The DOI matches its Crossref record; 147 of the 147 references it cites were found in a registry or an index.
Control of Hand Prostheses Using Peripheral Information
Abstract
Several efforts have been carried out to enhance dexterous hand prosthesis control by impaired individuals. Choosing which voluntary signal to use for control purposes is a critical element to achieve this goal. This review presents and discusses the recent results achieved by using electromyographic signals, recorded either with surface (sEMG) or intramuscular (iEMG) electrodes, and electroneurographic (ENG) signals. The potential benefits and shortcomings of the different approaches are described with a particular attention to the definition of all the steps required to achieve an effective hand prosthesis control in the different cases. Finally, a possible roadmap in the field is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Internal models for motor control and trajectory planning.
Kawato, M. (1999) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(99)00028-8 · Cited by 2,685
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Hodges, P. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95190-5 · Cited by 983
Multiple neural spike train data analysis: state-of-the-art and future challenges
Brown, E. N., Kass, R. E., & Mitra, P. P. (2004) · Nature Neuroscience · doi:10.1038/nn1228 · Cited by 868
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationSupport Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Galán, F., Nuttin, M., Lew, E., Ferrez, P. W., Vanacker, G., Philips, J., & Millán, J. D. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.001 · Cited by 660
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationOn the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationA Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Kuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Self-citationQuantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Analysis of models for extracellular fiber stimulation
Rattay, F. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32099 · Cited by 420
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationEvaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Merletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Self-citationSurface Electromyography for Noninvasive Characterization of Muscle
Merletti, R., Rainoldi, A., & Farina, D. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200101000-00005 · Cited by 325
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
Clinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
Online Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Kuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 283
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Myoelectric teleoperation of a complex robotic hand
Farry, K. A., Walker, I. D., & Baraniuk, R. G. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538982 · Cited by 248
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
The application of neural networks to myoelectric signal analysis: a preliminary study
Kelly, M. F., Parker, P. A., & Scott, R. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52324 · Cited by 221
Objective motor response onset detection in surface myoelectric signals
Staude, G., & Wolf, W. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00067-3 · Cited by 217
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Onset Detection in Surface Electromyographic Signals: A Systematic Comparison of Methods
Staude, G., Flachenecker, C., Daumer, M., & Wolf, W. (2001) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865701000191 · Cited by 211
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
EMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197
Analysis of intramuscular electromyogram signals
Merletti, R., & Farina, D. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0235 · Cited by 194
A brain-computer interface with vibrotactile biofeedback for haptic information
Chatterjee, A., Aggarwal, V., Ramos, A., Acharya, S., & Thakor, N. V. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-40 · Cited by 194
Modulation of Muscle Synergy Recruitment in Primate Grasping
Overduin, S. A., d'Avella, A., Roh, J., & Bizzi, E. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2869-07.2008 · Cited by 190
Huang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Mapping phantom movement representations in the motor cortex of amputees
Mercier, C. (2006) · Brain · doi:10.1093/brain/awl180 · Cited by 182
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.911817 · Cited by 177
Persistent hand motor commands in the amputees' brain
Reilly, K. T. (2006) · Brain · doi:10.1093/brain/awl154 · Cited by 175
Muscle synergies as a predictive framework for the EMG patterns of new hand postures
Ajiboye, A. B., & Weir, R. F. F. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036004 · Cited by 174
A thin, flexible multielectrode grid for high-density surface EMG
Lapatki, B. G., van Dijk, J. P., Jonas, I. E., Zwarts, M. J., & Stegeman, D. F. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00521.2003 · Cited by 172
Wheeler, J. W., Bark, K., Savall, J., & Cutkosky, M. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039602 · Cited by 168
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
Farrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
Implantable biomedical microsystems for neural prostheses
Stieglitz, T., Schuetter, M., & Koch, K. P. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511501 · Cited by 158
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Diedrich, A., Charoensuk, W., Brychta, R. J., Ertl, A. C., & Shiavi, R. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.807323 · Cited by 138
Solnik, S., DeVita, P., Rider, P. M., Long, B. L., & Hortobágyi, T. (2008) · PubMed · Cited by 135
Der mechanische Aufbau der künstlichen Glieder
Schlesinger, G. (1919) · Springer eBooks · doi:10.1007/978-3-662-33009-8_13 · Cited by 134
Continuous Shared Control for Stabilizing Reaching and Grasping With Brain-Machine Interfaces
Kim, H. K., Biggs, S. J., Schloerb, D. W., Carmena, J. M., Lebedev, M., Nicolelis, M. A. L., & Srinivasan, M. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870235 · Cited by 125
Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine
Liu, Y., Huang, H., & Weng, C.-H. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897253 · Cited by 121
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Self-citationCiti, L., Carpaneto, J., Yoshida, K., Hoffmann, K., Koch, K. P., Dario, P., & Micera, S. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.04.025 · Cited by 120
Self-citationPino, G. D., Guglielmelli, E., & Rossini, P. M. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.03.001 · Cited by 119
Referral of sensation to an advanced humanoid robotic hand prosthesis
Rosén, B., Ehrsson, H. H., Antfolk, C., Cipriani, C., Sebelius, F., & Lundborg, G. (2009) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844310903113107 · Cited by 119
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116
Wang, G., Wang, Z., Chen, W., & Zhuang, J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0100-y · Cited by 113
An algorithm for detecting the onset of muscle contraction by EMG signal processing
Micera, S., Sabatini, A. M., & Dario, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00017-4 · Cited by 109
Self-citationWright, F. V. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181ae9637 · Cited by 107
Micera, S., Citi, L., Rigosa, J., Carpaneto, J., Raspopović, S., Pino, G. D., Rossini, L., Yoshida, K., Denaro, L., Dario, P., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038726 · Cited by 107
Self-citationTopographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
On Surface EMG Spectral Characterization and Its Application to Diagnostic Classification
Inbar, G. F., & Noujaim, A. E. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325303 · Cited by 96
Multichannel thin-film electrode for intramuscular electromyographic recordings
Farina, D., Yoshida, K., Stieglitz, T., & Koch, K. P. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00788.2007 · Cited by 95
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Self-citationFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
SENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 88
Continuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors
Baker, J. J., Scheme, E., Englehart, K. B., Hutchinson, D. T., & Greger, B. E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047590 · Cited by 84
Raspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Self-citationA distributed architecture for activating the peripheral nervous system
Andreu, D., Guiraud, D., & Souquet, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026001 · Cited by 80
Relationship between grasping force and features of single-channel intramuscular EMG signals
Kamavuako, E. N., Farina, D., Yoshida, K., & Jensen, W. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.09.006 · Cited by 79
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78
Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes
Yoshida, K., & Stein, R. B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740885 · Cited by 76
Schoening, H. A. (1986) · Archives of Physical Medicine and Rehabilitation · doi:10.5555/uri:pii:0003999386903758 · Cited by 76
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73
Hybrid Bionic Systems for the Replacement of Hand Function
Micera, S., Carrozza, M. C., Beccai, L., Vecchi, F., & Dario, P. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.881294 · Cited by 73
Self-citationJia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Yoshida, K., Farina, D., Akay, M., & Jensen, W. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038613 · Cited by 61
Schultz, A. E., Marasco, P. D., & Kuiken, T. A. (2009) · Brain Research · doi:10.1016/j.brainres.2008.11.039 · Cited by 58
Artificial touch in a hand-prosthesis
Beeker, T. W., During, J., & den Hertog, A. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478841 · Cited by 55
Aspects of silicone rubber as an encapsulant for neurological prostheses
Donaldson, P. E. K. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446293 · Cited by 53
(2001) · PubMed · Cited by 52
An Electrode for Recording Single Motor Unit Activity During Strong Muscle Contractions
Luca, C. J. D., & Forrest, W. J. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324140 · Cited by 52
Mulvey, M. R., Fawkner, H. J., Radford, H. E., & Johnson, M. I. (2008) · Medical Hypotheses · doi:10.1016/j.mehy.2008.08.028 · Cited by 50
Humans Can Integrate Force Feedback to Toes in Their Sensorimotor Control of a Robotic Hand
Panarese, A., Edin, B. B., Vecchi, F., Carrozza, M. C., & Johansson, R. S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021689 · Cited by 48
Blind source separation of peripheral nerve recordings
Tesfayesus, W., & Durand, D. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s03 · Cited by 45
Problems of bioelectric control
Kobrinskii, A. E., Bolkhovitin, S. V., Voskoboinikova, L. M., Ioffe, D. M., Polyan, E. P., Popov, B. P., Slavutskii, I. L., Sysin, A. J., & Yakobson, Y. S. (1960) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)70141-3 · Cited by 45
Signal Processing for Proportional Myoelectric Control
Evans, H. B., Pan, Z., Parker, P. A., & Scott, R. N. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325330 · Cited by 42
On automatic identification of upper-limb movements using small-sized training sets of EMG signals
Micera, S., Sabatini, A. M., & Dario, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00069-2 · Cited by 40
Self-citationThe wartenweiler memorial lecture the use of surface electromyography in biomechanics
Luca, C. J. D. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)91124-x · Cited by 39
Artificial Sensibility Based on the Use of Piezoresistive Sensors
Lundborg, G., Rosén, B., Lindström, K., & Lindberg, S. (1998) · Journal of Hand Surgery (European Volume) · doi:10.1016/s0266-7681(98)80016-8 · Cited by 37
Chu, J., & Lee, Y.-J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2015177 · Cited by 35
Martelloni, C., Carpaneto, J., & Micera, S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2026470 · Cited by 32
Self-citationShape Memory Alloy Microactuation of tf-LIFEs: Preliminary Results
Bossi, S., Menciassi, A., Koch, K. P., Hoffmann, K., Yoshida, K., Dario, P., & Micera, S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895186 · Cited by 29
Self-citationAn Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves
Bossi, S., Kammer, S., DÖrge, T., Menciassi, A., Hoffmann, K. P., & Micera, S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031169 · Cited by 26
Self-citationPassive Neutralization of Myoelectric Interference From Neural Recording Tripoles
Pachnis, I., Demosthenous, A., & Donaldson, N. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891170 · Cited by 22
Sensory feedback for artificial limbs.
Shannon, G. F. (1979) · PubMed · Cited by 21
Aspects of silicone rubber as encapsulant for neurological prostheses
Donaldson, P. E. K., & Aylett, B. J. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510501 · Cited by 19
Djilas, M., Coste, C., Guiraud, D., & Yoshida, K. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/836346 · Cited by 14
Zhou, R., Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0555-8 · Cited by 8
Hand construction of quadrifilar wire electrodes for electromyography
Ahmed, O. I., & Roark, R. M. (2009) · Muscle & Nerve · doi:10.1002/mus.21469 · Cited by 2
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Comparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Metadata
- Authors
- Micera, S., Carpaneto, J., & Raspopovic, S.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2010
- Volume
- 3
- Pages
- 48-68
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2124502724
- Cited by
- 403
- References
- 147
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.