CoChat

An Implantable Versatile Electrode-Driving ASIC for Chronic Epidural Stimulation in Rats

Open access
Giagka, Vasiliki, Eder, Clemens, Donaldson, Nick, Demosthenous, Andreas · 2015 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 25

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

This paper presents the design and testing of an electrode driving application specific integrated circuit (ASIC) intended for epidural spinal cord electrical stimulation in rats. The ASIC can deliver up to 1 mA fully programmable monophasic or biphasic stimulus current pulses, to 13 electrodes selected in any possible configuration. It also supports interleaved stimulation. Communication is achieved via only 3 wires. The current source and the control of the stimulation timing were kept off-chip to reduce the heat dissipation close to the spinal cord. The ASIC was designed in a 0.18- μm high voltage CMOS process. Its output voltage compliance can be up to 25 V. It features a small core area (<;0.36 mm(2)) and consumes a maximum of 114 μW during a full stimulation cycle. The layout of the ASIC was developed to be suitable for integration on the epidural electrode array, and two different versions were fabricated and electrically tested. Results from both versions were almost indistinguishable. The performance of the system was verified for different loads and stimulation parameters. Its suitability to drive a passive epidural 12-electrode array in saline has also been demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2014.2330859

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 25

Metadata

Authors
Giagka, V., Eder, C., Donaldson, N., & Demosthenous, A.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2015-06
Volume
9
Issue
3
Pages
387-400
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W1987175782
Cited by
25
References
9
FWCI
1.34
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Implantable Versatile Electrode-Driving ASIC for Chronic Epidural Stimulation in Rats. https://app.cochat.ai/papers/10.1109/tbcas.2014.2330859
The paper
Giagka, V., Eder, C., Donaldson, N., & Demosthenous, A. (2015). An Implantable Versatile Electrode-Driving ASIC for Chronic Epidural Stimulation in Rats. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2014.2330859

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.