Abstract
Recent studies suggest that the quality of recovery after a stroke can be increased by early and more intensive rehabilitation. Portable unobtrusive devices are promising candidates for the realization of stroke-rehabilitation systems that complement care in the post-acute rehabilitation phase, both in the clinic and at home. The proposed system allows patients to increase the amount of motor exercise they can perform in autonomy, providing them with a real-time feedback based on wearable sensors embedded in the garment's tissue across the upper limb and trunk. A dynamic time warping algorithm allows for the recognition of correct and incorrect motor exercises. After the feedback phase, data are stored in a central location for review and statistics. Workstations can be installed either at home or at the hospital to support patients, independent of their location. The performance of the system on healthy subjects was quantified for seven types of motor exercises for upper limb's rehabilitation. Finally, we present the preliminary results of a pilot clinical study to test the system's acceptability and usability by post-stroke patients, and physicians in a clinical setting.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Collecting information from the patient during rehabilitation, specifically strain[89] and pressure,[90] can inform the therapist in real-time about the accuracy of the movement as well as the physiological status.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [89]
In the citing paper
“A project that was part of the myHeart initiative [97,98] led to the development of a sensorized garment-based system to facilitate rehabilitation interventions in the home setting.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [98]
Citations
Cites
Fundamentals of speech recognition
Rabiner, L. R., & Juang, B.-H. F. (1993) · Cited by 7,680
Dynamic Programming Algorithm Optimization for Spoken Word Recognition
Sakoe, H., & Chiba, S. (1978) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1978.1163055 · Cited by 6,727
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“The interest in the more widespread integration of telerehabilitation with the clinical practice prompted the exploration of a variety of devices for body motion analysis: stereophotogrammetry [16]–[ 18 ], electromagnetic systems [19]–[21], robots [22], and markerless video-based [23], [24].”
BackgroundRobot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Effects of Augmented Exercise Therapy Time After Stroke: A Meta-Analysis
Kwakkel, G., van Peppen, R., Wagenaar, R. C., Wood Dauphinee, S., Richards, C., Ashburn, A., Miller, K., Lincoln, N., Partridge, C., Wellwood, I., et al. (2004) · Stroke · doi:10.1161/01.str.0000143153.76460.7d · Cited by 1,081
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647 · cited 1×
“Inertial microelectromechanical systems (MEMS) sensors like accelerometers, for example, received wide attention in recent literature due to their low cost, size, and ease of digital processing [ 25 ].”
BackgroundBonita, R., Mendis, S., Truelsen, T., Bogousslavsky, J., Toole, J., & Yatsu, F. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(04)00800-2 · Cited by 437
Impact of intensity of practice after stroke: Issues for consideration
Kwakkel, G. (2006) · Disability and Rehabilitation · doi:10.1080/09638280500534861 · Cited by 417
Human movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Tormene, P., Giorgino, T., Quaglini, S., & Stefanelli, M. (2009) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2008.11.007 · Cited by 287
Self-citationTognetti, A., Lorussi, F., Bartalesi, R., Quaglini, S., Tesconi, M., Zupone, G., & De Rossi, D. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-8 · Cited by 174
Self-citationCourtney, K. L. (2008) · Methods of Information in Medicine · doi:10.3414/me9104 · Cited by 170
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Abdoli-Eramaki, M., & Stevenson, J. M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.10.012 · Cited by 149
Luprano, J., Sola, J., Dasen, S., Koller, J. M., & Chetelat, O. (2006) · International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06) · doi:10.1109/bsn.2006.15 · Cited by 89
Virtual reality based upper extremity rehabilitation following stroke: a review
Cameirão, M. S., Badia, S. B. I., & Verschure, P. F. M. J. (2008) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 83
Wireless orientation sensors: Their suitability to measure head movement for neck pain assessment
Jasiewicz, J. M., Treleaven, J. M., Condie, P., & Jull, G. A. (2006) · Manual Therapy · doi:10.1016/j.math.2006.07.005 · Cited by 68
A smart virtual glove for the hand telerehabilitation
Placidi, G. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.09.011 · Cited by 60
The Italian Guidelines for stroke prevention
Available, N. A. N. (2000) · Neurological Sciences · doi:10.1007/s100720070112 · Cited by 58
A study of the receptivity to telecare technology in a community-based elderly minority population
Bertera, E. M., Tran, B. Q., Wuertz, E. M., & Bonner, A. (2007) · Journal of Telemedicine and Telecare · doi:10.1258/135763307782215325 · Cited by 41
Textile-Based Electrogoniometers for Wearable Posture and Gesture Capture Systems
Lorussi, F., Galatolo, S., & De Rossi, D. E. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2024867 · Cited by 36
Schoch, K. F., & Saunders, H. E. (1992) · IEEE Spectrum · doi:10.1109/6.254021 · Cited by 27
A new method for 3D optical analysis of chest wall motion
Camevali, P., Ferrigno, G., Aliverti, A., & Pedotti, A. (1996) · Technology and Health Care · doi:10.3233/thc-1996-4107 · Cited by 24
Posture Classification via Wearable Strain Sensors for Neurological Rehabilitation
Toni Giorgino, A., Lorussi, F., Rossi, D. D., & Quaglini, S. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260620 · Cited by 22
Self-citationSMART Rehabilitation: Implementation of ICT Platform to Support Home-Based Stroke Rehabilitation
Zheng, H., Davies, R. J., Stone, T., et al. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-73279-2_93 · Cited by 13
Computer-aided therapy in aphasia therapy: evaluation of assignment criteria
Schröder, C., Schupp, W., Seewald, B., & Haase, I. (2007) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0b013e3282f144da · Cited by 11
INZITARI, D. (2000) · Florence Research (University of Florence) · Cited by 9
Upper-limb rehabilitation exercises acquired through 29 elastomer strain sensors placed on fabric
Tormene, P., Giorgino, T., Quaglini, S., et al. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.11229 · Cited by 5
Self-citationIandelli, I., Rosi, E., & Scano, G. (1999) · PubMed · Cited by 4
EvoCare: a new standard in tele-therapy.
Johanni, M., Tietze, D. A., Setz, R., et al. (2004) · PubMed · Cited by 3
Remote support for stroke rehabilitation: MyHeart's "neurological rehabilitation" concept.
Giorgino, T., Tormene, P., Cattani, B., et al. (2007) · PubMed · Cited by 3
Self-citation
Research works printed but not linked: 1
- giorgino, 0, Proc 12th World Congr Health (Med ) Inf (Medinfo 2007), 12 pt 1, 92
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Metadata
- Authors
- Giorgino, T., Tormene, P., Maggioni, G., Pistarini, C., & Quaglini, S.
- Affiliations
- University of Pavia (IT)
- Istituti Clinici Scientifici Maugeri (IT)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2009-11
- Volume
- 13
- Issue
- 6
- Pages
- 1012-1018
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2128799330
- Semantic Scholar
- f82e9435b9baca0cc421630ccc68019c35eec041
- Cited by
- 31
- References
- 31
- Citations by year
- 2023: 1 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 2 · 2014: 5 · 2013: 4 · 2012: 2
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- stroke rehabilitation, wearable sensors, dynamic time warping, real-time feedback, home-based rehabilitation, post-acute rehabilitation, telemedicine
- MeSH terms
- Stroke Rehabilitation, Algorithms, Humans, Software, Telemetry, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.