Spatial and functional selectivity of peripheral nerve signal recording with the transversal intrafascicular multichannel electrode (TIME)
Open accessAbstract
The selection of suitable peripheral nerve electrodes for biomedical applications implies a trade-off between invasiveness and selectivity. The optimal design should provide the highest selectivity for targeting a large number of nerve fascicles with the least invasiveness and potential damage to the nerve. The transverse intrafascicular multichannel electrode (TIME), transversally inserted in the peripheral nerve, has been shown to be useful for the selective activation of subsets of axons, both at inter- and intra-fascicular levels, in the small sciatic nerve of the rat. In this study we assessed the capabilities of TIME for the selective recording of neural activity, considering the topographical selectivity and the distinction of neural signals corresponding to different sensory types. Topographical recording selectivity was proved by the differential recording of CNAPs from different subsets of nerve fibers, such as those innervating toes 2 and 4 of the hindpaw of the rat. Neural signals elicited by sensory stimuli applied to the rat paw were successfully recorded. Signal processing allowed distinguishing three different types of sensory stimuli such as tactile, proprioceptive and nociceptive ones with high performance. These findings further support the suitability of TIMEs for neuroprosthetic applications, by exploiting the transversal topographical structure of the peripheral nerves.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
TIMEs are able to both stimulate and record from separate nerve fascicles within nerves independently.
“TIMEs are able to both stimulate (Badia et al., 2011b) and record from Badia et al. (2016) separate nerve fascicles within nerves independently, and coupled with artificial hand prostheses have been used to restore sensory perception in human hand amputee patients (Raspopovic et al., 2014; D'Anna et al., 2019).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Badia et al., 2016
Previous studies of peripheral implants used for rodents have reported peak-to-peak signal amplitudes ranging from 100-900 μV in response to electrical stimuli.
“Previous studies of peripheral implants used for rodents have reported peak-to-peak signal amplitudes ranging from 100–900 μV in response to electrical stimuli [22–27].”
From A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve (2017) · cites this paper as [26]
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · see citing works
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x_9_4_001 · Cited by 1,372 · see citing works
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · see citing works
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1× · see citing works
“able to activate paralyzed organs by electrical stimulation of adequate spinal roots or nerves, and also to record neural signals from intact segments of the nervous system for providing sensory feedback or detecting central orders [1], [2].”
BackgroundSelf-citationConduction velocity is related to morphological cell type in rat dorsal root ganglion neurones.
Harper, A. A., & Lawson, S. N. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015573 · Cited by 755 · see citing works
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · cited 3× · see citing works
“The strip has a 90 angle between the ribbon part and the insertion part (see details in [8] and [9]).”
BackgroundMethodSelf-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopović, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 405 · see citing works
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · see citing works
Self-citationSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · see citing works
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Self-citationQuantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · see citing works
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123 · see citing works
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · see citing works
Self-citationCiti, L., Carpaneto, J., Yoshida, K., Hoffmann, K., Koch, K., Dario, P., & Micera, S. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.04.025 · Cited by 117 · see citing works
Self-citationPino, G. D., Guglielmelli, E., & Rossini, P. M. (2009) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.03.001 · Cited by 112 · see citing works
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · see citing works
Self-citationMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · see citing works
Self-citationTopographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98 · see citing works
Self-citationRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81 · see citing works
Self-citationUpshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74 · see citing works
Raspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189021 · Cited by 63 · see citing works
Self-citationIntrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Yoshida, K., Jovanović, K., & Stein, R. B. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00176-4 · Cited by 49 · see citing works
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36 · see citing works
Self-citationIn vivo measurement of conduction velocities in afferent and efferent nerve fibre groups in mice
STEFFENS, H., DIBAJ, P., & SCHOMBURG, E. D. (2012) · Physiological Research · doi:10.33549/physiolres.932248 · Cited by 24 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“Selective stimulation and recording have been achieved through TIME at both intra-fascicular and inter-fascicular levels (Badia et al., 2011a, 2016).”
Frost, C. M., Ursu, D. C., Flattery, S. M., Nedic, A., Hassett, C. A., Moon, J. D., Buchanan, P. J., Brent Gillespie, R., Kung, T. A., Kemp, S. W. P., et al. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0452-1 · Cited by 68 · see citing works
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60 · see citing works
“The latter can be classified into two categories: spatial and functional [62].”
BackgroundInfluentialSelf-citationCaravaca, A. S., Tsaava, T., Goldman, L., Silverman, H., Riggott, G., Chavan, S. S., Bouton, C., Tracey, K. J., Desimone, R., Boyden, E. S., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7a42 · Cited by 57 · see citing works
Wang, J., Thow, X. Y., Wang, H., Lee, S., Voges, K., Thakor, N. V., Yen, S., & Lee, C. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700987 · Cited by 43 · see citing works
Vallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35 · see citing works
Self-citationLong-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2897256 · Cited by 26 · see citing works
Self-citationRecording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23 · see citing works
Zhen, G., Chen, H., Tsai, S., Zhang, J., Chen, T., & Jia, X. (2019) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34135 · Cited by 7 · see citing works
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2bb8 · Cited by 7 · see citing works
- Authors
- Badia, J., Raspopovic, S., Carpaneto, J., Micera, S., & Navarro, X.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Biomedical Research Networking Center on Neurodegenerative Diseases (ES)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-01
- Volume
- 24
- Issue
- 1
- Pages
- 20-27
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2248997372
- Semantic Scholar
- 2695bd91a0f9e88dc4fd21c78d133d02cfbecee1
- Cited by
- 65
- References
- 27
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 7 · 2021: 9 · 2020: 7 · 2019: 5 · 2018: 10 · 2017: 12 · 2016: 1 · 2015: 1
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- European Commission
- Italian Ministry of Health (NEMESIS)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- peripheral nerve recording, nerve fascicles, compound nerve action potential, sciatic nerve, neuroprosthetics
- MeSH terms
- Action Potentials, Animals, Diagnostic Techniques, Neurological, Electrodes, Equipment Design, Evoked Potentials, Somatosensory, Sciatic Nerve, Sensitivity and Specificity, Reproducibility of Results, Rats, Sprague-Dawley, Equipment Failure Analysis, Microarray Analysis, Rats, Spatio-Temporal Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review