An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Important advancements have been recently achieved in the field of neural interfaces to restore lost sensory and motor functions. The aim of this letter was to develop an innovative approach to increase the selectivity and the lifetime of polyimide-based intrafascicular electrodes. The main idea was to obtain a neural interface that is able to restore a good signal quality by improving the electrical connection between the active sites and the surrounding axons. The high flexibility of polyimide-based neural interfaces allows to embed microactuators in the interface core and achieve desired microdisplacements of the active sites. Nearly equiatomic nickel-titanium alloy was selected as a microactuator because of its shape memory effect. A single TiNi thin film was obtained by dc magnetron sputtering, and was segmented into four distinct sectors. This solution allowed the independent actuation of the different active sites (multiactuation). A corrugated profile was impressed to the new actuated intraneural (ACTIN) interface. The active sites were positioned in correspondence to the peaks of the corrugation, thus maximizing the effects of the single actuations. The technological results, the electrical properties, the thermal behavior, and eventually, the actuation performances of the current ACTIN prototype are shown and discussed. The actuation cycle was thermally compatible for biomedical applications. Promising results were obtained from the current ACTIN prototype with an average controlled movement of 7 microm of the peaks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“implanted electrodes is the formation of an encapsulation layer, referred to as gliar scar [4].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1×
“2031169 advanced artificial devices such as robotic arms, visual prostheses, wheelchairs, and PC cursors (see [1]–[3]).”
BackgroundLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 2×
“By observing the cross section of a rat sciatic nerve [9], the interdistance among the fibers is approximately in a range between 1 and 20 μm.”
BackgroundImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202 · cited 1×
“2031169 advanced artificial devices such as robotic arms, visual prostheses, wheelchairs, and PC cursors (see [1]–[3]).”
BackgroundFabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Information contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55 · cited 1×
“, increase in the distance between electrode–target axons and reduction of SNR ratio) [9], [10].”
Background
Cited by
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“The need for devices such as the ACTIN resulted from the degradation of the long-term recording qualities of intrafascicular electrodes as a consequence of the fibrous encapsulation that takes place [66].”
BackgroundMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
“For example, as previously shown for the central nervous system [40], actuation of the active sites of the electrodes [41,42] may help to increase the SNR and selectivity both for stimulation and recording.”
BackgroundSelf-citationWu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3
Metadata
- Authors
- Bossi, S., Kammer, S., DÖrge, T., Menciassi, A., Hoffmann, K. P., & Micera, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 2701-2706
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2109514206
- Cited by
- 27
- References
- 8
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves. https://app.cochat.ai/papers/10.1109/tbme.2009.2031169
- The paper
- Bossi, S., Kammer, S., DÖrge, T., Menciassi, A., Hoffmann, K. P., & Micera, S. (2009). An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2009.2031169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.