Control of Hand Prostheses Using Peripheral Information
The DOI matches its Crossref record; 147 of the 147 references it cites were found in a registry or an index.
Abstract
Several efforts have been carried out to enhance dexterous hand prosthesis control by impaired individuals. Choosing which voluntary signal to use for control purposes is a critical element to achieve this goal. This review presents and discusses the recent results achieved by using electromyographic signals, recorded either with surface (sEMG) or intramuscular (iEMG) electrodes, and electroneurographic (ENG) signals. The potential benefits and shortcomings of the different approaches are described with a particular attention to the definition of all the steps required to achieve an effective hand prosthesis control in the different cases. Finally, a possible roadmap in the field is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Internal models for motor control and trajectory planning.
Kawato, M. (1999) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(99)00028-8 · Cited by 2,685
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Comparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Self-citationCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Characterization of a Benchmark Database for Myoelectric Movement Classification
Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328495 · Cited by 293
Building the Ninapro database: A resource for the biorobotics community
Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290287 · Cited by 262
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationCiuti, G., Ricotti, L., Menciassi, A., & Dario, P. (2015) · Sensors · doi:10.3390/s150306441 · Cited by 172
“…a significant role and applicability in synthetic [76] and bio-artificial [77] tactile sensors towards rehabilitation aims in neuroprosthetics [78], for sensing human-machine interaction [79], and for scientific purposes such as investigating and mimicking the human sense of touch [80,81].”
BackgroundOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“Furthermore, sensors embedded in the prosthesis can provide valuable feedback information that currently has no stable means of being naturally transmitted to the patient [4].”
BackgroundSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
Self-citationBadia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2440768 · Cited by 65
“Similar signal processing paradigm has been largely used in the literature and it can be considered an efficient way for signals recorded from muscles (EMG) and peripheral nerves (ENG) [15].”
MethodSelf-citationMotor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
“The amplitude of the action potentials detected by extraneural interfaces is much lower than in the case of intraneural interfaces and depends on the distance of the electrodes from the active axons [12].”
BackgroundMultichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
“EMG Signals Although technically EMG is not a neural signal, we briefly mention it as they are used in commercially available, state-of-the-art myoelectric prostheses [8].”
BackgroundA bioelectric neural interface towards intuitive prosthetic control for amputees
Nguyen, A. T., Xu, J., Jiang, M., Luu, D. K., Wu, T., Tam, W.-K., Zhao, W., Drealan, M. W., Overstreet, C. K., Zhao, Q., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3d3 · Cited by 52
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
Vallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35
Self-citationFani, S., Bianchi, M., Jain, S., Pimenta Neto, J. S., Boege, S., Grioli, G., Bicchi, A., & Santello, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00011 · Cited by 31
Preliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4
Metadata
- Authors
- Micera, S., Carpaneto, J., & Raspopovic, S.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2010
- Volume
- 3
- Pages
- 48-68
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2124502724
- Cited by
- 403
- References
- 147
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.