CoChat

The Microbead: A 0.009 mm3 Implantable Wireless Neural Stimulator

Khalifa, Adam, Liu, Yuxin, Karimi, Yasha, Wang, Qihong, Eisape, Adebayo, Stanacevic, Milutin, Thakor, Nitish, Bao, Zhenan, Etienne-Cummings, Ralph · 2019 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 119

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Wirelessly powered implants are increasingly being developed to interface with neurons in the brain. They often rely on microelectrode arrays, which are limited by their ability to cover large cortical surface areas and long-term stability because of their physical size and rigid configuration. Yet some clinical and research applications prioritize a distributed neural interface over one that offers high channel count. One solution to make large scale, fully specifiable, electrical stimulation/recording possible, is to disconnect the electrodes from the base, so that they can be arbitrarily placed freely in the nervous system. In this work, a wirelessly powered stimulating implant is miniaturized using a novel electrode integration technique, and its implanted depth maximized using new optimization design methods for the transmitter and receiver coils. The stimulating device is implemented in a 130 nm CMOS technology with the following characteristics: 300 μm × 300 μm × 80 μm size; optimized two-coil inductive link; and integrated circuit, electrodes and coil. The wireless and stimulation capability of the implant is demonstrated in a conductive medium, as well as in-vivo. To the best of our knowledge, the fabricated free-floating miniaturized implant has the best depth-to-volume ratio making it an excellent tool for minimally-invasive distributed neural interface, and thus could eventually complement or replace the rigid arrays that are currently the state-of-the-art in brain set-ups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2939014

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A., Stanacevic, M., Thakor, N., Bao, Z., & Etienne-Cummings, R.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2019-10
Volume
13
Issue
5
Pages
971-985
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2972187522
Cited by
119
References
17
FWCI
6.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.