Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [18]
Citations
Cites
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038487 · Cited by 693
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Sweat composition in exercise and in heat
Verde, T., Shephard, R. J., Corey, P., & Moore, R. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1540 · Cited by 174
Cited by
Items 201–300 of 423
Beyond liquid biopsy: Toward non-invasive assays for distanced cancer diagnostics in pandemics
Ferrara, F., Zoupanou, S., Primiceri, E., Ali, Z., & Chiriacò, M. S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113698 · Cited by 49
Prakashan, D., Ramya, P. R., & Gandhi, S. (2023) · Diagnostics · doi:10.3390/diagnostics13050916 · Cited by 48
Tian, X., Liu, D., Bai, J., Chan, K. S., Ip, A. L. C., Chan, P. K. L., & Zhang, S. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05210 · Cited by 47
Wearable Ion Sensors for the Detection of Sweat Ions Fabricated by Heat-Transfer Printing
Shitanda, I., Muramatsu, N., Kimura, R., Takahashi, N., Watanabe, K., Matsui, H., Loew, N., Motosuke, M., Mukaimoto, T., Kobayashi, M., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01027 · Cited by 44
Organic electrochromic timer for enzymatic skin patches
Kai, H., Suda, W., Yoshida, S., & Nishizawa, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.013 · Cited by 44
Chen, Y., Lu, S.-Y., & Liao, Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936373 · Cited by 44
Microfluidics for interrogating live intact tissues
Horowitz, L. F., Rodriguez, A. D., Ray, T., & Folch, A. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0164-0 · Cited by 42
Lee, J.-H., Lee, A., Leung, V., Laiwalla, F., López-Gordo, M. A., Larson, L. E., & Nurmikko, A. V. (2024) · Nature Electronics · doi:10.1038/s41928-024-01134-y · Cited by 46
Gao, W. F., Nyein, H. Y. Y., Shahpar, Z., Tai, L., Wu, E. G., Bariya, M., Ota, H., Fahad, H. M., Chen, K., & Javey, A. (2016) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2016.7838363 · Cited by 48
Malon, R. S. P., Heng, L. Y., & Córcoles, E. P. (2017) · Reviews in Analytical Chemistry · doi:10.1515/revac-2016-0018 · Cited by 42
Fiber-Based Sensors and Energy Systems for Wearable Electronics
Lee, J., Jeon, S., Seo, H., Lee, J. T., & Park, S. (2021) · Applied Sciences · doi:10.3390/app11020531 · Cited by 42
All-in-one self-powered wearable biosensors systems
Li, Q., Gao, M., Sun, X., Wang, X., Chu, D., Cheng, W., Xi, Y., & Lu, Y. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100934 · Cited by 42
Printed Organic Transistor-based Biosensors for Non-invasive Sweat Analysis
Nagamine, K., Nomura, A., Ichimura, Y., Izawa, R., Sasaki, S., Furusawa, H., Matsui, H., & Tokito, S. (2020) · Analytical Sciences · doi:10.2116/analsci.19r007 · Cited by 40
Bocu, R. (2024) · Biosensors · doi:10.3390/bios14050214 · Cited by 42
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 38
A Passive UHF RFID Dielectric Sensor for Aqueous Electrolytes
Hillier, A. J. R., Makarovaite, V., Gourlay, C. W., Holder, S. J., & Batchelor, J. C. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2909353 · Cited by 37
The review of Lab‐on‐PCB for biomedical application
Zhao, W., Tian, S., Huang, L., Liu, K., & Dong, L. (2020) · Electrophoresis · doi:10.1002/elps.201900444 · Cited by 38
Recent Advances in Wearable Sensors for the Monitoring of Sweat: A Comprehensive Tendency Summary
Xing, Z., Hui, J., Lin, B., Wu, Z., & Mao, H. (2023) · Chemosensors · doi:10.3390/chemosensors11090470 · Cited by 39
Choi, D.-H., Kitchen, G. B., Stewart, K. J., & Searson, P. C. (2020) · Scientific Reports · doi:10.1038/s41598-020-64406-5 · Cited by 35
A wearable fabric-based RFID skin temperature monitoring patch
Wen, S., Heidari, H., Vilouras, A., & Dahiya, R. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808919 · Cited by 35
Real Time Analysis of Bioanalytes in Healthcare, Food, Zoology and Botany
Wang, T., Ramnarayanan, A., & Cheng, H. (2017) · Sensors · doi:10.3390/s18010005 · Cited by 35
Wearable Label‐Free Optical Biodetectors: Progress and Perspectives
Dhanabalan, S. S., Sriram, S., Walia, S., Avaninathan, S. R., Carrasco, M. F., & Bhaskaran, M. C. (2020) · Advanced Photonics Research · doi:10.1002/adpr.202000076 · Cited by 35
Özer, T., & Henry, C. S. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05264-y · Cited by 34
Steijlen, A. S. M., Jansen, K. M. B., Bastemeijer, J., French, P. J., & Bossche, A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c01052 · Cited by 35
A Dual-Sensing Thermo-Chemical ISFET Array for DNA-Based Diagnostics
Cacho-Soblechero, M., Malpartida-Cardenas, K., Cicatiello, C., Rodríguez-Manzano, J., & Georgiou, P. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2978000 · Cited by 33
Next Steps in Epidermal Computing: Opportunities and Challenges for Soft On-Skin Devices
Nittala, A. S., & Steimle, J. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3517668 · Cited by 37
IonSens: A Wearable Potentiometric Sensor Patch for Monitoring Total Ion Content in Sweat
Hoekstra, R., Blondeau, P., & Andrade, F. J. (2018) · Electroanalysis · doi:10.1002/elan.201800128 · Cited by 33
Park, S. C., Jeong, H. J., Heo, M., Shin, J. H., & Ahn, J. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.1c00152 · Cited by 33
Textile UHF-RFID Antenna Embroidered on Surgical Masks for Future Textile Sensing Applications
Luo, C., Gil, I., & Fernández, R. (2022) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2022.3145477 · Cited by 32
Microwave Devices for Wearable Sensors and IoT
Costanzo, A., Augello, E., Battistini, G., Benassi, F., Masotti, D., & Paolini, G. (2023) · Sensors · doi:10.3390/s23094356 · Cited by 32
Advanced Microfluidic‐Based Wearable Electrochemical Sensors for Continuous Biochemical Monitoring
Park, S., Kim, S., Lee, S.-J., Tsukruk, V. V., Park, S., & Lim, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500010 · Cited by 31
Criscuolo, F., Cantù, F., Taurino, I., Carrara, S., & Micheli, G. D. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009538 · Cited by 31
Wireless Wearable Electrochemical Sensors: A Review
Alves, T., Deroco, P. B., Wachholz, D., Vidotto, L. H. B., & Kubota, L. T. (2021) · Brazilian Journal of Analytical Chemistry · doi:10.30744/brjac.2179-3425.rv-62-2020 · Cited by 32
Applications of deep learning methods in digital biomarker research using noninvasive sensing data
Jeong, H., Jeong, Y. W., Park, Y., Kim, K., Park, J. H., & Kang, D. R. (2022) · Digital Health · doi:10.1177/20552076221136642 · Cited by 36
Soman, V. V., Han, D., Arias, A. C., Ghose, K., Poliks, M. D., Turner, J. N., Khan, Y., Zabran, M., Schadt, M. J., Hart, P., et al. (2019) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2019.2919866 · Cited by 31
Pauliukaitė, R., & Voitechovič, E. (2020) · Sensors · doi:10.3390/s20123551 · Cited by 30
Rajendran, J., & Esfandyarpour, R. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-024-00226-9 · Cited by 34
Mechanics Design of Stretchable Near Field Communication Antenna With Serpentine Wires
Xie, Z., Ji, B., & Huo, Q. (2018) · Journal of Applied Mechanics · doi:10.1115/1.4039102 · Cited by 29
CMOS Interfaces for Internet-of-Wearables Electrochemical Sensors: Trends and Challenges
Dei, M., Aymerich, J., Piotto, M., Bruschi, P., del Campo, F. J., & Serra-Graells, F. (2019) · Electronics · doi:10.3390/electronics8020150 · Cited by 30
Sailapu, S. K., Kraikaew, P., Sabaté, N., & Bakker, E. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01284 · Cited by 28
RETRACTED ARTICLE: Agricultural product monitoring system supported by cloud computing
Jin-bo, C., Xiangliang, C., Fu, H.-C., & Lam, A. (2018) · Cluster Computing · doi:10.1007/s10586-018-2022-5 · Cited by 28
RetractedDry sweat as sample for metabolomics analysis
Delgado‐Povedano, M. D. M., Castillo-Peinado, L. S., Calderón-Santiago, M., de Castro, M. D. L., & Priego‐Capote, F. (2019) · Talanta · doi:10.1016/j.talanta.2019.120428 · Cited by 27
Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat
Lopresti, F., Patella, B., Divita, V., Zanca, C., Botta, L., Radacsi, N., O'Riordan, A. J., Aiello, G., Kersaudy-Kerhoas, M., Inguanta, R., et al. (2022) · Sensors · doi:10.3390/s22218223 · Cited by 25
UHF RFID and NFC Point-of-Care—Architecture, Security, and Implementation
Bianco, G. M., Raso, E., Fiore, L., Mazzaracchio, V., Bracciale, L., Arduini, F., Loreti, P., Marrocco, G., & Occhiuzzi, C. (2023) · IEEE Journal of Radio Frequency Identification · doi:10.1109/jrfid.2023.3268422 · Cited by 25
Wireless Human Motion Detection with a Highly Sensitive Wearable Pressure Sensing Technology
Yan, J., Liu, J., Qu, Q., Chen, X., Liu, J., & Nie, B. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201936 · Cited by 25
Embracing Self-Powered Wearables for Intelligent Healthcare Data Management
Gong, W., Xu, Z., Yuan, L., Zhou, H., Chen, S., Ding, Y., Nayak, A. R., & Liu, J. (2024) · IEEE Internet of Things Journal · doi:10.1109/jiot.2024.3381233 · Cited by 25
Policy Considerations for Mobile Biosensors
Russell, S. M., & de la Rica, R. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00289 · Cited by 25
Jia, Y., Liu, G., Xu, G., Li, X., Shi, Z., Cheng, C., Xu, D., Lu, Y., & Liu, Q. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132050 · Cited by 24
Zhang, H., Qiu, Y., Yu, S., Ding, C., Hu, J., Qi, H., Tian, Y., Zhang, Z., Liu, A., & Wu, H. (2022) · Biomicrofluidics · doi:10.1063/5.0092084 · Cited by 26
Wireless Wearable Devices and Recent Applications in Health Monitoring and Clinical Diagnosis
Su, M., Hua, J., Sun, X., Liu, Z., Shi, Y., & Pan, L. (2023) · Biomedical Materials & Devices · doi:10.1007/s44174-023-00141-5 · Cited by 25
Human Sweat Analysis Using a Portable Device Based on a Screen‐printed Electrolyte Sensor
Hauke, A., Oertel, S., Jank, M. P. M., Frey, L., Langenstein, B., & Bertsch, T. (2017) · Electroanalysis · doi:10.1002/elan.201700672 · Cited by 24
Flexible pH Sensor for Wireless Monitoring of the Human Skin from the Medimun Distances
Nappi, S., Mazzaracchio, V., Fiore, L. D., Arduini, F., & Marrocco, G. (2019) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps.2019.8792291 · Cited by 26
Amirghasemi, F., & Kassegne, S. (2021) · Journal of Electronic Materials · doi:10.1007/s11664-020-08681-y · Cited by 23
New trends in potentiometric sensors: From design to clinical and biomedical applications
Elhassan, M. M., Mahmoud, A. M., Hegazy, M. A. M., Mowaka, S., & Bell, J. G. (2025) · Talanta · doi:10.1016/j.talanta.2025.127623 · Cited by 23
Beyond wearables and implantables: a scoping review of insertable medical devices
Barbone, A. S., Meftah, M., Markiewicz, K., & Dellimore, K. H. J. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4b32 · Cited by 24
Finger-Worn UHF Far-Field RFID Tag Antenna
Taylor, P. S., & Batchelor, J. C. (2019) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2019.2941731 · Cited by 22
Oh, M., Kim, E., Lee, J., Jeong, I., Kim, E., Paek, J., Lee, T., Kim, D., An, S., Kim, S., et al. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202500028 · Cited by 28
Mobile diagnostics: next-generation technologies for in vitro diagnostics
Shin, J., Chakravarty, S., Choi, W., Lee, K., Han, D., Hwang, H., Choi, J., & Jung, H. (2018) · The Analyst · doi:10.1039/c7an01945a · Cited by 21
Wearable biosensors and sample handling strategies
Parlak, O., Curto, V. F., Ojeda, E., Basabe‐Desmonts, L., Benito‐Lopez, F., & Salleo, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00004-7 · Cited by 23
Ultrasensitive Coplanar Dual-Gate ISFETs for Point-of-Care Biomedical Applications
Jeon, J.-H., & Cho, W.-J. (2020) · ACS Omega · doi:10.1021/acsomega.0c00427 · Cited by 21
Kwon, J., Park, H. W., Park, Y.-B., & Kim, N. (2017) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-017-0039-5 · Cited by 21
Clinical translation of biomedical sensors for sports medicine
Seshadri, D. R., Magliato, S. N., Voos, J. E., & Drummond, C. K. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1612474 · Cited by 24
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
Wireless Biological Electronic Sensors
Cui, Y. (2017) · Sensors · doi:10.3390/s17102289 · Cited by 20
Xu, G., Yuan, L., Chen, X., Jia, W., Wang, M., Yang, L., Zhu, J., & Cheng, H. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109721 · Cited by 20
A flexible future for paper-based electronics
Liang, T., Zou, X., & Mazzeo, A. D. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2224391 · Cited by 19
Recent Developments in Microfluidic ‐Based Point‐of‐care Testing ( POCT ) Diagnoses
Wang, D., Chan, H. N., Liu, Z., Micheal, S., Li, L., Dehghan‐Baniani, D., Tan, M. J. A., Huang, L., Wang, J., & Wu, H. (2019) · Wiley eBooks · doi:10.1002/9783527818341.ch8 · Cited by 26
Nanosensors for animal health monitoring
Younis, S., Zia, R., Tahir, N., Bukhari, S. Z., Khan, W. S., & Bajwa, S. Z. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824554-5.00026-4 · Cited by 22
Towards Wearable Electrochemical Lactate Sensing using Osmotic-Capillary Microfluidic Pumping
Yokus, M. A., Saha, T., Fang, J., Dickey, M. D., Velev, O. D., & Daniele, M. A.-A. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956651 · Cited by 20
Bee-based reliable data collection for mobile wireless sensor network
Ren, G. F., Wu, J., & Versonnen, F. (2018) · Cluster Computing · doi:10.1007/s10586-018-2116-0 · Cited by 18
Series-Connected Flexible Biobatteries for Higher Voltage Electrical Skin Patches
Yoshida, S., Mizuno, T., Kusama, S., Sato, K., Raut, B., & Nishizawa, M. (2019) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00671 · Cited by 18
Microfluidics-based devices and their role on point-of-care testing
Kumar, A., & Panda, U. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823424-2.00011-9 · Cited by 21
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 20
Iftekhar, A. T., Ho, J. C.-T., Mellinger, A., & Kaya, T. (2017) · Journal of Applied Physics · doi:10.1063/1.4977998 · Cited by 17
Coplanar Waveguide Based Sensor Using Paper Superstrate for Non-Invasive Sweat Monitoring
Riad, M. M. Y. R., & Eldamak, A. R. (2020) · IEEE Access · doi:10.1109/access.2020.3027033 · Cited by 17
UHF epidermal sensors: Technology and applications
Amendola, S., Occhiuzzi, C., Miozzi, C., Nappi, S., Amato, F., Camera, F., & Marrocco, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00005-x · Cited by 17
Chloride and pH Determination on a Wireless, Flexible Electrochemical Sensor Platform
Søpstad, S., Imenes, K., & Johannessen, E. A. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2944407 · Cited by 17
Rasooly, R., Bruck, H. A., Balsam, J., Prickril, B., Ossandon, M. R., & Rasooly, A. (2016) · Diagnostics · doi:10.3390/diagnostics6020019 · Cited by 16
Long-term cyclic use of a sample collector for toilet-based urine analysis
Temirel, M., Yenilmez, B., & Taşoğlu, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-81842-z · Cited by 16
Flow by design: a guided review of microfluidics for wearable biosensors
Nava-Granados, J., Vasquez, K., Medina, B., Wang, C., Moreto, J. R., & Sempionatto, J. R. (2026) · Lab on a Chip · doi:10.1039/d5lc00628g · Cited by 15
Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
Gray, M. L., Birkenfeld, J., & Butterworth, I. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121028 · Cited by 19
Flexible wearable devices using extrusion-based 3D printing approach: A review
Gupta, A., Kumar, N., & Sachdeva, A. K. (2023) · Materials Today Proceedings · doi:10.1016/j.matpr.2023.07.239 · Cited by 15
Noninvasive Microwave Sensor for Real-Time Continuous Dehydration Monitoring
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3362702 · Cited by 17
Bellando, F., Garcia-Cordero, E., Wildhaber, F., Longo, J., Guérin, H., & Ionescu, A. M. (2017) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2017.8268413 · Cited by 15
Chen, S., Dong, Y., Liu, T., & Li, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113683 · Cited by 15
Transparent Epidermal Antenna for Unobtrusive Human-Centric Internet of Things Applications
Simorangkir, R. B. V. B., Gawade, D. R., Hannon, T., Donovan, P., Kumar, S., Rather, N., Moloudian, G., O’Flynn, B., & Buckley, J. L. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3288994 · Cited by 15
Rasheed, A., Iranmanesh, E., Andrenko, A. S., & Wang, K. (2016) · IEEE International Conference on RFID Technology and Applications (RFID-TA) · doi:10.1109/rfid-ta.2016.7750757 · Cited by 15
Relf, R. L., Eichhorn, G., Waldock, K., Flint, M. S., Beale, L., & Maxwell, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102577 · Cited by 15
Sodium polyacrylate microparticle containing multifunctional skin patch for sweat analysis
Çalamak, S. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105473 · Cited by 14
Yue, X. A., Kiely, J., Luxton, R. W., Chen, B., McLeod, C. N., & Drakakis, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3136705 · Cited by 14
Experimental study of human body effect on temperature sensor integrated RFID tag
Rashee, A., Iranmanesh, E., Li, W., Fen, X., Andrenk, A. S., & Wan, K. (2017) · IEEE International Conference on RFID Technology and Applications (RFID-TA) · doi:10.1109/rfid-ta.2017.8098911 · Cited by 14
Thirsty for a Noninvasive Wearable to Detect Dehydration: A Review
Chiao, J. ‐., Bing, S., Chawang, K., & Crowe, B. (2024) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2024.3442823 · Cited by 13
Ultra-Thin Chips With ISFET Array for Continuous Monitoring of Body Fluids Ph
Baghini, M. S., Vilouras, A., & Dahiya, R. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3141553 · Cited by 13
Microfluidic technologies for local drug delivery
Hassan, S., & Zhang, Y. S. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00010-7 · Cited by 18
Implantable and wearable sensors
Zhang, J. X. J., & Hoshino, K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814862-4.00008-9 · Cited by 17
Vital, D., Bhushan, P., Gaire, P., Islam, M. K., Lahade, S., Pozdin, V. A., Volakis, J. L., Bhansali, S., & Bhardwaj, S. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3294916 · Cited by 12
Choi, D., Kitchen, G. B., Kim, J. S., Li, Y., Kim, K., Jeong, I. C., Nguyen, J., Stewart, K. J., Zeger, S. L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-54202-1 · Cited by 12
Wireless Capacitive Liquid-Level Detection Sensor Based on Zero-Power RFID-Sensing Architecture
Ahmad, S., Khosravi, R., Iyer, A. K., & Mirzavand, R. (2022) · Sensors · doi:10.3390/s23010209 · Cited by 12
Mao, P., Li, H., Shan, X., Davis, M., Tang, T., Zhang, Y., Tong, X., Xin, Y., Cheng, J., Li, L., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04494 · Cited by 12
Totally organic electrical skin patch powered by flexible biobattery
Yoshida, S., Abe, H., Abe, Y., Kusama, S., Tsukada, K., Komatsubara, R., & Nishizawa, M. (2020) · Journal of Physics Energy · doi:10.1088/2515-7655/abb873 · Cited by 15
Metadata
- Authors
- Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C.
- Affiliations
- University of Cincinnati (US)
- Intel (United States) (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-06
- Volume
- 62
- Issue
- 6
- Pages
- 1457-1465
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2167696419
- Cited by
- 416
- References
- 15
- Citations by year
- 2026: 10 · 2025: 18 · 2024: 26 · 2023: 37 · 2022: 34 · 2021: 54 · 2020: 52 · 2019: 62 · 2018: 38 · 2017: 37 · 2016: 36 · 2015: 12
- FWCI
- 14.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Air Force-Air Force Research Labs
- National Science Foundation (#1347725)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable sensors, potentiometric sensing, flexible electronics, polyimide substrate, paper-based microfluidics, skin temperature sensing, hydration monitoring, smartphone data acquisition
- MeSH terms
- Arm, Electrolytes, Equipment Design, Humans, Skin, Sweat, Monitoring, Ambulatory, Radio Frequency Identification Device, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.