CoChat

Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics

Liu, Jing, Yan, Bryan P., Zhang, Yuan-Ting, Ding, Xiao-Rong, Su, Peng, Zhao, Ni · 2019 · IEEE Transactions on Biomedical Engineering
Cited by 139

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To fight the "silent killer" hypertension, continuous blood pressure (BP) monitoring has been one of the most desired functions in wearable electronics. However, current BP measuring principles and protocols either involve a vessel occlusion process with a cuff or require multiple sensing nodes on the body, which makes it difficult to implement them in compact wearable electronics like smartwatches and wristbands with long-term wearability. METHODS: In this work, we proposed a highly compact multi-wavelength photoplethysmography (MWPPG) module and a depth-resolved MWPPG approach for continuous monitoring of BP and systemic vascular resistance (SVR). By associating the wavelength-dependent light penetration depth in the skin with skin vasculatures, our method exploited the pulse transit time (PTT) on skin arterioles for tracking SVR (n = 20). Then, we developed an arteriolar PTT-based method for beat-to-beat BP measurement. The BP estimation accuracy of the proposed arteriolar PTT method was validated against Finometer (n = 20) and the arterial line (n = 4). RESULTS: The correlation between arteriolar PTT and SVR was theoretically deduced and experimentally validated on 20 human subjects performing various maneuvers. The proposed arteriolar PTT-based method outperformed the traditional arterial PTT-based method with better BP estimation accuracy and simpler measurement setup, i.e., with a single sensing node. CONCLUSION: The proposed depth-resolved MWPPG method can provide accurate measurements of SVR and BP, which are traditionally difficult to measure in a noninvasive or continuous fashion. SIGNIFICANCE: This MWPPG work provides the wearable healthcare electronics of compact size with a low-cost and physiology-based solution for continuous measurement of BP and SVR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2018.2874957

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Liu, J., Yan, B. P., Zhang, Y.-T., Ding, X.-R., Su, P., & Zhao, N.
Venue
IEEE Transactions on Biomedical Engineering
Published
2019-06
Volume
66
Issue
6
Pages
1514-1525
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2896436581
Cited by
139
References
11
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.