The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 601–700 of 1,000
Evaluation of OS-EM vs. ML-EM for 1D, 2D and fully 3D SPECT reconstruction
Kamphuis, C., Beekman, F. J., & Viergever, M. A. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.507262 · Cited by 51
Delbeke, D., Patton, J. A., Martin, W. H., & Sandler, M. P. (1999) · PubMed · Cited by 51
Haberkorn, U., Bellemann, M. E., Altmann, A., Gerlach, L., Morr, I., Oberdorfer, F., Brix, G., Doll, J., Blatter, J., & KAICK, G. V. (1997) · PubMed · Cited by 51
Cramér–Rao sensitivity limits for astronomical instruments: implications for interferometer design
Zmuidzinas, J. S. (2003) · Journal of the Optical Society of America A · doi:10.1364/josaa.20.000218 · Cited by 50
First tomographic image of neutron capture rate in a BNCT facility
Minsky, D. M., Valda, A. A., Kreiner, A. J., Green, S., Wojnecki, C., & Ghani, Z. (2011) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2011.01.030 · Cited by 50
Yeo, K. L., Feller, A., Solanki, S. K., Couvidat, S., Danilovic, S., & Krivova, N. A. (2013) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201322502 · Cited by 50
Bousse, A., Bertolli, O., Atkinson, D., Arridge, S., Sebastien Ourselin, A., Hutton, B. F., & Thielemans, K. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2464156 · Cited by 50
Current Research into Applications of Tomography for Fusion Diagnostics
contributors, J., Mlynar, J., Craciunescu, T., Ferreira, D. R., Carvalho, P. J., Ficker, O., Grover, O., Imríšek, M., & Svoboda, J. (2018) · Journal of Fusion Energy · doi:10.1007/s10894-018-0178-x · Cited by 50
Schaart, D. R., Schramm, G., Nuyts, J. L., & Surti, S. (2021) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2021.3084539 · Cited by 50
Fully 4D image reconstruction by estimation of an input function and spectral coefficients
Reader, A. J., Matthews, J. C., Sureau, F. C., Comtat, C., Trébossen, R., & Buvat, I. (2007) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2007.4436834 · Cited by 50
Multiple line source array for SPECT transmission scans: simulation, phantom and patient studies.
Celler, A. M., Sitek, A., Stoub, E. W., Hawman, P. C., Harrop, R., & Lyster, D. (1998) · PubMed · Cited by 50
Numerical methods in tomography
Natterer, F. (1999) · Acta Numerica · doi:10.1017/s0962492900002907 · Cited by 50
Smith, A. M., Gullberg, G. T., & Christian, P. E. (1996) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(96)90005-7 · Cited by 50
A Model for Segmentation and Analysis of Noisy Images
Johnson, V. E. (1994) · Journal of the American Statistical Association · doi:10.1080/01621459.1994.10476464 · Cited by 50
Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography
Kudo, H., & Saito, T. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002169 · Cited by 50
Correction methods for missing data in sinograms of the HRRT PET scanner
de Jong, H. W. A. M., Boellaard, R., Knoess, C., Lenox, M., Michel, C. J., Casey, M. E., & Lammertsma, A. A. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817366 · Cited by 50
Sparsity regularization for image reconstruction with Poisson data
Lingenfelter, D. J., Fessler, J. A., & He, Z. J. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.816961 · Cited by 49
Févotte, C., & Ozerov, A. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23126-1_8 · Cited by 49
Accuracy of 3-Dimensional Reconstruction Algorithms for the High-Resolution Research Tomograph
van Velden, F. H. P., Kloet, R. W., van Berckel, B. N. M., Lammertsma, A. A., & Boellaard, R. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.052985 · Cited by 49
Computed tomographic beam-hardening artefacts: mathematical characterization and analysis
Park, H. S., Chung, Y. E., & Seo, J. K. (2015) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2014.0388 · Cited by 49
Higher-order total variation approaches and generalisations
Bredies, K., & Höller, M. (2020) · Inverse Problems · doi:10.1088/1361-6420/ab8f80 · Cited by 49
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Venkataraman, R., Villani, M., Croft, S., McClay, P., McElroy, R., Kane, S., Mueller, W. F., & Estep, R. J. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.04.125 · Cited by 49
The past, present, and future of image and multidimensional signal processing
Chen, T. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.664673 · Cited by 49
Manglos, S. H. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/3/004 · Cited by 49
Measuring neutron spectra in radiotherapy using the nested neutron spectrometer
Maglieri, R., Licea, A., Evans, M. D., Seuntjens, J. P., & Kildea, J. (2015) · Medical Physics · doi:10.1118/1.4931963 · Cited by 48
Inverse problems in biomedical imaging: modeling and methods of solution
Bertero, M., & Piana, M. (2007) · Springer eBooks · doi:10.1007/88-470-0396-2_1 · Cited by 48
Gal, M., Reading, A. M., Ellingsen, S. P., Koper, K. D., Burlacu, R., & Gibbons, S. J. (2016) · Geophysical Journal International · doi:10.1093/gji/ggw150 · Cited by 48
Li, L., Zhang, S., Li, R., & Chen, Z. (2017) · Optical Engineering · doi:10.1117/1.oe.56.4.043106 · Cited by 48
Abbott, B., Case, J. A., Dorbala, S., Einstein, A. J., Galt, J. R., Pagnanelli, R., Bullock-Palmer, R. P., Soman, P., & Wells, R. G. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1348-y · Cited by 48
Double-bunch unfolding methods for the Back-n white neutron source at CSNS
Han, Y., Wang, T. F., Li, Y., Ruan, X., Ren, J., Chen, Y., Li, Q., Wen, J., Tang, J., An, Q., et al. (2020) · Journal of Instrumentation · doi:10.1088/1748-0221/15/03/p03026 · Cited by 48
Visualizing Privacy-Utility Trade-Offs in Differentially Private Data Releases
Nanayakkara, P., Bater, J., He, X. Q., Hullman, J. R., & Rogers, J. (2022) · Proceedings on Privacy Enhancing Technologies · doi:10.2478/popets-2022-0058 · Cited by 63
Resolution reconsidered—Conventional approaches and an alternative
van den Bos, A., & den Dekker, A. J. (2001) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(01)80114-2 · Cited by 48
Global and local priors, and the location of lesions using gamma-camera imagery
Aykroyd, R. G., & Green, P. J. (1991) · Philosophical Transactions of the Royal Society of London Series A Physical and Engineering Sciences · doi:10.1098/rsta.1991.0128 · Cited by 48
Núñez, J., & Llacer, J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.56340 · Cited by 48
Reader, A. J., Ally, S., Bakatselos, F., Manavaki, R., Walledge, R. J., Jeavons, A. P., Julyan, P. J., Zhao, S., Hastings, D. L., & Zweit, J. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2001.1009185 · Cited by 48
Iterative Reconstruction Methods
Hutton, B. F., Nuyts, J. L., & Zaidi, H. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_4 · Cited by 47
Direct 4-D PET List Mode Parametric Reconstruction With a Novel EM Algorithm
Yan, J., Planeta‐Wilson, B., & Carson, R. E. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2212451 · Cited by 47
Radiation dose reduction in medical x‐ray CT via Fourier‐based iterative reconstruction
Fahimian, B., Zhao, Y., Huang, Z., Fung, R., Mao, Y. L., Zhu, C., Khatonabadi, M., DeMarco, J. J., Osher, S., McNitt‐Gray, M. F., et al. (2013) · Medical Physics · doi:10.1118/1.4791644 · Cited by 47
Practical considerations for image-based PSF and blobs reconstruction in PET
Stute, S., & Comtat, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/3849 · Cited by 46
Advanced Processing Sequence for 3-D THz Imaging
Balacey, H., Recur, B., Perraud, J.-B., Sleiman, J. B., Guillet, J.-P., & Mounaix, P. (2016) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2016.2519263 · Cited by 47
Technical and instrumentational foundations of PET/MRI
Rausch, I., Quick, H. H., Cal-González, J., Sattler, B., Boellaard, R., & Beyer, T. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2017.04.004 · Cited by 47
Abbott, B., Case, J. A., Dorbala, S., Einstein, A. J., Galt, J. R., Pagnanelli, R., Bullock-Palmer, R. P., Soman, P., & Wells, R. G. (2018) · Circulation Cardiovascular Imaging · doi:10.1161/hci.0000000000000020 · Cited by 47
3D Compton image reconstruction method for whole gamma imaging
Tashima, H., Yoshida, E., Wakizaka, H., Takahashi, M., Nagatsu, K., Tsuji, A. B., Kamada, K., Parodi, K., & Yamaya, T. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abb92e · Cited by 47
Teimoorisichani, M., Panin, V., Rothfuß, H., Sari, H., Rominger, A., & Conti, M. (2021) · Medical Physics · doi:10.1002/mp.15376 · Cited by 47
Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation.
Kadrmas, D. J., Jaszczak, R. J., McCormick, J. W., & Coleman, R. E. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/6/009 · Cited by 47
Holmes, T. J. (1989) · Journal of the Optical Society of America A · doi:10.1364/josaa.6.001006 · Cited by 47
Boren, E. L., Delbeke, D., Patton, J. A., & Sandler, M. P. (1999) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050401 · Cited by 47
Alternating Minimization as Sequential Unconstrained Minimization: A Survey
Byrne, C. L. (2012) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-012-0134-2 · Cited by 46
Relative Extents of Preformation and Neoformation in Tree Shoots: Analysis by a Deconvolution Method
Guédon, Y., Puntieri, J. G., Sabatier, S. A., & Barthélémy, D. (2006) · Annals of Botany · doi:10.1093/aob/mcl164 · Cited by 46
Tanaka, E., & Kudo, H. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/10/009 · Cited by 46
Single Reporter for Targeted Multimodal in Vivo Imaging
Niers, J. M., Chen, J. W., Lewandrowski, G. K., Kerami, M., Garanger, É., Wojtkiewicz, G. R., Waterman, P. R., Keliher, E. J., Weissleder, R., & Tannous, B. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja209868g · Cited by 46
Toward 10 meV Electron Energy-Loss Spectroscopy Resolution for Plasmonics
Bellido, E. P., Rossouw, D., & Botton, G. A. (2014) · Microscopy and Microanalysis · doi:10.1017/s1431927614000609 · Cited by 46
Online blind deconvolution for astronomical imaging
Stefan Harmeling, B., Hirsch, M., Sra, S., & Scholkopf, B. (2009) · IEEE International Conference on Computational Photography (ICCP) · doi:10.1109/iccphot.2009.5559014 · Cited by 46
ter Voert, E. E. G. W., Muehlematter, U. J., Delso, G., Pizzuto, D. A., Müller, J., Nagel, H. W., & Burger, I. A. (2018) · EJNMMI Research · doi:10.1186/s13550-018-0414-4 · Cited by 46
Comparing maximum likelihood estimation and constrained Tikhonov-Miller restoration
van Kempen, G. M. P., van der Voort, H. T. M., Bauman, J. G. J., & Strasters, K. C. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.482846 · Cited by 46
Selivanov, V. V., Lapointe, D., Bentourkia, M., & Lecomte, R. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.940180 · Cited by 46
Implementation of an accelerated iterative algorithm for cone-beam SPECT
Li, J., Jaszczak, R. J., Greer, K. L., & Coleman, R. E. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/025 · Cited by 46
Geometrical and Monte Carlo projectors in 3D PET reconstruction
Aguiar, P., Rafecas, M., Ortuño, J. E., Kontaxakis, G., Santos, A., Pavı́a, J., & Ros, D. (2010) · Medical Physics · doi:10.1118/1.3501884 · Cited by 45
Superiorization of the ML-EM Algorithm
Garduño, E., & Herman, G. T. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2283529 · Cited by 45
A Novel Sparsity Reconstruction Method from Poisson Data for 3D Bioluminescence Tomography
Zhang, X., Lu, Y., & Chan, T. F.-C. (2011) · Journal of Scientific Computing · doi:10.1007/s10915-011-9533-z · Cited by 45
Roth, C., Degenstein, D. A., Bourassa, A., & Llewellyn, E. J. (2007) · Canadian Journal of Physics · doi:10.1139/p07-130 · Cited by 45
Incorporating Anatomical Side Information Into PET Reconstruction Using Nonlocal Regularization
Nguyen, V.-G., & Lee, S. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2265881 · Cited by 45
Quantitative Statistical Methods for Image Quality Assessment
Dutta, J., Ahn, S., & Li, Q. (2013) · Theranostics · doi:10.7150/thno.6815 · Cited by 45
Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging
Rahmim, A., Tang, J., & Zaidi, H. (2012) · PET Clinics · doi:10.1016/j.cpet.2012.10.005 · Cited by 44
The expectation-maximization algorithm for ill-posed integral equations: a convergence analysis
Resmerita, E., Engl, H. W., & Iusem, A. N. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/6/019 · Cited by 45
Blind deconvolution of fluorescence micrographs by maximum-likelihood estimation
Krishnamurthi, V., Liu, Y.-H., Bhattacharyya, S., Turner, J. N., & Holmes, T. J. (1995) · Applied Optics · doi:10.1364/ao.34.006633 · Cited by 45
Iterative reconstruction method for light emitting sources based on the diffusion equation
Slavine, N., Lewis, M. A., Richer, E., & Antich, P. P. (2005) · Medical Physics · doi:10.1118/1.2138007 · Cited by 45
PET regularization by envelope guided conjugate gradients
Kaufman, L., & Neumaier, A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500147 · Cited by 45
Holte, S., Schmidlin, P., Linden, A., Rosenqvist, G., & Eriksson, L. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106689 · Cited by 45
Preliminary resolution performance of the prototype system for a 4-Layer DOI-PET scanner: jPET-D4
Yamaya, T., Hagiwara, N., Obi, T., Tsuda, T., Kitamura, K., Hasegawa, T., Haneishi, H., Inadama, N., Yoshida, E., & Murayama, H. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.871901 · Cited by 45
Alternating Minimization Algorithms: From Blahut-Arimoto to Expectation-Maximization
O’Sullivan, J. A. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5121-8_13 · Cited by 45
Tang, H. R., Brown, J. K., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775578 · Cited by 45
Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice
Wu, M. C., Hasegawa, B. H., & Dae, M. W. (2002) · Medical Physics · doi:10.1118/1.1521939 · Cited by 45
Chi, Z., Du, Y., Huang, W., & Tang, C. (2020) · Journal of Synchrotron Radiation · doi:10.1107/s1600577520003574 · Cited by 44
Fast and memory‐efficient Monte Carlo‐based image reconstruction for whole‐body PET
Zhang, L., Staelens, S. G., Holen, R. V., Beenhouwer, J. D., Verhaeghe, J. A. J., Kawrakow, I., & Vandenberghe, S. (2010) · Medical Physics · doi:10.1118/1.3455287 · Cited by 44
A Variational Framework for Region-Based Segmentation Incorporating Physical Noise Models
Sawatzky, A., Tenbrinck, D., Jiang, X., & Burger, M. (2013) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-013-0419-6 · Cited by 44
Investigation of optimization-based reconstruction with an image-total-variation constraint in PET
Zhang, Z., Ye, J., Chen, B., Perkins, A. E., Rose, S., Sidky, E. Y., Kao, C.-M., Xia, D., Tung, C., & Pan, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/16/6055 · Cited by 44
Deep reconstruction model for dynamic PET images
Cui, J., Liu, X., Wang, Y., & Liu, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0184667 · Cited by 44
Wavelets in Medical Image Processing: Denoising, Segmentation, and Registration
Jin, Y., Angelini, E. D., & Laine, A. F. (2005) · Springer eBooks · doi:10.1007/0-306-48551-6_6 · Cited by 44
Accelerated list-mode EM algorithm
Reader, A. J., Manavaki, R., Zhao, S., Julyan, P. J., Hastings, D. L., & Zweit, J. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.998679 · Cited by 44
Bettinardi, V., Pagani, E., Gilardi, M. C., Sakari Alenius, B., Thielemans, K., Teräs, M., & Fazio, F. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100651 · Cited by 44
Schmitt, D., Karuta, B., Carrier, C., & Lecomte, R. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.3923 · Cited by 44
Imaging by Injection of Accelerated Radioactive Particle Beams
Llacer, J., Chatterjee, A., Alpen, E. L., Saunders, W., Andreae, S. W., & Jackson, H. C. (1984) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1984.4307660 · Cited by 44
Brix, G., Bellemann, M. E., Haberkorn, U., Gerlach, L., & Lorenz, W. J. (1996) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(96)00122-9 · Cited by 44
Rapid emission tomography reconstruction
Chidlow, K., & Möller, T. B. (2003) · doi:10.1145/827051.827053 · Cited by 44
Multi-Objective Evolutionary Algorithm for PET Image Reconstruction: Concept
Abouhawwash, M., & Alessio, A. M. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3073243 · Cited by 43
Radiation Dose Optimization and Thoracic Computed Tomography
Singh, S., Kalra, M. K., Khawaja, R. D. A., Padole, A. M., Pourjabbar, S., Lira, D., Shepard, J.-A. O., & Digumarthy, S. R. (2013) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2013.08.004 · Cited by 43
Chan, C., Fulton, R., Feng, D. D., & Meikle, S. R. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/24/009 · Cited by 43
Firstin situTOF-PET study using digital photon counters for proton range verification
Lopes, P. C., Bauer, J., Salomon, A., Rinaldi, I., Tabacchini, V., Tessonnier, T., Crespo, P., Parodi, K., & Schaart, D. R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/16/6203 · Cited by 43
Faster PET reconstruction with non-smooth priors by randomization and preconditioning
Ehrhardt, M. J., Markiewicz, P. J., & Schönlieb, C. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab3d07 · Cited by 43
Positron Emission Tomography: Its 65 years
Guerra, A. D., Belcari, N., & Bisogni, M. G. (2016) · CINECA IRIS Institutial research information system (University of Pisa) · doi:10.1393/ncr/i2016-10122-6 · Cited by 42
Reimer, T., Nepote, M. S., & Pistorius, S. (2020) · Diagnostics · doi:10.3390/diagnostics10060411 · Cited by 43
The image quality of FBP and MLEM reconstruction
Wieczorek, H. K. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/11/012 · Cited by 43
Koch, W., Hamann, C., Welsch, J., Pöpperl, G., Radau, P. E., & Tatsch, K. (2005) · PubMed · Cited by 45
Hero, A. O., Piramuthu, R., Fessler, J. A., & Titus, S. R. (1999) · IEEE Transactions on Information Theory · doi:10.1109/18.761333 · Cited by 43
Yamaya, T., Hagiwara, N., Obi, T., Yamaguchi, M., Kita, K., Ohyama, N., Kitamura, K., Hasegawa, T., Haneishi, H., & Murayama, H. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817307 · Cited by 43
SPECTnet: a deep learning neural network for SPECT image reconstruction
Shao, W., Rowe, S. P., & Du, Y. (2021) · Annals of Translational Medicine · doi:10.21037/atm-20-3345 · Cited by 42
Barbee, D. L., Flynn, R. T., Holden, J. E., Nickles, R. J., & Jeraj, R. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/013 · Cited by 42
A PET detector prototype based on digital SiPMs and GAGG scintillators
Schneider, F. R., Shimazoe, K., Somlai-Schweiger, I., & Ziegler, S. I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/1667 · Cited by 42
Tan, Y.-Y., Matsui, H., Ishiguro, N., Uruga, T., Nguyen, D., Sekizawa, O., Sakata, T., Maejima, N., Higashi, K., Dam, H., et al. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b05005 · Cited by 42
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review