Design and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper explores the design methodology and effectiveness of small-scale magnetorheological dampers (MRDs) in applications that require variable damping. Previously, applications of MRD have been chiefly limited to vehicle shock absorbers and seismic vibration attenuators. There has been recent biomedical interest in active-damping technology, however, particularly in the field of rehabilitation robotics. The topic at hand is the feasibility of developing MRDs that would be functionally and cosmetically adequate for actuation of an upper limb tremor suppression orthosis. A Bingham plastic model is used to determine MRD's functional characteristics, and experimental data are presented to validate the mathematical model. The feasibility of applying the developed small-scale MRDs to attenuation of tremorous motion is explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 2×
“Thus, while the administration of drugs, stereotactic thalamotomy, or thalamic deep brain stimulation is often initially effective in controlling tremor motion, none of these treatments guarantees a permanent solution [1], [2].”
BackgroundDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“However, the investigators noted that “customization of viscosity or inertia added to the upper limb according to the biomechanical characteristics of each user should improve the efficiency of passive tremor suppression strategy [12].”
BackgroundDeep brain stimulation for essential tremor: a systematic review
Flora, E. D., Perera, C. L., Cameron, A. L., & Maddern, G. J. (2010) · Movement Disorders · doi:10.1002/mds.23195 · Cited by 323
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87 · cited 1×
“” The orthosis proved functionally successful in reducing the amplitude of the patients’ tremor by as much as 90%, though there were some complaints on the aesthetic drawbacks of the device, and the investigators stressed the necessity of further reducing its size and weight [13], [14].”
BackgroundDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×
“This device was designed to be minimally restrictive to natural movement and capable of monitoring and suppressing tremor, employing both active and passive strategies [10], [11].”
MethodLoureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70 · cited 1×
“It allowed adduction/abduction and pronation/supination and added viscous damping to flexion/extension of the wrist [8], [9].”
BackgroundThe effect of mechanical damping loads on disabling action tremor
Aisen, M. L., Arnold, A., Baiges, I., Maxwell, S., & Rosen, M. (1993) · Neurology · doi:10.1212/wnl.43.7.1346 · Cited by 64
Research works printed but not linked: 13
- 10.1080/14734220601103037 · DOI · Paper page
- rocon, 2007, Evaluation of a wearable orthosis and an associaed algorithm for tremor suppression, Physiol Meas, 28, 415, 10.1088/0967-3334/28/4/007 · DOI · Paper page
- rosen, 2007, Upper-limb powered exoskeleton design, IEEE/ASME Trans Mechatronics, 12, 408, 10.1109/TMECH.2007.901934 · DOI · Paper page
- gurocak, 2009, Haptic glove with MR brakes for virtual reality, IEEE/ASME Trans Mechatronics, 14, 606, 10.1109/TMECH.2008.2010934 · DOI · Paper page
- 10.1109/TMECH.2010.2074210 · DOI
- belda-lois, 2005, Estimation of the biomechanical characteristics of tremorous movements based on gyroscopes, Assistive Technol from Virtuality Reality vol 16, 138
- phillips, 1969, Engineering Applications of Fluids with a Variable Yield Stress
- 10.1007/s00415-005-4005-8 · DOI
- 10.1136/jnnp.51.7.934 · DOI · Paper page
- kotovsky, 1998, A wearable tremor-suppression orthosis, J Rehabil Res Develop, 35, 373
- sirisena, 2009, My hands shake: Classification and treatment of tremor, Austral Fam Phys, 38, 678
- belda-lois, 2007, Rehabilitation Robotics Biomechanical Constraints in the Design of Robotic Systems for Tremor Suppression
- 10.1088/0964-1726/5/5/007 · doi:10.1088/0964-1726/5/5/007
Cited by
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
Self-citationZhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.009 · Cited by 46
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
The measurement and analysis of parkinsonian hand tremor
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2016) · 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2016.7455922 · Cited by 33
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
Zamanian, A. H., & Richer, E. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102273 · Cited by 22
Self-citation
Metadata
- Authors
- Case, D., Taheri, B., & Richer, E.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2013-02
- Volume
- 18
- Issue
- 1
- Pages
- 96-103
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2157261759
- Cited by
- 98
- References
- 7
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression. https://app.cochat.ai/papers/10.1109/tmech.2011.2151204
- The paper
- Case, D., Taheri, B., & Richer, E. (2013). Design and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2011.2151204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.