CoChat

Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes

Rose, Daniel P., Ratterman, Michael E., Griffin, Daniel K., Hou, Linlin, Kelley-Loughnane, Nancy, Naik, Rajesh R., Hagen, Joshua A., Papautsky, Ian, Heikenfeld, Jason C. · 2015 · IEEE Transactions on Biomedical Engineering

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbme.2014.2369991

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

Items 101–200 of 423

Metadata

Authors
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C.
Affiliations
  • University of Cincinnati (US)
  • Intel (United States) (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
2015-06
Volume
62
Issue
6
Pages
1457-1465
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2167696419
Cited by
416
References
15
Citations by year
2026: 10 · 2025: 18 · 2024: 26 · 2023: 37 · 2022: 34 · 2021: 54 · 2020: 52 · 2019: 62 · 2018: 38 · 2017: 37 · 2016: 36 · 2015: 12
FWCI
14.72
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • U.S. Air Force-Air Force Research Labs
  • National Science Foundation (#1347725)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
wearable sensors, potentiometric sensing, flexible electronics, polyimide substrate, paper-based microfluidics, skin temperature sensing, hydration monitoring, smartphone data acquisition
MeSH terms
Arm, Electrolytes, Equipment Design, Humans, Skin, Sweat, Monitoring, Ambulatory, Radio Frequency Identification Device, Mobile Applications

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.