Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [18]
Citations
Cites
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038487 · Cited by 693
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Sweat composition in exercise and in heat
Verde, T., Shephard, R. J., Corey, P., & Moore, R. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1540 · Cited by 174
Cited by
Items 401–423 of 423
Advances In Therapeutic Use of Microfluidics (Body on A Chip): A Review
(2023) · International Journal of Nanotechnology and Nanomedicine · doi:10.33140/ijnn.08.01.07
Sweat Electrolyte Detection Patch for Non-invasive Hydration MonitoringPreprint
Rodriguez, J. A., & Díaz-Alonso, D. (2024) · Preprints.org · doi:10.20944/preprints202406.0893.v1
Nanotechnology in Animal and Microenvironment Management
Yadav, A., Kumar, T., Sindhu, N., Kumar, A., Mudgil, N., & Anil Kumar, M. S. (2024) · Livestock diseases and management · doi:10.1007/978-981-16-1610-5_17
Smart wearable sensors for healthcare application
Chu, Z., Zhou, Y., Li, S., Xu, Q., Su, M., & Pan, L. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00030-2
Ferroelectric and FeFET Devices as Biosensors
Bind, U. C., Kumar, K., Bind, V., Kumar, A., & Nishad, J. (2025) · Wiley eBooks · doi:10.1002/9781394287307.ch10
Semi-automatic conformal micro-scale printing with the ultra-precise dispensing (UPD) system
Gramlich, G., Römhild, M., Wendel, J., Weiss, L., Baur, H., Lemmer, U., Fruehauf, N., Zwick, T., & Bhutani, A. (2025) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ae004b
Hapt-Aids: Self-Powered, On-Body Haptics for Activity Monitoring
Shen, V., Yang, X., Harrison, C., & Zhang, Y. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3749468
Yue, X. A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-23903-8.00010-2
Huang, L., Hao, T., Zhang, C., Shi, J., Yao, J., & Xu, J. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.114101
ElectroMeter: The Practical Electrolyte Measurement System
Clapham, J., Zhou, M., MacDonald, C., Koltermann, K., Gao, Y., & Shao, H. (2025) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1145/3721201.3721426
Protein Immobilization on PCB Solder Mask: Toward Low-Cost Biosensing PlatformsPreprint
Pastor-Navarro, N., Hernández-Maciá, M., Pérez-Reinoso, M., Noguera, P., Masot, R., Giménez-Romero, D., & Alcañiz-Fillol, M. (2026) · Preprints.org · doi:10.20944/preprints202601.2369.v1
Laborie, E. (2021) · theses.fr (ABES) · doi:10.70675/b6bfae86zb344z4e7bz8581z483b70c63f21 · Cited by 1
Development of a selective and energy-autonomous lactic acid monitoring system
Lin, S.-H. (2024) · theses.fr (ABES) · doi:10.70675/4cf84d2cz15b0z4e58z8e1fz23980ac846ec
Suzuki, H., & Sassa, F. (2026) · Modern aspects of electrochemistry · doi:10.1007/978-981-95-6483-5_8
Rakhimbekova, A., Rizalputri, L. N., Konstantinidis, A., Shetty, S. S., & Salama, K. N. (2026) · Biosensors · doi:10.3390/bios16050277
Liu, W., Zhang, J., Li, Y., Zhu, X., Guo, W., Lü, X., & Zhang, H. (2026) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2026.111976
Wang, Y., Wen, Y., Wang, X., Sun, H., Feng, H., Ma, Z., Li, Y., Chen, M., Chen, D., Shi, Y., et al. (2026) · Advanced Materials · doi:10.1002/adma.73620
Emerging wearable sweat sensors for monitoring sports health
Wen, H., Huang, F., Gao, Z., Cao, Y., Liu, F., Li, A., Cai, W., Pan, T., & Liu, Q. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118977
Multimodal Wearable Biosensing and Edge AI for Personalized Health: A Comprehensive Review
Wołk, K., Niklewski, J., Tatara, M. S., & Kopczyński, M. (2026) · Electronics · doi:10.3390/electronics15143237
Advancing non-invasive diagnosis through biomarker detection in biofluids
Tang, H., Sun, G., Lu, C., Pouri, H., Panta, R., Chen, T. L., & Zhang, J. (2026) · Nanotechnology · doi:10.1088/1361-6528/ae9d2c
Analytical Approach for Quantifying In-Vivo Sweat Gland Activity Using a Non-Contact Optical Method
Zwicky, J., Aybar, C. G., Fehr, D., Häusler, I. C. R., Lattuada, M., & Bonmarin, M. (2026) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc66907.2026.11694833
Smart Textile Systems as Dynamic Platform for Human Hydration Monitoring
Zou, X., Zhang, Y., Forrester, S., & Xu, L. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00780-4
Low-power wireless communication technologies empower wearable healthcare monitoring
Na, X., Wu, L., Kong, Q., Cao, W., Fang, X., Wu, Y., Bao, T., & Xie, S. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-03256-3
Metadata
- Authors
- Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C.
- Affiliations
- University of Cincinnati (US)
- Intel (United States) (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-06
- Volume
- 62
- Issue
- 6
- Pages
- 1457-1465
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2167696419
- Cited by
- 416
- References
- 15
- Citations by year
- 2026: 10 · 2025: 18 · 2024: 26 · 2023: 37 · 2022: 34 · 2021: 54 · 2020: 52 · 2019: 62 · 2018: 38 · 2017: 37 · 2016: 36 · 2015: 12
- FWCI
- 14.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Air Force-Air Force Research Labs
- National Science Foundation (#1347725)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable sensors, potentiometric sensing, flexible electronics, polyimide substrate, paper-based microfluidics, skin temperature sensing, hydration monitoring, smartphone data acquisition
- MeSH terms
- Arm, Electrolytes, Equipment Design, Humans, Skin, Sweat, Monitoring, Ambulatory, Radio Frequency Identification Device, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.