Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Wearable digital health devices are dominantly found in rigid form factors such as bracelets and pucks. An adhesive radio-frequency identification (RFID) sensor bandage (patch) is reported, which can be made completely intimate with human skin, a distinct advantage for chronological monitoring of biomarkers in sweat. In this demonstration, a commercial RFID chip is adapted with minimum components to allow potentiometric sensing of solutes in sweat, and surface temperature, as read by an Android smartphone app with 96% accuracy at 50 mM Na(+) (in vitro tests). All circuitry is solder-reflow integrated on a standard Cu/polyimide flexible-electronic layer including an antenna, but while also allowing electroplating for simple integration of exotic metals for sensing electrodes. Optional paper microfluidics wick sweat from a sweat porous adhesive allowing flow to the sensor, or the sensor can be directly contacted to the skin. The wearability of the patch has been demonstrated for up to seven days, and includes a protective textile which provides a feel and appearance similar to a standard Band-Aid. Applications include hydration monitoring, but the basic capability is extendable to other mM ionic solutes in sweat (Cl(-), K(+), Mg(2+), NH4(+), and Zn(2+)). The design and fabrication of the patch are provided in full detail, as the basic components could be useful in the design of other wearable sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [18]
Citations
Cites
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038487 · Cited by 693
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Sweat composition in exercise and in heat
Verde, T., Shephard, R. J., Corey, P., & Moore, R. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1540 · Cited by 174
Cited by
Items 301–400 of 423
Zhang, H., Wu, Z., Zhi, Z., Gao, W., Sun, W., Hua, Z., & Wu, Y. (2021) · ACS Omega · doi:10.1021/acsomega.1c04229 · Cited by 12
Luo, Q., Ji, W., Yu, Y., Chen, Z., Zhu, J., Li, L., & Chen, G. (2025) · FlexMat. · doi:10.1002/flm2.70011 · Cited by 11
Rana, M. M., Krishnakumar, A., Gopalakrishnan, S., Ramesh, Y., Srinivasan, P., Stanciu, L., & Rahimi, R. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136990 · Cited by 10
Innovations in wearable biosensors: A pathway to 24/7 personalized healthcare
Singh, I., Kumar, S., & Koh, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117938 · Cited by 12
Liu, Q., Yu, Y., Wang, D., & Wang, G. (2021) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2021.3102141 · Cited by 10
Wearable electrochemical sensors for monitoring of inorganic ions and pH in sweat
Zhao, K., Kang, B., & Zhou, B. (2022) · International Journal of Electrochemical Science · doi:10.20964/2022.04.35 · Cited by 10
Thermally Fast-Curable, “Sticky” Nanoadhesive for Strong Adhesion on Arbitrary Substrates
Joo, M., Kwak, M. J., Moon, H., Lee, E., Choi, S. Q., & Im, S. G. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b13298 · Cited by 10
An Artificial Sweating System for Sweat Sensor Testing Applications
Brueck, A., Bates, K. D., Wood, T., House, W., Martinez, Z., Peters, S., Root, B., Yelamarthi, K., & Kaya, T. (2019) · Electronics · doi:10.3390/electronics8060606 · Cited by 10
Programmable Ion-Sensing Using Oscillator-Based ISFET Architectures
Cacho-Soblechero, M., Malpartida-Cardenas, K., Moser, N., & Georgiou, P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2921728 · Cited by 11
Monitoring of biomarkers in sweat with printed sensors combined with sport wearables
Oertel, S., Jank, M. P. M., Schmitz, B., & Lang, N. R. (2016) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2968219.2968574 · Cited by 11
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 12
The Optimization of Analog Front-End for Fully Integrated Wearable Sweat Sensor
Kim, I.-H., Jin, H., Jiang, Y., & Qin, Y. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857939 · Cited by 10
Non-invasive electrochemistry-driven metals tracing in human biofluids
Faheem, A., & Cinti, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113904 · Cited by 9
Smartphone-based medical diagnostics with microfluidic devices
Kim, D. W., Jeong, K. Y., & Yoon, H. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817044-1.00007-7 · Cited by 9
Recent research progress in biomimetic tactile sensors
Zhang, J., Ma, Z., Li, S., Pan, L., & Shi, Y. (2019) · Scientia Sinica Technologica · doi:10.1360/sst-2019-0204 · Cited by 9
A Plug&Play flexible skin sensor for the wireless monitoring of pandemics
Nappi, S., Miozzi, C., Mazzaracchio, V., Fiore, L. D., Camera, F., D'Uva, N., Amendola, S., Occhiuzzi, C., Arduini, F., & Marrocco, G. (2021) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps51544.2021.9469699 · Cited by 9
Rovira, M., Fernández‐Sánchez, C., & Jiménez‐Jorquera, C. (2021) · Biosensors · doi:10.3390/bios11090303 · Cited by 10
Suwalak, R., Phongcharoenpanich, C., & Torrungrueng, D. (2016) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2016.7561481 · Cited by 9
Ultra-Thin Chips with Current-Mode ISFET Array for Continuous Monitoring of Body Fluids pH
Vilouras, A., & Dahiya, R. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401616 · Cited by 8
Peddi, A., & Ramana, T. V. (2022) · International Journal of Nanotechnology · doi:10.1504/ijnt.2022.10046771 · Cited by 8
Zhang, N., Peng, Y., & Guo, Q. (2024) · Digital Health · doi:10.1177/20552076241305233 · Cited by 7
Novel design of a planar flow-through potentiometric sensor
Guagneli, L., Mousavi, Z., Sokalski, T., Leito, I., & Bobacka, J. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116785 · Cited by 7
Karim, A. M. (2024) · Fluids · doi:10.3390/fluids9100223 · Cited by 7
A Lightweight, Zero-Power Intermodulation Sensor Based on the Graphene Oscillator
Yang, M.-Y., Ye, Z.-L., Sun, C.-H., Zhu, L., Hajizadegan, M., & Chen, P.-Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3227891 · Cited by 4
RFID‐based bidirectional wireless rollover sensor for intelligent wheelchair
Liu, Q., Zhao, W., & Yu, Y. (2020) · Microwave and Optical Technology Letters · doi:10.1002/mop.32648 · Cited by 7
A novel type of planar reference electrodes based on ionic liquids
Kuczak, J., Wojcieszek, J., Królikowski, M., Królikowska, M., Dominiczak, J., Krzemiński, J., Budny, F., Wojciechowska, I., Kopytowski, A., Pepłowski, A., et al. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343713 · Cited by 6
Hartnett, W. N., Nguyen, J., Francis, L. F., & Frisbie, C. D. (2024) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ad396f · Cited by 6
Punter-Villagrasa, J., Colomer‐Farrarons, J., del Campo, F. J., & Miribel‐Català, P. L. (2017) · Bioanalysis · doi:10.1007/978-3-319-64801-9_2 · Cited by 7
Development of a small wireless device for perspiration monitoring
Ogai, K., Fukuoka, M., Kitamura, K., Uchide, K., & Nemoto, T. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.12.009 · Cited by 6
Dielectric material determination using the radar equation in RFID sensor applications
Suwalak, R., Phongcharoenpanich, C., Torrungrueng, D., & Akkaraekthalin, P. (2015) · IEEE Conference on Antenna Measurements & Applications · doi:10.1109/cama.2015.7428131 · Cited by 6
Sports medicine: bespoke player management
Stuart, S., Powell, D., Marshall, S. J., Clark, C. C. T., Martini, D. N., Johnston, W., & Godfrey, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00021-1 · Cited by 7
Wearable microfluidic devices for multiplex body fluid monitoring
Sun, Y., Guo, X., Jiang, Y., Cui, J., Wu, J., Wang, J., Cheng, W. M., Shi, Y., & Pan, L. (2025) · The Analyst · doi:10.1039/d5an00739a · Cited by 5
A Frequency Multiplexing Patch Antenna Array for Space Selectable Microwave Heating
Li, C., Lin, X. Q., Yang, X., Wen, Z., & Liang, C. (2022) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2022.3187533 · Cited by 5
Microfluidic temperature sensor based on temperature-dependent dielectric property of liquid*
Liu, Q., Yu, Y.-F., Zhao, W., & Li, H. (2019) · Chinese Physics B · doi:10.1088/1674-1056/ab593c · Cited by 5
Panunzio, N., Occhiuzzi, C., & Marrocco, G. (2021) · IEEE Journal of Radio Frequency Identification · doi:10.1109/jrfid.2021.3060455 · Cited by 5
Jiang, M., Xiao, C., Ding, X., Wang, Y., Zhang, X., Du, Y., Li, X., Zheng, K., Liu, X., Chen, L., et al. (2023) · Science China Technological Sciences · doi:10.1007/s11431-022-2307-6 · Cited by 5
Wearable sweat detector device design for health monitoring and clinical diagnosis
Wu, Q., Zhang, X., Tian, B., Zhang, H., Yu, Y., & Wang, M. (2017) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/69/1/012137 · Cited by 5
Design and Fabrication of Wearable Biosensors: Materials, Methods, and Prospects
Gajjala, R. K. R., Muñana-González, S., Núñez-Marinero, P., Totoricaguena-Gorriño, J., Ruiz‐Rubio, L., & del Campo, F. J. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_15 · Cited by 4
A Review On Wearable Device Technology For Healthcare Industry Applications
Janani, P., & Ruby, E. D. K. (2023) · International Conference on Ambient Intelligence in Health Care (ICAIHC) · doi:10.1109/icaihc59020.2023.10430481 · Cited by 4
Patel, V., Bhatt, S., Daspoddar, A., Shirsekar, V., Kumari, R., Chandra, P., & Srivastava, R. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111165 · Cited by 4
Low-Cost High-Accuracy QRS Detection for Body Area Network Applications
Lin, K.-H., & Wu, J.-H. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0189-x · Cited by 4
A CMOS ISFET array for wearable thermoelectrically powered perspiration analysis
Douthwaite, M., Moser, N., Koutsos, E., Yates, D. C., Mitcheson, P. D., & Georgiou, P. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833723 · Cited by 4
NEEDLE FREE MONITORING OF BLOOD GLUCOSE THROUGH REVERSE IONTOPHORESIS
Chakrabarty, S., BHATTACHARYA, J., Chowdhury, A., Roy, P., & Jha, S. K. (2022) · International Journal of Applied Pharmaceutics · doi:10.22159/ijap.2022v14i4.44288 · Cited by 4
Monajjemi, M., & Mollaamin, F. (2024) · Sensor Review · doi:10.1108/sr-05-2024-0425 · Cited by 4
Towards Wearable Sweat Sensing for Glucose and Lactate: Sensors Characterisation
Dheman, K., Sariglou, A., & Magno, M. (2023) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi58316.2023.10164345 · Cited by 3
Biosensors: Pioneering Progress in Sensing Technologies across Generations
Pakmode, K., Krishnamachary, P., Sultana, T., Pradhan, P. K., Chatterjee, S., & Jana, A. (2023) · International Conference on Sensing Technology · doi:10.1109/icst59744.2023.10460789 · Cited by 3
Wu, Y., Hou, D., Zheng, Y., Lin, X., Yang, F., Liu, C., & Sun, H. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25126393 · Cited by 3
Characterizing Variability in Non-Invasive Hydration Monitoring Using Raman Spectroscopy
Rourke-Funderburg, A. S., Elstub, L. J., Voss, T., Liao, R.-Y., Masson, L. E., & Mahadevan-Jansen, A. M. (2024) · Applied Spectroscopy · doi:10.1177/00037028241307043 · Cited by 3
Embedded passive nano-liter micropump for sweat collection and analysis
Garcia-Cordero, E., Wildhaber, F., Bellando, F., Longo, J., Fernández-Bolaños, M., Guérin, H., & Ionescu, A. M. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346782 · Cited by 3
Bhattacharyya, N. K., Singh, S., Halder, A., Adhikari, A., Ghosh, R., Shikha, D., Tripathi, S. K., Mallick, A. K., Mondal, P., & Pal, S. K. (2021) · Transactions of Indian National Academy of Engineering · doi:10.1007/s41403-021-00204-3 · Cited by 3
Flexible and printed biosensors based on organic TFT devices
Nagamine, K., & Tokito, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815409-0.00020-6 · Cited by 3
Review of developments in sensor technology for monitoring of health-related conditions
Rahman, A., Kafy, A., Kabir, J. F., Pranto, M. T. A., Akther, A., & Choudhury, I. A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00062-5 · Cited by 3
Multimodal Sweat Ion and Sweat Rate Sensing with Inkjet-printed Flexible Bracelet and Paperfluidics
Tonello, S., Golparvar, A. J., Meimandi, A., & Carrara, S. (2023) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea57477.2023.10171913 · Cited by 3
Greene, J. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00014802 · Cited by 5
Dokur, E., Gorduk, O., Gördük, S., & Şahin, Y. (2026) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ae6d39 · Cited by 2
Wearable IoT Devices for Health Monitoring
An, S., Bhat, G., Ogras, U. Y., & Tuncel, Y. (2019) · TechConnect Briefs · Cited by 2
Halder, A., Singh, S., Adhikari, A., Ghosh, S., Shikha, D., Saha, D., Chakraborty, R., Kundu, A. K., Tripathi, S. K., & Pal, S. K. (2019) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c9ja00183b · Cited by 3
Performance evaluations of UHF-RFID flexible antennas fully-integrated with epidermal sensor board
Miozzi, C., Errico, V., Saggio, G., Gruppioni, E., & Marrocco, G. (2020) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps49123.2020.9239578 · Cited by 2
Biosensors and Bioelectronics on Smartphone
Li, S., Ji, D., Xu, G., Liu, J., Lu, Y., Low, S. S., & Liu, Q. (2021) · Springer eBooks · doi:10.1007/978-3-030-23217-7_157 · Cited by 3
Kassanos, P., Gowers, S. A. N., & Boutelle, M. G. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325314 · Cited by 2
Temporary tattoo for wireless human pulse measurement
Pepłowski, A., Janczak, D., Krzemińska, P., & Jakubowska, M. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2248211 · Cited by 2
Human Subjects Testing of Sweat Stimulation Technologies
Wilder, E. (2016) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Ogai, K., Fukuoka, M., Kitamura, K., Uchide, K., & Nemoto, T. (2016) · Journal of Visualized Experiments · doi:10.3791/54837 · Cited by 2
Noroozi, B., & Morshed, B. I. (2019) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2019.8833894 · Cited by 2
SAW Based Passively Bioimpedance Sensing for Zero-Power Wearable Applications of Biosensors
Yue, X. A., Kiely, J., McLeod, C. N., & Wraith, P. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919051 · Cited by 2
Design of flexible curved sensor array for wind pressure monitoring of train bogie
Wang, X., Gao, Y., Deng, F., Xiao, Y., Zhang, H., & Huang, Y. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112873 · Cited by 2
Zheng, J., Xu, X., Hua, Y., Zhao, X., & Xu, W. (2021) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems51815.2021.9451434 · Cited by 2
Lv, F., Zhao, R., Chen, Z., Wang, S., Huang, Y., & Wang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116245 · Cited by 1
Callis, T. W., Joshi, M., & Tentzeris, M. M. (2025) · European Microwave Conference (EuMC) · doi:10.23919/eumc65286.2025.11235194 · Cited by 1
Integration of biochemical sensors into wearable biomaterial platforms
Jandhyala, S., Walper, S. A., Cargill, A. A., Ozual, A., & Daniele, M. A.-A. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2226039 · Cited by 1
Multi-analyte Lab on a Chip Detection Utilizing Optical and Electro-chemical Methods
Ratterman, M. (2015) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Self-citationTatuaże elektroniczne - elastyczne czujniki biomedyczne do monitorowania stanu zdrowia
Pepłowski, A. (2017) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2017.08.36 · Cited by 1
MATTRESS-BASED SWEAT MONITORING FOR HUMAN HEALTH MONITORING AND SMART HOMES
Pavlidis, S., Tsai, M.-Y., Jin, D., Brown, B., Velilla, J.-D., Defranks, M., & Vogel, E. M. (2018) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2018.85 · Cited by 1
Material Processing for Edible Electronics
Xu, W. (2019) · PhDT · Cited by 1
3D Printed Disposable Wireless Ion Selective Sensing Platform
Kim, T., & Kim, W. S. (2019) · IEEE International Flexible Electronics Technology Conference (IFETC) · doi:10.1109/ifetc46817.2019.9073715 · Cited by 1
A handheld device to monitor physiological changes using sweat
Natarajan, G. K., Badhusha, S. M., Monish, R., Rajalakshmi, T., & Umapathy, S. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/912/6/062036 · Cited by 1
Kaul, S., Singh, R. K., Kamaraju, S., & Suman, P. (2020) · Springer eBooks · doi:10.1007/978-981-15-5823-8_8 · Cited by 1
A heat-melt adhesive-assisted transferable electrode films
Maruyama, Y., Nagamine, K., Iwasa, S., Miyabo, A., & Tokito, S. (2021) · Scientific Reports · doi:10.1038/s41598-020-79504-7 · Cited by 1
Coupling‐Independent Sensing Systems with Fully Passive Sensors
Kananian, S., Alexopoulos, G., & Poon, A. S. Y. (2021) · Wiley eBooks · doi:10.1002/9781119683285.ch13 · Cited by 1
Bhattacharyya, N. K., Halder, A., Singh, S., Adhikari, A., Ghosh, R., Mondal, P., & Pal, S. K. (2021) · IEEE International Conference for Convergence in Technology (I2CT) · doi:10.1109/i2ct51068.2021.9417904 · Cited by 1
Design of passive RFID tag using frequency selective surface with polarization insensitive
Azemi, S. N., Ibrahim, N. A., Amir, A., Beson, R. C., & Aziz, M. E. A. (2023) · AIP conference proceedings · doi:10.1063/5.0112208 · Cited by 1
Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring
Naser, M., Nasr, M., & Shehata, L. H. (2023) · International Journal of Progressive Sciences and Technologies · doi:10.52155/ijpsat.v39.1.5361 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Self-citationAdditive Manufacturing of Graphene-Based Devices for Flexible Hybrid Electronics
Pandhi, T. (2020) · ScholarWorks (Boise State University) · doi:10.18122/td/1763/boisestate · Cited by 1
Flexible Amperometric Biosensor for Sweat Lactate Detection
Abrar, A. (2016) · Summit (Simon Fraser University)
WIRELESS SWEAT SIGNAL ANALYSER
Raj, G., & Swetha, R. R. (2016) · Computer Science and Information Technology
Printed sensor systems on flexible substrate
Escobedo, P. (2018) · Institutional Repository of the University of Granada (University of Granada) · doi:10.5281/zenodo.6468174 · Cited by 1
Channel-based Rate Selection for Commodity RFID Networks
Guo, J., Gu, C., Chen, S., Du, H., Wang, X., Yu, J., & Gong, W. (2018) · International Telecommunication Networks and Applications Conference (ITNAC) · doi:10.1109/atnac.2018.8615223
PENCIL DRAWN SENSOR FOR APPLICATION IN SMART BOXES FOR INDUSTRY 4.0
Hackiewicz, K., & Weremczuk, J. (2019) · Industry 4.0
Three-dimensional printing of conductive composite for wireless chemical sensor systems
Kim, T. (2019) · Summit (Simon Fraser University)
Minimally Invasive Technologies for Biosensing
Zhang, S., Lee, K., Goudie, M. J., Kim, H., Sun, W., Lee, J., Chen, Y., Ling, H., Li, Z., Benyshek, C., et al. (2020) · Springer eBooks · doi:10.1007/978-3-030-34467-2_9 · Cited by 2
Biosensors and Bioelectronics on Smartphone
Li, S., Ji, D., Xu, G., Liu, J., Lu, Y., Low, S. S., & Liu, Q. (2020) · Springer eBooks · doi:10.1007/978-3-319-47405-2_157-1
Pumpoung, T., & Eardprab, S. (2020) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecti-con49241.2020.9158317
Status and Future Prospect of Sweat Lactate Monitoring System (Review)
Kudo, H. (2021) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.141.83
Wirelessly Powered Device for Optical Measurement of Respiration Rate
Chen, Y.-C., Tsan, J., & Lin, W. (2021) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea52024.2021.9478773
Smartphone-based chemical sensors and biosensors for biomedical applications
Li, X., Cheng, C., Shi, Z., Liu, G., Yan, Z., Chen, Z., Lu, Y., & Liu, Q. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823727-4.00015-8
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2019) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-030-13765-6_2 · Cited by 1
Low-power Wearable Healthcare Sensors
Sherratt, R. S., & Dey, N. (2020) · MDPI eBooks · doi:10.3390/books978-3-03936-480-0
Correlating the Effect of Dynamic Variability in the Sensor Environment on Sensor Design
Bhushan, P. (2021) · FIU - Digital Commons (Florida International University) · doi:10.25148/etd.fidc009698 · Cited by 1
Metadata
- Authors
- Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C.
- Affiliations
- University of Cincinnati (US)
- Intel (United States) (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-06
- Volume
- 62
- Issue
- 6
- Pages
- 1457-1465
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2167696419
- Cited by
- 416
- References
- 15
- Citations by year
- 2026: 10 · 2025: 18 · 2024: 26 · 2023: 37 · 2022: 34 · 2021: 54 · 2020: 52 · 2019: 62 · 2018: 38 · 2017: 37 · 2016: 36 · 2015: 12
- FWCI
- 14.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Air Force-Air Force Research Labs
- National Science Foundation (#1347725)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable sensors, potentiometric sensing, flexible electronics, polyimide substrate, paper-based microfluidics, skin temperature sensing, hydration monitoring, smartphone data acquisition
- MeSH terms
- Arm, Electrolytes, Equipment Design, Humans, Skin, Sweat, Monitoring, Ambulatory, Radio Frequency Identification Device, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.