Dysphagia Screening: Contributions of Cervical Auscultation Signals and Modern Signal-Processing Techniques
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Cervical auscultation is the recording of sounds and vibrations caused by the human body from the throat during swallowing. While traditionally done by a trained clinician with a stethoscope, much work has been put towards developing more sensitive and clinically useful methods to characterize the data obtained with this technique. The eventual goal of the field is to improve the effectiveness of screening algorithms designed to predict the risk that swallowing disorders pose to individual patients' health and safety. This paper provides an overview of these signal processing techniques and summarizes recent advances made with digital transducers in hopes of organizing the highly varied research on cervical auscultation. It investigates where on the body these transducers are placed in order to record a signal as well as the collection of analog and digital filtering techniques used to further improve the signal quality. It also presents the wide array of methods and features used to characterize these signals, ranging from simply counting the number of swallows that occur over a period of time to calculating various descriptive features in the time, frequency, and phase space domains. Finally, this paper presents the algorithms that have been used to classify this data into 'normal' and 'abnormal' categories. Both linear as well as non-linear techniques are presented in this regard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complications and Outcome After Acute Stroke: Does Dysphagia Matter?
Smithard, D. G., O'Neill, P. A., Park, C., Morris, J., Wyatt, R., England, R., & Martin, D. F. (1996) · Stroke · doi:10.1161/01.str.27.7.1200 · Cited by 734
Methodology for detecting swallowing sounds
Takahashi, K., Groher, M., & Michi, K.-I. (1994) · Dysphagia · doi:10.1007/bf00262760 · Cited by 215 · cited 10×
“The figure has been reproduced from the original work [16] with kind permission of Springer Science+Business Media.”
InfluentialDetection of Swallowing Sounds: Methodology Revisited
Cichero, J. A. Y., & Murdoch, B. E. (2002) · Dysphagia · doi:10.1007/s00455-001-0100-x · Cited by 97
Origin of the Sound Components During Pharyngeal Swallowing in Normal Subjects
Morinière, S., Boiron, M., Alison, D., Makris, P., & Beutter, P. (2008) · Dysphagia · doi:10.1007/s00455-007-9134-z · Cited by 88 · cited 6×
“Diagram depicting links between cervical auscultation and the underlying physiology that is used by some clinicians in bedside analysis [48].”
InfluentialStethoscope acoustics and cervical auscultation of swallowing
Hamlet, S., Penney, D., & Formolo, J. (1994) · Dysphagia · doi:10.1007/bf00262761 · Cited by 79 · cited 7×
“noise at either end of the frequency spectrum [13], [28], [38], [39], [43]–[47], [49], [51], [53]–[62], [65], [68]–[73], [84]–[89].”
InfluentialSejdic, E., Steele, C. M., & Chau, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010504 · Cited by 73 · cited 5×
“maintain a “pure” signal [21], [49], [51], [65], [66], [83], [86], [90], others place it as high as 30 Hz or more in order to eliminate motion artifacts and other low-frequency noise [39], [42], [44],”
InfluentialA comparative analysis of swallowing accelerometry and sounds during saliva swallows
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-3 · Cited by 72
Self-citationEffects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
Lee, J., Sejdić, E., Steele, C. M., & Chau, T. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-7 · Cited by 68
Self-citationAn Online Swallow Detection Algorithm Based on the Quadratic Variation of Dual-Axis Accelerometry
Damouras, S., Sejdic, E., Steele, C. M., & Chau, T. (2010) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2010.2043972 · Cited by 43
Swallow segmentation with artificial neural networks and multi-sensor fusion
Lee, J., Steele, C. M., & Chau, T. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.07.001 · Cited by 40 · cited 5×
“2006–2010 [30], [47], [65]–[67] [28], [46], [47], [49], [65], [68]–[73] [65], [66] [74], [75] [65], [71], [76]–[79] [71], [76] [80]–[83]”
Influential
Research works printed but not linked: 115
- 10.1007/s11517-012-0938-0 · DOI
- 10.4108/icst.pervasivehealth.2011.246029 · DOI
- 10.1007/BF00341260 · DOI
- 10.1007/BF02407270 · DOI
- 10.1109/IEMBS.2007.4353003 · DOI
- 10.1109/IEMBS.2006.259353 · DOI
- 10.1007/s00455-007-9099-y · DOI
- 10.1007/s004150070091 · DOI
- 10.1007/BF02412637 · DOI
- 10.1007/PL00009594 · DOI · Paper page
- 10.1007/s00455-007-9084-5 · DOI
- 10.1007/s00455-007-9078-3 · DOI
- 10.1590/S0104-56872008000400005 · doi:10.1590/s0104-56872008000400005
- 10.1007/s00455-008-9160-5 · DOI
- 10.1007/PL00009583 · DOI · Paper page
- 10.1161/STROKEAHA.107.510370 · DOI · Paper page
- 10.1007/s11605-009-0937-0 · DOI
- hey, 2013, Water swallow screening test for patients after surgery for head and neck cancer: Early identification of dysphagia, aspiration, and limitations of oral intake, Anticancer Res, 33, 4017
- 10.1111/jtxs.12009 · DOI
- 10.1161/01.STR.0000177529.86868.8d · DOI · Paper page
- reddy, 1994, Toward classification of dysphagic patients using biomechanical measurements, J Rehabil Res Develop, 31, 335
- 10.1109/IEMBS.1999.804066 · doi:10.1109/iembs.1999.804066
- 10.1016/S1350-4533(00)00047-3 · DOI · Paper page
- preiksaitis, 1996, Coordination of breathing and swallowing: Effects of bolus consistency and presentation in normal adults, J Appl Physiol, 81, 1707, 10.1152/jappl.1996.81.4.1707 · DOI
- 10.1109/IMTC.2000.846852 · doi:10.1109/imtc.2000.846852
- 10.1007/BF00265212 · doi:10.1007/bf00265212
- 10.1109/IEMBS.1994.415438 · doi:10.1109/iembs.1994.415438
- 10.1109/IEMBS.1994.415345 · DOI
- 10.1109/51.7929 · DOI
- 10.1088/0967-3334/29/5/001 · DOI · Paper page
- 10.1016/S0016-5085(99)70144-7 · DOI · Paper page
- 10.1111/j.1365-2648.2008.04915.x · DOI · Paper page
- 10.1007/s00455-007-9084-5 · DOI
- 10.1016/S0924-980X(98)00027-7 · DOI
- 10.1007/s10439-009-9874-z · DOI
- 10.1007/PL00009597 · DOI
- 10.1002/hbm.20743 · DOI · Paper page
- 10.2340/16501977-0384 · DOI
- 10.1007/BF00341261 · DOI
- 10.1088/0967-3334/31/6/008 · DOI · Paper page
- 10.1016/j.chaos.2006.09.026 · DOI
- firmin, 1997, Non-invasive monitoring of reflexive swallowing, Speech Language and Hearing Research, 10, 171
- 10.1007/s11517-012-0958-9 · DOI
- 10.1109/IEMBS.2004.1404070 · DOI
- 10.1212/01.WNL.0000046586.38284.60 · DOI · Paper page
- 10.1016/j.otohns.2008.11.016 · DOI
- 10.1053/apmr.2000.6301 · DOI · Paper page
- 10.1111/j.1365-2648.2008.04915.x · DOI · Paper page
- guo, 2010, Chaotic feature of water swallowing sound signals revealed by correlation dimension, Proc 2nd Int Conf Inf Sci Eng, 1, 171
- 10.1109/IEMBS.2010.5627509 · DOI
- 10.1109/IEMBS.2007.4352992 · DOI
- makeyev, 2009, Recognition of Swallowing Sounds Using Time-Frequency Decomposition and Limited Receptive Area Neural Classifier, 15
- 10.1016/j.compbiomed.2010.09.002 · DOI
- 10.1016/j.medengphy.2010.04.008 · DOI
- 10.1109/IJCNN.2007.4371197 · DOI
- 10.1155/2010/323125 · DOI
- 10.1016/S0169-2607(00)00099-7 · DOI
- 10.1109/IEMBS.2004.1404068 · DOI
- 10.1109/TBME.2004.836504 · DOI · Paper page
- lazareck, 2004, Classification of Swallowing Sound Signals A Rough Set Approach, 3066
- 10.1109/IEMBS.2005.1616114 · DOI
- 10.1088/0967-3334/29/9/008 · DOI · Paper page
- 10.1088/0967-3334/31/1/N01 · DOI · Paper page
- 10.1016/j.compeleceng.2007.12.001 · DOI
- 10.1271/bbb.60276 · DOI
- castrogiovanni, 2008, Communication facts Special population Dysphagia
- eylgor, 2007, Effects of age, gender, bolus volume and viscosity on acoustic signals of normal swallowing, J Phys Med Rehabil, 53, 94
- spieker, 2000, Evaluating dysphagia, Amer Family Physician, 61, 3639
- 10.1109/IEMBS.1992.5761904 · DOI
- 10.1111/j.1365-2842.2012.02293.x · DOI
- 10.1121/1.2026792 · doi:10.1121/1.2026792
- 10.1007/s00455-010-9323-z · DOI
- 10.1007/s00455-012-9416-y · DOI
- 10.1111/j.1469-8749.2003.tb00938.x · DOI
- 10.1007/BF02493450 · DOI
- stroud, 2002, Inter- and intra-rater reliability of cervical auscultation to detect aspiration in patients with dysphagia, Clinical Rehabilitation, 16, 640, 10.1191/0269215502cr533oa · DOI · Paper page
- 10.1016/0141-5425(91)90018-3 · DOI · Paper page
- 10.1007/BF02638588 · doi:10.1007/bf02638588
- afkari, 2007, Measuring frequency of spontaneous swallowing, Australasian College Phys Sci Eng Med, 30, 313
- 10.1371/journal.pone.0033464 · DOI · Paper page
- 10.1007/s00455-010-9322-0 · DOI
- 10.1111/joor.12085 · doi:10.1111/joor.12085
- 10.1016/S0020-7101(05)80002-9 · DOI
- 10.1121/1.4750491 · DOI
- 10.1590/S2179-64912012000300006 · DOI
- 10.1109/TBME.2009.2033037 · DOI · Paper page
- 10.1016/j.bspc.2012.03.005 · DOI
- sarraf-shirazi, 2012, Silent aspiration detection by breath and swallowing sound analysis, Proc 34th Annu Int Conf IEEE Eng Med Biol Soc, 1, 2599
- 10.1109/IEMBS.2011.6091292 · doi:10.1109/iembs.2011.6091292
- bosma, 1957, Deglutition: Pharyngeal stage, Physiol Rev, 37, 275, 10.1152/physrev.1957.37.3.275 · DOI · Paper page
- goyal, 2006, Physiology of oral, pharyngeal, and esophageal motility, GI Motility Online, 1, 1
- 2003, Full Revision of the International Standards for Equal-Loudness Level Contours
- 10.1007/BF00261276 · DOI · Paper page
- 10.1111/j.1469-8749.2002.tb00843.x · doi:10.1111/j.1469-8749.2002.tb00843.x
- talkin, 1995, A robust algorithm for pitch tracking (RAPT), Speech Coding and Synthesis, 495
- 10.1016/j.chaos.2007.01.071 · DOI
- 10.2307/2337118 · DOI
- 10.1007/s00455-005-0013-1 · DOI
- 10.1007/s11517-007-0285-8 · DOI
- 10.1016/j.artmed.2011.03.002 · DOI
- 10.1109/IEMBS.2002.1134449 · DOI
- 10.1177/000348949009900916 · DOI · Paper page
- 10.1177/000348940811700403 · DOI
- 10.1007/s00455-006-9023-x · DOI
- sarraf-shirazi, 2011, Investigating the statistical properties of the swallowing sounds, Proc 33rd Annu Int Conf IEEE Eng Med Biol Soc, 1, 6021
- 10.1109/IEMBS.2006.259354 · DOI
- 10.1016/j.amc.2007.10.065 · DOI
- 10.1109/TNSRE.2004.841384 · DOI · Paper page
- 10.1109/TBME.2013.2243730 · DOI · Paper page
- 10.1109/ICASSP.2005.1416330 · DOI
- lee, 2006, A radial basis classifier for the automatic detection of aspiration in children with dysphagia, J Neuroeng Rehabil, 3, 1, 10.1186/1743-0003-3-14 · DOI · Paper page
- 10.1186/1475-925X-10-100 · DOI
- 10.1186/1475-925X-12-90 · DOI
- 10.1007/s00455-012-9418-9 · DOI · Paper page
- 10.1109/IEMBS.2011.6091735 · DOI
Cited by
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Khalifa, Y., Coyle, J. L., & Sejdić, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65492-1 · Cited by 82
“It also has other disadvantages including radiation exposure and the need for specialized clinicians and equipment 19,21 .”
BackgroundSelf-citationKhalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3000057 · Cited by 49
Self-citationNeck sensor-supported hyoid bone movement tracking during swallowing
Mao, S., Zhang, Z., Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2019) · Royal Society Open Science · doi:10.1098/rsos.181982 · Cited by 47
Self-citationA statistical analysis of cervical auscultation signals from adults with unsafe airway protection
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0110-9 · Cited by 42
“The majority of such studies focused solely on normal swallows from healthy subjects and those that did not often had limited scope or small sample sizes [24].”
BackgroundSelf-citationDonohue, C., Khalifa, Y., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Dysphagia · doi:10.1007/s00455-020-10177-0 · Cited by 41
Self-citationO’Brien, M. K., Botonis, O. K., Larkin, E., Carpenter, J., Martin-Harris, B., Maronati, R., Lee, K., Cherney, L. R., Hutchison, B., Xu, S., et al. (2021) · Digital Biomarkers · doi:10.1159/000517144 · Cited by 37
Kurosu, A., Coyle, J. L., Dudik, J. M., & Sejdic, E. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.05.038 · Cited by 33
Self-citationHigh-resolution cervical auscultation and data science: new tools to address an old problem
Coyle, J. L., & Sejdić, E. (2020) · American Journal of Speech-Language Pathology · doi:10.1044/2020_ajslp-19-00155 · Cited by 28
“HRCA was described by Dudik, Coyle, and Sejdi ć (2015) following 3 years of research that deployed a tri-axial accelerometer and high-resolution microphone to accrue the signals.”
BackgroundMethodInfluentialSelf-citationSilent Aspiration Detection in High Resolution Cervical Auscultations
Yu, C., Khalifa, Y., & Sejdic, E. (2019) · 2019 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2019.8834576 · Cited by 22
Donohue, C., Khalifa, Y., Mao, S., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2021_jslhr-21-00134 · Cited by 15
Self-citationDonohue, C., Khalifa, Y., Mao, S., Perera, S., Sejdić, E., & Coyle, J. L. (2022) · Dysphagia · doi:10.1007/s00455-021-10317-0 · Cited by 12
Self-citationEnz, V. C. Q., Vaz, A. R. C., Nunes, M. C. D. A., Rosa, M. D. O., Nunes, J. D. A., Marques, J. M., & Santos, R. S. (2022) · Dysphagia · doi:10.1007/s00455-021-10358-5 · Cited by 9
Dias, V., & Bolzan, G. D. P. (2021) · Audiology - Communication Research · doi:10.1590/2317-6431-2021-2498 · Cited by 1
Metadata
- Authors
- Dudik, J. M., Coyle, J. L., & Sejdic, E.
- Venue
- IEEE Transactions on Human-Machine Systems
- Published
- 2015-08
- Volume
- 45
- Issue
- 4
- Pages
- 465-477
- ISSN
- 2168-2291 (ISSN-L)
- 2168-2305
- OpenAlex
- W2052000467
- Cited by
- 86
- References
- 12
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- Eunice Kennedy Shriver National Institute Of Child Health and Human Development of the National Institutes of Health (R01HD074819)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.