The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 901–1,000 of 1,000
Three-dimensional motion estimation with image reconstruction for gated cardiac ECT
Cao, Z., Gilland, D. R., Mair, B. A., & Jaszczak, R. J. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.812444 · Cited by 31
THE NOISY EXPECTATION–MAXIMIZATION ALGORITHM
Osoba, O., Mitaim, S., & Kosko, B. (2013) · Fluctuation and Noise Letters · doi:10.1142/s0219477513500120 · Cited by 31
Denoising of Dynamic Sinogram by Image Guided Filtering for Positron Emission Tomography
Hashimoto, F., Ohba, H., Ote, K., & Tsukada, H. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2869936 · Cited by 31
Super-resolution in computational imaging
Bertero, M., & Boccacci, P. (2003) · Micron · doi:10.1016/s0968-4328(03)00051-9 · Cited by 31
Restoration of interferometric images
Carbillet, M., Correia, S., Boccacci, P., & Bertero, M. (2002) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20020389 · Cited by 31
Scatter correction for positron emission mammography
Qi, J., & Huesman, R. H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/315 · Cited by 31
Kontaxakis, G. (2002) · Molecular Imaging and Biology · doi:10.1016/s1536-1632(02)00004-5 · Cited by 31
Unfolding by weighting Monte Carlo events
Lindemann, L., & Zech, G. (1995) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(94)01067-6 · Cited by 31
Fast PET image reconstruction based on SVD decomposition of the system matrix
Selivanov, V. V., & Lecomte, R. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.940160 · Cited by 31
Gullberg, G. T., Zeng, G. L., Tsui, B. M. W., & Hagius, J. T. (1989) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850010207 · Cited by 31
Iterative reconstruction-reprojection and the expectation-maximization algorithm
Ollinger, J. M. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52986 · Cited by 31
Tomographic radiopharmaceutical imaging
Jasczak, R. J. (1988) · Proceedings of the IEEE · doi:10.1109/5.9654 · Cited by 31
Reconstruction d’image : régularisation avec prise en compte des discontinuités.
Charbonnier, P. (1994) · Cited by 31
Unsupervised Web Topic Detection Using A Ranked Clustering-Like Pattern Across Similarity Cascades
Pang, J., Jia, F., Zhang, C., Zhang, W., Huang, Q., & Yin, B. (2015) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2015.2425143 · Cited by 30
A collimator optimization method for quantitative imaging: Application to Y-90 bremsstrahlung SPECT
Rong, X., & Frey, E. C. (2013) · Medical Physics · doi:10.1118/1.4813297 · Cited by 30
An anatomically driven anisotropic diffusion filtering method for 3D SPECT reconstruction
Kazantsev, D., Arridge, S., Pedemonte, S., Bousse, A., Erlandsson, K., Hutton, B. F., & Sebastien Ourselin, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/12/3793 · Cited by 30
Kinetic filtering of [18F]Fluorothymidine in positron emission tomography studies
Gray, K. R., Contractor, K. B., Kenny, L. M., AL-NAHHAS, A. M., Shousha, S., Stebbing, J., Wasan, H. S., Coombes, R. C., Aboagye, E. O., Turkheimer, F., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/3/010 · Cited by 30
Iterative Image Reconstruction Using Inverse Fourier Rebinning for Fully 3-D PET
Cho, S., Li, Q., Ahn, S., Bai, B., & Leahy, R. M. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.887378 · Cited by 30
Intercomparison of MR‐informed PET image reconstruction methods
Bland, J., Mehranian, A., Belzunce, M. A., Ellis, S., da Costa-Luis, C. O., McGinnity, C. J., Hammers, A., & Reader, A. J. (2019) · Medical Physics · doi:10.1002/mp.13812 · Cited by 30
A Learned Reconstruction Network for SPECT Imaging
Shao, W., Pomper, M. G., & Du, Y. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2994041 · Cited by 30
Tsuchiya, J., Yokoyama, K., Yamagiwa, K., Watanabe, R., Kimura, K., Kishino, M., Chan, C., Asma, E., & Tateishi, U. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00377-4 · Cited by 30
The Evolution of Image Reconstruction in PET
Gong, K., Kim, K., Cui, J., Wu, D., & Li, Q. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.004 · Cited by 30
Neutron and gamma imaging using an organic glass scintillator handheld dual particle imager
Lopez, R., Steinberger, W. M., Giha, N. P., Marleau, P. A., Clarke, S. D., & Pozzi, S. A. (2022) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2022.167407 · Cited by 30
Mishra, V. D., Negi, H. S., Rawat, A. K., Chaturvedi, A. K., & Singh, R. P. (2009) · International Journal of Remote Sensing · doi:10.1080/01431160802651959 · Cited by 30
Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system
Zeraatkar, N., Sajedi, S., Farahani, M. H., Arabi, H., Sarkar, S., Ghafarian, P., Rahmim, A., & Ay, M. R. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.013 · Cited by 30
OS-EM and FBP reconstructions at low count rates: effect on 3D PET studies of [11C] WAY-100635
Bélanger, M.-J., Mann, J. J., & Parsey, R. V. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.035 · Cited by 30
Radioactive Source Estimation Using a System of Directional and Non-Directional Detectors
Deb, B., Ross, J. A. F., Iván, A., & Hartman, M. J. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2165558 · Cited by 30
A Fast Algorithm for Deconvolution and Poisson Noise Removal
Zhang, X., Ng, M. K., & Bai, M. (2017) · Journal of Scientific Computing · doi:10.1007/s10915-017-0597-2 · Cited by 30
3D-OSEM iterative image reconstruction for high-resolution PET using precalculated system matrix
Ortuño, J. E., Guerra, P., Rubio, J. L., Kontaxakis, G., & Santos, A. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.08.067 · Cited by 30
On an iterative method for a class of integral equations of the first kind
Mülthei, H. N., Schorr, B., & Törnig, W. (1987) · Mathematical Methods in the Applied Sciences · doi:10.1002/mma.1670090112 · Cited by 30
A maximum-likelihood reconstruction algorithm for tomographic gamma-ray nondestructive assay
Prettyman, T. H., Cole, R., Estep, R. J., & Sheppard, G. A. (1995) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(94)01352-7 · Cited by 30
Absolute quantitation of myocardial activity in phantoms
Silva, A. J. D., Tang, H. R., Wu, M. C., & Hasegawa, B. H. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775595 · Cited by 30
Multiplicative iterative methods in computed tomography
Pierro, Á. R. D. (1991) · Lecture notes in mathematics · doi:10.1007/bfb0084517 · Cited by 30
An iterative algorithm for X-ray CT fluoroscopy
Wang, G., Schweiger, G. D., & Vannier, M. W. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736058 · Cited by 30
Evaluation of the ordered subset convex algorithm for cone-beam CT
Kole, J. S., & Beekman, F. J. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/004 · Cited by 30
Politte, D. G., & Snyder, D. L. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333330 · Cited by 30
Labbé, C., Thielemans, K., Zaidi, H., & Morel, C. (1999) · Cited by 30
X‐ray fluorescence computed tomography with absorption correction for biomedical samples
Yang, Q., Deng, B., Du, G., Xie, H., Zhou, G., Xiao, T., & Xu, H. (2014) · X-Ray Spectrometry · doi:10.1002/xrs.2550 · Cited by 29
Conditional Variational Autoencoder for Learned Image Reconstruction
Zhang, C., Barbano, R., & Jin, B. (2021) · Computation · doi:10.3390/computation9110114 · Cited by 29
Murari, A., Rossi, R., Craciunescu, T., Vega, J., Contributors, J., Mailloux, J., Abid, N., Abraham, K., Abreu, P., Adabonyan, O., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-46242-7 · Cited by 29
Zeng, G. L., Li, Y., & Zamyatin, A. A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/10/3413 · Cited by 29
AB-OSEM reconstruction for improved Patlak kinetic parameter estimation: a simulation study
Verhaeghe, J. A. J., & Reader, A. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/009 · Cited by 29
Seetharaman, K. M. R., & Palanivel, N. (2013) · International Journal of Image and Data Fusion · doi:10.1080/19479832.2013.804007 · Cited by 29
SNARK09 – A software package for reconstruction of 2D images from 1D projections
Klukowska, J., Davidi, R., & Herman, G. T. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.01.003 · Cited by 29
Ravi, M., Sewa, A., Shashidhar, T. G., & Sanagapati, S. S. S. (2019) · IEEE Access · doi:10.1109/access.2019.2932647 · Cited by 29
Deep Kernel Representation for Image Reconstruction in PET
Li, S., & Wang, G. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3176002 · Cited by 29
Iterative blind deconvolution in magnetic resonance brain perfusion imaging
Grüner, R., & Taxt, T. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20850 · Cited by 29
Metal artifact reduction in CT by identifying missing data hidden in metals
Park, H. S., Choi, J. K., Park, K.-R., Kim, K. S., Lee, S.-H., Ye, J. C., & Seo, J. K. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130384 · Cited by 29
Improved Reconstruction for MR Spectroscopic Imaging
Bao, Y., & Maudsley, A. A. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.895482 · Cited by 29
Volegov, P. L., Danly, C. R., Merrill, F. E., Simpson, R. A., & Wilde, C. H. (2015) · Journal of Applied Physics · doi:10.1063/1.4936319 · Cited by 29
Software-Based Real-Time Acquisition and Processing of PET Detector Raw Data
Goldschmidt, B., Schug, D., Lerche, C. W., Salomon, A., Gebhardt, P., Weissler, B., Wehner, J., Dueppenbecker, P. M., Kiessling, F. M., & Schulz, V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2456640 · Cited by 29
Liu, J., Huang, T., Lv, X.-G., & Wang, S. (2017) · Applied Mathematical Modelling · doi:10.1016/j.apm.2017.01.009 · Cited by 29
Spatially Compact MR-Guided Kernel EM for PET Image Reconstruction
Bland, J., Belzunce, M. A., Ellis, S., McGinnity, C. J., Hammers, A., & Reader, A. J. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2844559 · Cited by 29
Deep Learning Based Framework for Direct Reconstruction of PET Images
Liu, Z., Chen, H., & Liu, H. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32248-9_6 · Cited by 29
Murase, K., Tanada, S., Inoue, T., Sugawara, Y., & Hamamoto, K. (1993) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02261243 · Cited by 29
A family of $\pi$-scheme exponential Radon transforms and the uniqueness of their inverses
Pan, X., Kao, C.-M., & Metz, C. E. (2002) · Inverse Problems · doi:10.1088/0266-5611/18/3/319 · Cited by 29
Politte, D. G. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106707 · Cited by 29
Compton Cameras for Nuclear Medical Imaging
Rogers, W. L., Clinthorne, N. H., & Bolozdynya, A. I. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50022-3 · Cited by 29
Hsiao, I., Rangarajan, A., & Gindi, G. R. (2003) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2002.1029281 · Cited by 29
LaCroix, K. J., Tsui, B. M. W., & Hasegawa, B. H. (1998) · PubMed · Cited by 29
Space-Time Gibbs Priors Applied to Gated SPECT Myocardial Perfusion Studies
Lalush, D. S., & Tsui, B. M. W. (1996) · Computational imaging and vision · doi:10.1007/978-94-015-8749-5_15 · Cited by 29
Correction for Partial Volume Effects in Emission Tomography
ROUSSET, O. G., & Zaidi, H. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_8 · Cited by 29
Image reconstruction using UNET-transformer network for fast and low-dose PET scans
Kaviani, S. I., Sanaat, A., Mokri, M., Cohalan, C., & Carrier, J. (2023) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2023.102315 · Cited by 28
Cade, S. C., Arridge, S., Evans, M. J., & Hutton, B. F. (2013) · Medical Physics · doi:10.1118/1.4812686 · Cited by 28
A Bayesian MAP-EM Algorithm for PET Image Reconstruction Using Wavelet Transform
Zhou, J., Coatrieux, J.-L., Bousse, A., Shu, H., & Luo, L. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2007.901200 · Cited by 28
Initial assessment of image quality for low-dose PET: evaluation of lesion detectability
Schaefferkoetter, J. D., Yan, J., Townsend, D. W., & Conti, M. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5543 · Cited by 28
PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques
Lillington, J., Brusaferri, L., Kläser, K., Shmueli, K., Neji, R., Hutton, B. F., Fraioli, F., Arridge, S., Cardoso, M. J., Sebastien Ourselin, A., et al. (2019) · Medical Physics · doi:10.1002/mp.13943 · Cited by 28
Speed of sound ultrasound transmission tomography image reconstruction based on Bézier curves
Pérez-Liva, M., Udías, J. M., Camacho, J., Merčep, E., Deán‐Ben, X. L., Razansky, D., & Herraiz, J. L. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106097 · Cited by 28
Vavrek, J. R., Hellfeld, D., Bandstra, M. S., Negut, V., Meehan, K., Vanderlip, W. J., Cates, J. W., Pavlovsky, R. T., Quiter, B. J., Cooper, R. J., et al. (2020) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2020.3024735 · Cited by 28
Penalized-Likelihood PET Image Reconstruction Using 3D Structural Convolutional Sparse Coding
Xie, N., Gong, K., Guo, N., Qin, Z., Wu, Z., Liu, H., & Li, Q. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3042907 · Cited by 28
Marshall, M., Hellfeld, D., Joshi, T. H. Y., Salathe, M., Bandstra, M. S., Bilton, K. J., Cooper, R. J., Curtis, J. C., Negut, V., Shurley, A. J., et al. (2020) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2020.3047646 · Cited by 28
PET respiratory motion correction: quo vadis?
Lamare, F., Bousse, A., Thielemans, K., Liu, C., Merlin, T., Fayad, H. J., & Visvikis, D. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac43fc · Cited by 28
Ma, R., Hu, J., Sari, H., Xue, S., Mingels, C., Viscione, M., Kandarpa, V. S. S., Li, W. B., Visvikis, D., Qiu, R., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05861-2 · Cited by 28
Li, Z., Benabdallah, N., Abou, D. S., Baumann, B. C., Dehdashti, F., Ballard, D. H., Liu, J., Jammalamadaka, U. M., Laforest, R. A., Wahl, R. L., et al. (2022) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2022.3175435 · Cited by 28
Numerical Methods for Parameter Estimation in Poisson Data Inversion
Zanni, L., Benfenati, A., Bertero, M., & Ruggiero, V. (2014) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-014-0553-9 · Cited by 28
Brennan, J., Brubaker, E., Cooper, R. L., Gerling, M. D., Greenberg, C. H., Marleau, P. A., Mascarenhas, N., & Mrowka, S. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2163192 · Cited by 28
Zhou, J., & Qi, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/541 · Cited by 28
Nuyts, J. L., Michel, C. J., Brepoels, L., Ceuninck, L. D., Deroose, C. M., Goffin, K. E., Mottaghy, F. M., Stroobants, S. G., Riet, J. V., & Verscuren, R. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927349 · Cited by 28
Kao, C.-M., Pan, X., & Chen, C.-T. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873015 · Cited by 28
Bounded perturbation resilience of projected scaled gradient methods
Jin, W., Censor, Y., & Jiang, M. F. (2015) · Computational Optimization and Applications · doi:10.1007/s10589-015-9777-x · Cited by 28
Performance of a Fast Maximum Likelihood Algorithm for Fully 3D PET Reconstruction
Matej, S., & Browne, J. A. (1996) · Computational imaging and vision · doi:10.1007/978-94-015-8749-5_21 · Cited by 28
Novel Algorithm for Tomographic Reconstruction of Atmospheric Chemicals with Sparse Sampling
Verkruysse, W., & Todd, L. A. (2005) · Environmental Science & Technology · doi:10.1021/es035231v · Cited by 28
Kneifel, S., Bernhardt, P., Uusijärvi, H., Good, S., Plaßwilm, L., Buitrago-Téllez, C. H., Müller‐Brand, J., Mäcke, H. R., & Merlo, A. U. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0351-8 · Cited by 28
Anatomical based FDG-PET reconstruction for the detection of hypometabolic regions in epilepsy
Baete, K., Nuyts, J. L., Paesschen, W. V., Suetens, P., & Dupont, P. J. (2003) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2002.1239601 · Cited by 28
Calculation of the Sensitivity Image in List-Mode Reconstruction for PET
Qi, J. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.882298 · Cited by 28
Iterative Reconstruction Methods for Non Uniform Attenuation Distribution in Spect
Maze, A., Collorec, Bourguet, & Pierfittte (1992) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1992.590162 · Cited by 28
Fundamental limits of positron emission mammography
Moses, W. W., & Qi, J. (2003) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(02)01895-8 · Cited by 28
Tomographic reconstruction using 3D deformable models
Battle, X. L., Cunningham, G. S., & Hanson, K. M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/025 · Cited by 28
Mesina, C. T., Boellaard, R., Jongbloed, G., van der Vaart, A., & Lammertsma, A. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00075-2 · Cited by 28
Cross Burg entropy maximization and its application to ringing suppression in image reconstruction
Cao, Y., Eggermont, P. P. B., & Terebey, S. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.743861 · Cited by 28
A study of bias for various iterative reconstruction methods in PET
Hogg, D., Thielemans, K., Mustafovic, S., & Spinks, T. J. (2003) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2002.1239610 · Cited by 28
Overview of Bayesian methods in image reconstruction
Lange, K. L. (1990) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.23640 · Cited by 28
Reduction of truncation artifacts in fan beam transmission by using parallel beam emission data
Pan, T., King, M. A., Penney, B. C., Rajeevan, N., Luo, D.-S., & Case, J. A. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467864 · Cited by 28
Characterization of Metal Artifacts in X-ray Computed TomographyPreprint
Suk, H., Jae, P., Jin, K. C., & Seo, K. (2016) · Cited by 28
3D image scanning microscopy with engineered excitation and detection
Roider, C., Piestun, R., & Jesacher, A. (2017) · Optica · doi:10.1364/optica.4.001373 · Cited by 27
Sheet beam x‐ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles
Dunning, C. A. S., & Bazalova‐Carter, M. (2018) · Medical Physics · doi:10.1002/mp.12893 · Cited by 27
Sui, X., Tan, H., Yu, H., Xiao, J., Qi, C., Cao, Y., Chen, S., Zhang, Y., Hu, P., & Shi, H. (2022) · EJNMMI Physics · doi:10.1186/s40658-022-00445-3 · Cited by 28
Automated analysis of rotating probe multi-frequency eddy current data from steam generator tubes
Xiang, P., Ramakrishnan, S., Cai, X., Ramuhalli, P., Robi Polikar, A., Udpa, S. S., & Удпа, Л. (2000) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-2000-216 · Cited by 27
TomoTherapy MLC verification using exit detector data
Chen, Q., Westerly, D., Fang, Z., Sheng, K., & Chen, Y. (2011) · Medical Physics · doi:10.1118/1.3666762 · Cited by 27
Tomographic retrieval of the oxygen infrared atmospheric band with the OSIRIS infrared imager
Degenstein, D. A., Llewellyn, E. J., & Lloyd, N. D. (2004) · Canadian Journal of Physics · doi:10.1139/p04-024 · Cited by 27
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review