CoChat

In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex

Jensen, W., Yoshida, K., Hofmann, U.G. · 2006 · IEEE Transactions on Biomedical Engineering
Cited by 114

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The mechanical behavior of an electrode during implantation into neural tissue can have a profound effect on the neural connections and signaling that takes place within the tissue. The objective of the present work was to investigate the in vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays recently developed by the VSAMUEL consortium (European Union, grant #IST-1999-10073). We have previously reported on both the electrical [1]-[3] and mechanical [4], [5] properties of the ACREO electrodes. In this paper, the tensile and compression forces were measured during a series of in vivo electrode insertions into the cerebral cortex of rats (7 acute experiments, 2-mm implant depth, 2-mm/s insertion velocity). We compared the ACREO silicon electrodes (40 opening angle, 1-8 shafts) to single-shaft tungsten electrodes (3 degrees and 10 degrees opening angles). The penetration force and dimpling increased with the cross-sectional area (statistical difference between the largest and the smallest electrode) and with the number of shafts (no statistical difference). We consistently observed tensile (drag) forces during the retraction phase, which indicates the brain tissue sticks to the electrode within a short time period. Treating the electrodes prior to insertion with silane (hydrophobic) or piranha (hydrophilic) significantly decreased the penetration force. In conclusion, our findings suggest that reusable electrodes for acute animal experiments must not only be strong enough to survive a maximal force that exceeded the penetration force, but must also be able to withstand high tension forces during retraction. Careful cleaning is not only important to avoid foreign body response, but can also reduce the stress applied to the electrode while penetrating the brain tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2006.872824

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Jensen, W., Yoshida, K., & Hofmann, U. G.
Venue
IEEE Transactions on Biomedical Engineering
Published
2006-05
Volume
53
Issue
5
Pages
934-940
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2125920242
Cited by
114
References
5
FWCI
1.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.