., Noll, D. C., & Fessler, J. A. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.917247 · Cited by 58
Self-citationLai, S., & Fang, M. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80033-4 · Cited by 40
Parsing local signal evolution directly from a single‐shot MRI signal: A new approach for fMRI
Twieg, D. B. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10613 · Cited by 35
MODEL-BASED MR IMAGE RECONSTRUCTION WITH COMPENSATION FOR THROUGH-PLANE FIELD INHOMOGENEITY
Fessler, J. A., & Noll, D. C. (2007) · IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI) · doi:10.1109/isbi.2007.357003 · Cited by 13
Self-citation
Cited by
Transformers in medical imaging: A survey
Shamshad, F., Khan, S., Zamir, S. W., Khan, M. H., Hayat, M., Khan, F. S., & Fu, H. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102802 · Cited by 1,296
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
Nonlocal Transform-Domain Filter for Volumetric Data Denoising and Reconstruction
Maggioni, M., Katkovnik, V., Egiazarian, K., & Foi, A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2210725 · Cited by 1,002
Deep Learning Techniques for Inverse Problems in Imaging
Ongie, G., Jalal, A., Metzler, C. A., Baraniuk, R. G., Dimakis, A. G., & Willett, R. (2020) · IEEE Journal on Selected Areas in Information Theory · doi:10.1109/jsait.2020.2991563 · Cited by 577
Extracellular matrix in lung development, homeostasis and disease
Zhou, Y., Horowitz, J. C., Naba, A., Ambalavanan, N., Atabai, K., Balestrini, J., Bitterman, P. B., Corley, R. A., Ding, B.-S., Engler, A. J., et al. (2018) · Matrix Biology · doi:10.1016/j.matbio.2018.03.005 · Cited by 284
Metadata
- Authors
- Fessler, J.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2010-07
- Volume
- 27
- Issue
- 4
- Pages
- 81-89
- ISSN
- 1053-5888 (ISSN-L)
- OpenAlex
- W2087332491
- Cited by
- 335
- References
- 69
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.