The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 501–600 of 1,000
Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering*
Jacobson, M. W., Levkovitz, R., Ben‐Tal, A., Thielemans, K., Spinks, T. J., Belluzzo, D., Pagani, E., Bettinardi, V., Gilardi, M. C., Zverovich, A., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/8/325 · Cited by 61
THE SOLAR WIND NEON ABUNDANCE OBSERVED WITHACE/SWICS ANDULYSSES/SWICS
Shearer, P., Steiger, R. V., Raines, J. M., Lepri, S. T., Thomas, J. W., Gilbert, J. A., Landi, E., & Zurbuchen, T. H. (2014) · The Astrophysical Journal · doi:10.1088/0004-637x/789/1/60 · Cited by 61
Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation
Metzler, S. D., Jaszczak, R. J., Patil, N. H., Vemulapalli, S., Akabani, G., & Chin, B. B. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848357 · Cited by 61
Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.
Tang, H. R., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (2001) · PubMed · Cited by 61
An evaluation of maximum likelihood reconstruction for SPECT
Chornoboy, E. S., Chen, C. J., Miller, M. I., Miller, T. R., & Snyder, D. L. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52987 · Cited by 61
On the efficiency of iterative ordered subset reconstruction algorithms for acceleration on GPUs
Xu, F., Xu, W., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.003 · Cited by 63
Jacobsen, C. J. (2019) · Cambridge University Press eBooks · doi:10.1017/9781139924542 · Cited by 66
Single and Multipinhole Collimator Design Evaluation Method for Small Animal SPECT
Vunckx, K., Beque, D., Defrise, M., & Nuyts, J. L. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.902802 · Cited by 60
Attenuation, Scatter, and Spatial Resolution Compensation in SPECT
King, M. A., Glick, S. J., Pretorius, P. H., Wells, R. G., Gifford, H. C., Narayanan, M. V., & Farncombe, T. H. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50025-9 · Cited by 60
Comparison of Image Quality of Different Iodine Isotopes (I-123, I-124, and I-131)
Rault, E., Vandenberghe, S., Holen, R. V., Beenhouwer, J. D., Staelens, S. G., & Lemahieu, I. A. (2007) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2006.323 · Cited by 60
Walrand, S., Jamar, F., de Jong, M., & Pauwels, S. (2005) · PubMed · Cited by 60
Liang, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293924 · Cited by 60
On complete-data spaces for PET reconstruction algorithms
Fessler, J. A., Clinthorne, N. H., & Rogers, W. L. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/23.256712 · Cited by 60
Evaluation of the TierPET system
Weber, S., Herzog, H. R., Cremer, M., Engels, R., Hamacher, K., Kehren, F., Mühlensiepen, H., Ploux, L., Reinartz, R., Reinhart, P., et al. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.790853 · Cited by 60
Pinoli, J. (1997) · Signal Processing · doi:10.1016/s0165-1684(97)00011-x · Cited by 62
A filtered backprojection algorithm with characteristics of the iterative landweber algorithm
Zeng, G. L. (2012) · Medical Physics · doi:10.1118/1.3673956 · Cited by 59
Iterative Optimization in Inverse Problems
Byrne, C. L. (2014) · Chapman & Hall/CRC eBooks · doi:10.1201/b16485 · Cited by 59
Maximum smoothed likelihood for multivariate mixtures
Levine, M., Hunter, D. R., & Chauveau, D. (2011) · Biometrika · doi:10.1093/biomet/asq079 · Cited by 59
Advances in PET/MR instrumentation and image reconstruction
Cabello, J., & Ziegler, S. I. (2016) · British Journal of Radiology · doi:10.1259/bjr.20160363 · Cited by 59
Pan, X., & Metz, C. E. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.476107 · Cited by 59
Wavelet‐Based Image Deconvolution and Reconstruction
Pustelnik, N., Benazza-Benhayia, A., Zheng, Y., & Pesquet, J.-C. (2016) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w8294 · Cited by 59
EM-TV Methods for Inverse Problems with Poisson Noise
Sawatzky, A., Brüne, C., Kösters, T., Wübbeling, F., & Burger, M. (2013) · Lecture notes in mathematics · doi:10.1007/978-3-319-01712-9_2 · Cited by 58
Chlewicki, W., Hermansen, F., & Hansen, S. B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/20/004 · Cited by 58
Dai, X., Shu, H., Luo, L., Han, G.-N., & Coatrieux, J.-L. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2009.07.009 · Cited by 58
Regional Correlation between Resting State FDG PET and pCASL Perfusion MRI
Cha, Y.-H. K., Jog, M., Kim, Y., Chakrapani, S., Kraman, S. M., & Wang, D. J. J. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.147 · Cited by 58
Yokei, T., Shinohara, H., & Onishi, H. (2002) · Annals of Nuclear Medicine · doi:10.1007/bf02995286 · Cited by 58
Non-Gaussian space-variant resolution modelling for list-mode reconstruction
Cloquet, C., Sureau, F. C., Defrise, M., Simaeys, G. V., Trotta, N., & Goldman, S. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/17/011 · Cited by 58
Sah, B.-R., Stolzmann, P., Delso, G., Wollenweber, S. D., Hüllner, M. W., Hakami, Y. A., Queiroz, M. A., Barbosa, F. D. G., von Schulthess, G. K., Pietsch, C., et al. (2016) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000604 · Cited by 58
Data Unfolding Methods in High Energy Physics
Schmitt, S. (2017) · EPJ Web of Conferences · doi:10.1051/epjconf/201713711008 · Cited by 58
FBP-Net for direct reconstruction of dynamic PET images
Wang, B., & Liu, H. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abc09d · Cited by 58
First achievement of less than 1 mm FWHM resolution in practical semiconductor animal PET scanner
Ishii, K., Kikuchi, Y., Matsuyama, S., Kanai, Y., Kotani, K., Itô, T., Yamazaki, H., Funaki, Y., Iwata, R., Itoh, M., et al. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.03.018 · Cited by 58
Imaging acousto-optic tunable filter with 035-micrometer spatial resolution
Wachman, E. S., Niu, W., & Farkas, D. L. (1996) · Applied Optics · doi:10.1364/ao.35.005220 · Cited by 58
Weight assignment for adaptive image restoration by neural networks
Perry, S. W., & Guan, L. (2000) · IEEE Transactions on Neural Networks · doi:10.1109/72.822518 · Cited by 58
Reconstruction of two- and three-dimensional images from synthetic-collimator data
Wilson, D. W., Barrett, H. H., & Clarkson, E. W. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870252 · Cited by 58
Penney, B. C., King, M. A., & Knešaurek, K. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106698 · Cited by 58
Development of iterative algorithms for image reconstruction
Jiang, M. F., & Wang, G. (2002) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2002-00059 · Cited by 57
Deb, B. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2247060 · Cited by 57
A comparison of four reconstruction methods for JET neutron and gamma tomography
Craciunescu, T., Bonheure, G., Kiptily, V., Murari, A., Tiseanu, I., & Zoita, V. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.224 · Cited by 57
Discretization of the radon transform and of its inverse by spline convolutions
Horbelt, S., Liebling, M., & Unser, M. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1000260 · Cited by 57
Computed Tomography-Based Spectral Imaging For Fluorescence Microscopy
Ford, B. K., Volin, C., Murphy, S. M., Lynch, R. M., & Descour, M. R. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76077-8 · Cited by 57
Snapshot Hyperspectral Volumetric Microscopy
Wu, J., Xiong, B., Lin, X., He, J., Suo, J., & Dai, Q. (2016) · Scientific Reports · doi:10.1038/srep24624 · Cited by 57
Recent Advances in X-ray Cone-beam Computed Laminography
O’Brien, N. S., Boardman, R., Sinclair, I., & Blumensath, T. (2016) · Journal of X-Ray Science and Technology · doi:10.3233/xst-160581 · Cited by 57
A review on biomedical image processing and future trends
Dhawan, A. P. (1990) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(90)90001-p · Cited by 57
Selection of task-dependent diffusion filters for the post-processing of SPECT images
Beekman, F. J., Slijpen, E. T. P., & Niessen, W. J. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/6/024 · Cited by 57
Statistical stopping criteria for iterative maximum likelihood reconstruction of emission images
Herbert, T. J. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/003 · Cited by 57
Mollet, P., Keereman, V., Clementel, E., & Vandenberghe, S. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2198831 · Cited by 56
Factor analysis witha prioriknowledge - application in dynamic cardiac SPECT
Sitek, A., DiBella, E., & Gullberg, G. T. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/9/314 · Cited by 56
Practical Spectral Photography
Habel, R., Kudenov, M. W., & Wimmer, M. H. (2012) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2012.03024.x · Cited by 56
Hybrid scatter correction applied to quantitative holmium-166 SPECT
de Wit, T. C., Xiao, J., Nijsen, J. F. W., Schip, F. V. H., Staelens, S. G., van Rijk, P. P., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/19/004 · Cited by 56
Volume emission rate tomography from a satellite platform
Degenstein, D. A., Llewellyn, E. J., & Lloyd, N. D. (2003) · Applied Optics · doi:10.1364/ao.42.001441 · Cited by 56
Characterization and suppression of edge and aliasing artefacts in iterative x-ray CT reconstruction
Zbijewski, W. B., & Beekman, F. J. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/010 · Cited by 56
Schmidlin, P. (1994) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00238116 · Cited by 56
Chen, S., Liu, H., Shi, P., & Chen, Y. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/807 · Cited by 55
O’Halloran, R., Wen, Z., Holmes, J. H., & Fain, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21439 · Cited by 55
III Super-Resolution by Data Inversion
Bertero, M., & Mol, C. D. (1996) · Progress in optics · doi:10.1016/s0079-6638(08)70314-7 · Cited by 55
Wang, C. X., Snyder, W. E., Bilbro, G. L., & Santago, P. (1998) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(97)00031-0 · Cited by 55
The application of PET to quality assurance of heavy-ion tumor therapy
Enghardt, W., Debus, J., Haberer, T., Hasch, B. G., Hinz, R., Jäkel, O., Krämer, M., Lauckner, K., & Pawelke, J. (1999) · Strahlentherapie und Onkologie · doi:10.1007/bf03038884 · Cited by 55
Kempen, V., & A, L. J. V. V. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00671.x · Cited by 55
Fast SPECT simulation including object shape dependent scatter
Beekman, F. J., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387709 · Cited by 55
Martin, W. R. W. (1986) · Neurology · doi:10.1212/wnl.36.12.1629 · Cited by 55
Representation of photon limited data in emission tomography using origin ensembles
Sitek, A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/009 · Cited by 54
Martínez-Murcia, F. J., Górriz, J. M., Ramı́rez, J., Illán, I. A., & Ortíz, A. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.01.054 · Cited by 54
3D imaging of transition metals in the zebrafish embryo by X-ray fluorescence microtomography
Bourassa, D., Gleber, S.-C., Vogt, S., Yi, H. L., Will, F., Richter, H., Shin, C. H., & Fahrni, C. J. (2014) · Metallomics · doi:10.1039/c4mt00121d · Cited by 54
Parallelizable Bayesian tomography algorithms with rapid, guaranteed convergence
Zheng, J., Saquib, S. S., Sauer, K. D., & Bouman, C. A. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869186 · Cited by 54
Artificial Neural Network Enhanced Bayesian PET Image Reconstruction
Yang, B., Ying, L. L., & Tang, J. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2803681 · Cited by 55
Gaitanis, A., Kontaxakis, G., Spyrou, G. M., Panayiotakis, G., & Tzanakos, G. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2009.07.006 · Cited by 54
Application of the EM algorithm for the multitarget/multisensor tracking problem
Molnar, K. J., & Modestino, J. W. (1998) · IEEE Transactions on Signal Processing · doi:10.1109/78.651193 · Cited by 54
Fully Bayesian Reconstructions From Single-Photon Emission Computed Tomography Data
Weir, I. S. (1997) · Journal of the American Statistical Association · doi:10.1080/01621459.1997.10473602 · Cited by 54
Coincidence imaging with a dual-head scintillation camera.
Patton, J. A., & Turkington, T. G. (1999) · PubMed · Cited by 54
Regularized Image Reconstruction Algorithms for Positron Emission Tomography
Chang, J., Anderson, J. M. M., & Votaw, J. R. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.831224 · Cited by 53
Bao, Q., & Chatziioannou, A. F. (2010) · Medical Physics · doi:10.1118/1.3495817 · Cited by 53
Improved nano-particle tracking analysis
Walker, J. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/6/065605 · Cited by 53
Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction
Scheins, J. J., Boschen, F., & Herzog, H. R. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880679 · Cited by 53
A reweighted $l^2$ method for image restoration with Poisson and mixed Poisson-Gaussian noise
Li, J., Shen, Z., Yin, R., & Zhang, X. (2015) · Inverse Problems and Imaging · doi:10.3934/ipi.2015.9.875 · Cited by 53
Stanley, B. J., Szabelski, P., Chen, Y.-B., Sellergren, B., & Guiochon, G. A. (2003) · Langmuir · doi:10.1021/la020747y · Cited by 53
Smith, M. F., Raylman, R. R., Majewski, S., & Weisenberger, A. G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/022 · Cited by 53
A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals
Loudos, G. K., Nikita, K. S., Giokaris, N. D., Styliaris, E., Archimandritis, S. C., Varvarigou, A. D., Papanicolas, C. N., Majewski, S., Weisenberger, D., Pani, R., et al. (2003) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(03)00025-3 · Cited by 53
Holmes, T. J., & Liu, Y.-H. (1989) · Applied Optics · doi:10.1364/ao.28.004930 · Cited by 53
Kao, C.-M., Yap, J. T., Mukherjee, J., & Wernick, M. N. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650871 · Cited by 53
Coakley, K. J. (1991) · IEEE Transactions on Nuclear Science · doi:10.1109/23.64635 · Cited by 53
Gilland, D. R., Jaszczak, R. J., Wang, H., Turkington, T. G., Greer, K. L., & Coleman, R. E. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/017 · Cited by 53
The EM Algorithm: A Guided Tour
Couvreur, C. (1997) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-1996-5_12 · Cited by 52
Hybrid Imaging: Instrumentation and Data Processing
Cal-González, J., Rausch, I., Sundar, L. K. S., Lassen, M. L., Muzik, O., Moser, E., Papp, L., & Beyer, T. (2018) · Frontiers in Physics · doi:10.3389/fphy.2018.00047 · Cited by 52
Parametric deconvolution of positive spike trains
Li, L., & Speed, T. P. (2000) · The Annals of Statistics · doi:10.1214/aos/1015957394 · Cited by 52
Pan, T., King, M. A., de Vries, D. J., & Ljungberg, M. H. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481437 · Cited by 52
Attenuation correction for small animal SPECT imaging using x‐ray CT data
Hwang, A. B., & Hasegawa, B. H. (2005) · Medical Physics · doi:10.1118/1.1984347 · Cited by 52
Likelihood maximization for list-mode emission tomographic image reconstruction
Byrne, C. L. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959305 · Cited by 52
Kullback proximal algorithms for maximum-likelihood estimation
Chrétien, S., & Hero, A. O. (2000) · IEEE Transactions on Information Theory · doi:10.1109/18.857792 · Cited by 52
Imaging multi-energy gamma-ray fields with a Compton scatter camera
Martin, J., Dogan, N., Gormley, J. E., Knoll, G. F., O’Donnell, M. P., & Wehe, D. K. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.322851 · Cited by 52
Discretization effects in statistical inverse problems
Johnstone, I. M., & Silverman, B. W. (1991) · Journal of Complexity · doi:10.1016/0885-064x(91)90042-v · Cited by 52
Penalized-likelihood image reconstruction for x-ray fluorescence computed tomography
Rivière, P. J. L., Billmire, D. M., Vargas, P., Rivers, M. L., & Sutton, S. R. (2006) · Optical Engineering · doi:10.1117/1.2227273 · Cited by 51
Bregman-EM-TV Methods with Application to Optical Nanoscopy
Brüne, C., Sawatzky, A., & Burger, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02256-2_20 · Cited by 51
A new iterative algorithm to reconstruct the refractive index
Liu, Y., Zhu, P., Chen, B., Wang, J. Y., Yuan, Q., Huang, W., Shu, H., Li, E. R., Liu, X. S., Zhang, K., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/l01 · Cited by 51
Discrete tomography in medical imaging
Herman, G. T., & Kuba, A. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817871 · Cited by 51
Statistical Image Reconstruction for Inconsistent CT Projection Data
Oehler, M., & Buzug, T. M. (2007) · Methods of Information in Medicine · doi:10.1160/me9041 · Cited by 51
Liu, Y., Kiss, A. M., Larsson, D. H., Yang, F., & Pianetta, P. (2016) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2016.01.002 · Cited by 51
Hybrid PET-MR list-mode kernelized expectation maximization reconstruction
Deidda, D., Karakatsanis, N. A., Robson, P. M., Tsai, Y., Efthimiou, N., Thielemans, K., Fayad, Z. A., Aykroyd, R. G., & Tsoumpas, C. (2019) · Inverse Problems · doi:10.1088/1361-6420/ab013f · Cited by 51
Generative adversarial network based regularized image reconstruction for PET
Xie, Z., Baikejiang, R., Li, T., Zhang, X., Gong, K., Zhang, M., Qi, W., Asma, E., & Qi, J. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab8f72 · Cited by 54
Deep learning with noise‐to‐noise training for denoising in SPECT myocardial perfusion imaging
Liu, J., Yang, Y., Wernick, M. N., Pretorius, P. H., & King, M. A. (2020) · Medical Physics · doi:10.1002/mp.14577 · Cited by 50
Qi, J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.824239 · Cited by 51
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review