Thin-Film Multiple Electrode Probes: Possibilities and Limitations
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Thin-film multiple electrode probes are produced by means of thin-film techniques. They are successfully employed for potential measurements in brain research. The most advantageous feature of these probes is that the electrodes can be designed and arranged accurately and close together. The geometric size of the electrode areas is usually in the range of between 50 and 10 000 μm2. The size limitations of these thin-film probes are mainly determined by the electrode-electrolyte interface and insulation layer qualities. Since medical research problems, as well as surgical requests, are stressing these limitations, some estimates of maximum resolution and probe dimensions are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Cited by
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
“Devices developed to date have generally been single penetrating silicon needles or comb-like structures with one or more electrodes positioned on the penetrating silicon tines [l], [lo], Ill], [15], [19], [ 20 ].”
BackgroundWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
Multiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173
“Printed circuit electrodes (PCE) (Wise and Starr, 1970; Kuperstein and Eichenbaum, 1985; BeMent et al., 1985; Wise and Drake, 1986; Prohaska and Dragun, 1986; Kewley et al., 1997; Nádasdy et al., 1998) which are made by thin layer microelectronics technologies.”
BackgroundCeramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
Timko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2009.2031807 · Cited by 114
“The ultimate device pitch, which has been demonstrated at the submicron level [58] and could be reduced to as small as tens of nanometers, is much better than has been demonstrated with lithographically defined devices [8]–[ 20 ] or with optical techniques [3].”
BackgroundMethodMacroporous nanowire nanoelectronic scaffolds for synthetic tissues
Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M. (2012) · Nature Materials · doi:10.1038/nmat3404 · Cited by 20
Metadata
- Authors
- Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 223-229
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2076082976
- Cited by
- 103
- References
- 1
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.