The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Open accessAbstract
Continuum robots provide inherent structural compliance with high dexterity to access the surgical target sites along tortuous anatomical paths under constrained environments and enable to perform complex and delicate operations through small incisions in minimally invasive surgery. These advantages enable their broad applications with minimal trauma and make challenging clinical procedures possible with miniaturized instrumentation and high curvilinear access capabilities. However, their inherent deformable designs make it difficult to realize 3-D intraoperative real-time shape sensing to accurately model their shape. Solutions to this limitation can lead themselves to further develop closely associated techniques of closed-loop control, path planning, human-robot interaction, and surgical manipulation safety concerns in minimally invasive surgery. Although extensive model-based research that relies on kinematics and mechanics has been performed, accurate shape sensing of continuum robots remains challenging, particularly in cases of unknown and dynamic payloads. This survey investigates the recent advances in alternative emerging techniques for 3-D shape sensing in this field and focuses on the following categories: fiber-optic-sensor-based, electromagnetic-tracking-based, and intraoperative imaging modality-based shape-reconstruction methods. The limitations of existing technologies and prospects of new technologies are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber Bragg grating technology fundamentals and overview
Hill, K. O., & Meltz, G. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618320 · Cited by 3,060
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Review of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Kinematics for multisection continuum robots
Jones, B. A., & Walker, I. D. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2005.861458 · Cited by 955
Statics and Dynamics of Continuum Robots With General Tendon Routing and External Loading
Rucker, D. C., & Webster III, R. J. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2160469 · Cited by 669
Mechanics Modeling of Tendon-Driven Continuum Manipulators
Camarillo, D. B., Milne, C. F., Carlson, C. R., Zinn, M. R., & Salisbury, J. K. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2002311 · Cited by 655
Continuum robots - a state of the art
Robinson, G., & Davies, J. B. C. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.774029 · Cited by 619
Minimally Invasive and Robotic Surgery
Mack, M. J. (2001) · JAMA · doi:10.1001/jama.285.5.568 · Cited by 545
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321777 · Cited by 504
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Emerging Robotic Platforms for Minimally Invasive Surgery
Vitiello, V., Lee, S.-L., Cundy, T. P., & Yang, G.-Z. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2236311 · Cited by 457
Geometrically Exact Models for Soft Robotic Manipulators
Trivedi, D., Lotfi, A., & Rahn, C. D. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.924923 · Cited by 428
Continuous Backbone “Continuum” Robot Manipulators
Walker, I. D. (2013) · ISRN Robotics · doi:10.5402/2013/726506 · Cited by 405
Evolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321
Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
Maier-Hein, L., Mountney, P., Bartoli, A., Elhawary, H., Elson, D., Groch, A., Kolb, A., Rodrigues, M., Sorger, J., Speidel, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.04.003 · Cited by 280
Xu, K., & Simaan, N. (2010) · Journal of Mechanisms and Robotics · doi:10.1115/1.4000519 · Cited by 279
Fiber grating sensors in medicine: Current and emerging applications
Mishra, V., Singh, N., Tiwari, U., & Kapur, P. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.045 · Cited by 275
Curvature, Torsion, and Force Sensing in Continuum Robots Using Helically Wrapped FBG Sensors
Xu, R., Yurkewich, A., & Patel, R. V. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2530867 · Cited by 268
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2080360 · Cited by 266
Practical Kinematics for Real-Time Implementation of Continuum Robots
Jones, B. A., & Walker, I. D. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886268 · Cited by 240
A review of medical robotics for minimally invasive soft tissue surgery
Dogangil, G., Davies, B. L., & Rodriguez y Baena, F. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim591 · Cited by 225
Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview
Taffoni, F., Formica, D., Saccomandi, P., Pino, G., & Schena, E. (2013) · Sensors · doi:10.3390/s131014105 · Cited by 221
From Passive Tool Holders to Microsurgeons: Safer, Smaller, Smarter Surgical Robots
Bergeles, C., & Yang, G.-Z. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2293815 · Cited by 215
Real-Time Stereo Reconstruction in Robotically Assisted Minimally Invasive Surgery
Stoyanov, D., Scarzanella, M. V., Pratt, P., & Yang, G.-Z. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15705-9_34 · Cited by 211
Concentric Tube Robots: The State of the Art and Future Directions
Gilbert, H. B., Rucker, D. C., & Webster III, R. J. (2016) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-28872-7_15 · Cited by 197
He, X., Handa, J., Gehlbach, P., Taylor, R., & Iordachita, I. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283501 · Cited by 191
Three-Dimensional Tissue Deformation Recovery and Tracking
Mountney, P., Stoyanov, D., & Yang, G.-Z. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936728 · Cited by 188
Huang, J., Huo, W., Xu, W., Mohammed, S., & Amirat, Y. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2015.2466634 · Cited by 185
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
Soft-Tissue Motion Tracking and Structure Estimation for Robotic Assisted MIS Procedures
Stoyanov, D. V., Mylonas, G. P., Deligianni, F., Darzi, A. W., & Yang, G. Z. (2005) · Lecture notes in computer science · doi:10.1007/11566489_18 · Cited by 161
FBG-based shape sensing tubes for continuum robots
Ryu, S. C., & Dupont, P. E. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907368 · Cited by 159
Macrobend optical sensing for pose measurement in soft robot arms
Sareh, S., Noh, Y., Li, M., Ranzani, T., Liu, H., & Althoefer, K. A. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/12/125024 · Cited by 154
Three‐dimensional ultrasound‐guided robotic needle placement: an experimental evaluation
Boctor, E. M., Choti, M. A., Burdette, E. C., & Webster, R. J., III (2008) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.184 · Cited by 151
Abushagur, A. A. G., Arsad, N., Reaz, M. B. I., & Bakar, A. A. A. (2014) · Sensors · doi:10.3390/s140406633 · Cited by 143
Vision-based Navigation in Image-Guided Interventions
Mirota, D. J., Ishii, M., & Hager, G. D. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124757 · Cited by 137
Dziuda, Ł., Skibniewski, F. W., Krej, M., & Baran, P. M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.057006 · Cited by 122
Song, S., Li, Z., Meng, M. Q. ‐., et al. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2456181 · Cited by 110
Self-citationBergen, T., & Wittenberg, T. C. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2384134 · Cited by 106
Payne, C. J., & Yang, G. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1042-4 · Cited by 106
A Novel Continuum Manipulator Design Using Serially Connected Double-Layer Planar Springs
Qi, P., Qiu, C., Liu, H., Dai, J. S., Seneviratne, L. D., & Althoefer, K. A. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2498738 · Cited by 105
Self-citationError Analysis of FBG-Based Shape Sensors for Medical Needle Tracking
Henken, K. R., Dankelman, J., van den Dobbelsteen, J. J., Cheng, L. K., & van der Heiden, M. S. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2287764 · Cited by 91
Lin, B., Sun, Y., Qian, X., Goldgof, D. B., Gitlin, R. D., & You, Y. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1661 · Cited by 83
Shape Tracking of a Dexterous Continuum Manipulator Utilizing Two Large Deflection Shape Sensors
Liu, H., Farvardin, A., Grupp, R. B., Murphy, R. J., Taylor, R. H., Iordachita, I. I., & Armand, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2442266 · Cited by 82
Application of robotics in gastrointestinal endoscopy: A review
Yeung, B. P. M. (2016) · World Journal of Gastroenterology · doi:10.3748/wjg.v22.i5.1811 · Cited by 82
Real-time shape estimation for continuum robots using vision
Hannan, M. W., & Walker, I. D. (2005) · Robotica · doi:10.1017/s0263574704001018 · Cited by 80
Optimizing curvature sensor placement for fast, accurate shape sensing of continuum robots
Kim, B., Ha, J., Park, F. C., & Dupont, P. E. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907649 · Cited by 78
Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging
Stoll, J. A., Ren, H., & Dupont, P. E. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2173586 · Cited by 76
Self-citationReal-time three-dimensional flexible needle tracking using two-dimensional ultrasound
Vrooijink, G. J., Abayazid, M., & Misra, S. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630797 · Cited by 76
Development of a compact continuum tubular robotic system for nasopharyngeal biopsy
Wu, L., Song, S., Wu, K., Lim, C. M., & Ren, H. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1514-9 · Cited by 76
Self-citationAn optical curvature sensor for flexible manipulators
Searle, T., Althoefer, K. A., Seneviratne, L. D., & Liu, H. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631203 · Cited by 61
Large deflection shape sensing of a continuum manipulator for minimally-invasive surgery
Liu, H., Farvardin, A., Pedram, S. A., Iordachita, I. I., Taylor, R. H., & Armand, M. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139000 · Cited by 56
3D curve reconstruction by biplane snakes
Cañero, C., Radeva, P. I., Toledo, R., Villanueva, J. J., & Mauri, J. (2002) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2000.902982 · Cited by 53
Development and comparison of new hybrid motion tracking for bronchoscopic navigation
Luó, X., Marco Feuerstein, A., Deguchi, D., Kitasaka, T., Takabatake, H., & Mori, K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.11.001 · Cited by 51
Simultaneous Electromagnetic Tracking and Calibration for Dynamic Field Distortion Compensation
Sadjadi, H., Hashtrudi-Zaad, K., & Gabor Fichtinger, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2502138 · Cited by 51
Simultaneous catheter and environment modeling for Trans-catheter Aortic Valve Implantation
Shi, C., Giannarou, S., Su-Lin, L., & Yang, G. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6942832 · Cited by 49
Self-citation4D interventional device reconstruction from biplane fluoroscopy
Wagner, M., Schafer, S., Strother, C., & Mistretta, C. (2016) · Medical Physics · doi:10.1118/1.4941950 · Cited by 48
Chang, P.-L., Stoyanov, D. V., Davison, A. J., & Edwards, P. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_6 · Cited by 47
Shape estimation for image-guided surgery with a highly articulated snake robot
Tully, S., Kantor, G. A., Zenati, M. A., & Choset, H. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094751 · Cited by 47
Wu, X., Housden, R. J., Ma, Y., Razavi, B., Rhode, K., & Rueckert, D. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2360988 · Cited by 44
Posture estimation and human support using wearable sensors and walking-aid robot
Huang, J., Xu, W., Mohammed, S., & Shu, Z. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.11.013 · Cited by 41
Linte, C. A., White, J. A., Eagleson, R. A., Guiraudon, G. M., & Peters, T. M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2082522 · Cited by 41
Fusion of Electromagnetic Trackers to Improve Needle Deflection Estimation: Simulation Study
Sadjadi, H., Hashtrudi-Zaad, K., & Gabor Fichtinger, A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2262658 · Cited by 40
US–Fluoroscopy Registration for Transcatheter Aortic Valve Implantation
Lang, P., Seslija, P., Chu, M. W. A., Bainbridge, D., Guiraudon, G. M., Jones, D. L., & Peters, T. M. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2189392 · Cited by 40
Robot‐assisted minimally invasive lung brachytherapy
Trejos, A. L., Lin, A. W., Pytel, M., Patel, R. V., & Malthaner, R. A. (2007) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.126 · Cited by 39
Electrophysiology Catheter Detection and Reconstruction From Two Views in Fluoroscopic Images
Hoffmann, M., Brost, A., Koch, M., Bourier, F. J., Maier, A., Kurzidim, K. W., Strobel, N. K., & Joachim Hornegger, A. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2482539 · Cited by 39
Optical-Fiber Measurement Systems for Medical Applications
Silvestri, S., & Sche, E. (2011) · InTech eBooks · doi:10.5772/18845 · Cited by 38
Mahoney, A. W., Bruns, T. L., Swaney, P. J., & Webster, R. J., III (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487646 · Cited by 38
Semi-automatic Catheter Reconstruction from Two Views
Hoffmann, M., Brost, A., Jakob, C., Bourier, F. J., Koch, M., Kurzidim, K. W., Joachim Hornegger, A., & Strobel, N. K. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33418-4_72 · Cited by 35
Simultaneous localization and calibration for electromagnetic tracking systems
Sadjadi, H., Hashtrudi-Zaad, K., & Gabor Fichtinger, A. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1670 · Cited by 32
Autonomous Real-Time Interventional Scan Plane Control With a 3-D Shape-Sensing Needle
Elayaperumal, S., Plata, J., Holbrook, A. B., Park, Y., Butts, K., Daniel, B. L., & Cutkosky, M. R. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2332354 · Cited by 28
Shi, C., Tercero, C. R., Ikeda, S., Ooe, K., Fukuda, T., Komori, K., & Yamamoto, K. (2012) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1416 · Cited by 27
Self-citationReconstruction method for curvilinear structures from two views
Hoffmann, M., Brost, A., Jakob, C., Koch, M., Bourier, F. J., Kurzidim, K. W., Joachim Hornegger, A., & Strobel, N. K. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2006346 · Cited by 27
A Filtering Approach for Image-Guided Surgery With a Highly Articulated Surgical Snake Robot
Tully, S., & Choset, H. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2461531 · Cited by 26
Otake, Y., Murphy, R. J., Kutzer, M. D. M., Taylor, R. H., & Armand, M. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043242 · Cited by 25
Real‐timein vitrointravascular reconstruction and navigation for endovascular aortic stent grafting
Shi, C., Tercero, C. R., Wu, X., Ikeda, S., Komori, K., Yamamoto, K., Arai, F., & Fukuda, T. (2016) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1736 · Cited by 24
Self-citationLuó, X., Wan, Y., He, X., et al. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.01.002 · Cited by 22
Snake robot shape sensing using micro-inertial sensors
Zhang, Z., Shang, J., Seneci, C., & Yang, G. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696447 · Cited by 21
Multi-camera based real-time configuration estimation of continuum robots
Weber, B., Zeller, P., & Kühnlenz, K. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6385944 · Cited by 14
Luó, X., McLeod, A. J., Jayarathne, U. L., et al. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216969 · Cited by 4
Luó, X., Jayarathne, U. L., Pautler, S. E., et al. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-21978-3_58 · Cited by 4
Cited by
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Shi, C., Zhang, H., Ni, X., & Wang, K. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3311052 · Cited by 33
Self-citation
Metadata
- Authors
- Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-08
- Volume
- 64
- Issue
- 8
- Pages
- 1665-1678
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2544641369
- Cited by
- 420
- References
- 82
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.