The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 101–200 of 1,000
Dynamics of the nuclear lamina as monitored by GFP-tagged A-type lamins
Broers, J. L. V., Machiels, B. M., van Eys, G. J. J. M., Kuijpers, H. J. H., Manders, E. M. M., DRIEL, R. V., & Ramaekers, F. C. S. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.20.3463 · Cited by 246
Convergence studies on iterative algorithms for image reconstruction
Jiang, M. F., & Wang, G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812253 · Cited by 244
Bayesian image reconstruction for emission tomography based on median root prior
Sakari Alenius, B., & Ruotsalainen, U. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf01728761 · Cited by 243
Barrett, H. H., White, T. A., & Parra, L. C. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002914 · Cited by 241
PET Image Reconstruction Using Kernel Method
Wang, G., & Qi, J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2343916 · Cited by 240
Advances in technical aspects of myocardial perfusion SPECT imaging
Slomka, P. J., Patton, J. A., Berman, D. S., & Germano, G. (2009) · Journal of Nuclear Cardiology · doi:10.1007/s12350-009-9052-6 · Cited by 240
Statistical Image Reconstruction Methods for Transmission Tomography
Fessler, J. A. (2010) · SPIE eBooks · doi:10.1117/3.831079.ch1 · Cited by 240
Iterative image reconstruction algorithms based on cross-entropy minimization
Byrne, C. L. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.210869 · Cited by 240
A motion-incorporated reconstruction method for gated PET studies
Qiao, F., Pan, T., Clark, J. W., & Mawlawi, O. R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/012 · Cited by 239
Effert, P. J., Bares, R., Handt, S., Wolff, J. M., Büll, U., & Jakse, G. (1996) · The Journal of Urology · doi:10.1016/s0022-5347(01)66366-3 · Cited by 239
Merlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipović, M., Lamare, F., & Visvikis, D. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aadac1 · Cited by 238
Implementation of simultaneous attenuation and detector response correction in SPECT
Tsui, B. M. W., Hu, H.-B., Gilland, D. R., & Gullberg, G. T. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12831 · Cited by 238
Flamen, P., Stroobants, S. G., Cutsem, E. V., Dupont, P. J., Bormans, G. M., Vadder, N. D., PENNINCKX, F. M., Hoe, L. V., & Mortelmans, L. A. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.3.894 · Cited by 238
Bayesian reconstruction and use of anatomical a priori information for emission tomography
Bowsher, J. E., Johnson, V. E., Turkington, T. G., Jaszczak, R. J., Floyd, C. E., & Coleman, R. E. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538945 · Cited by 238
An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT
Daube-Witherspoon, M. E., & Muehllehner, G. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307748 · Cited by 237
Rührnschopf, E., & Klingenbeck, K. (2011) · Medical Physics · doi:10.1118/1.3599033 · Cited by 233
High-Speed Myocardial Perfusion Imaging
Sharir, T., Ben‐Haim, S., Merzon, K., Prochorov, V., Dickman, D., Ben‐Haim, S. A., & Berman, D. S. (2008) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2007.12.004 · Cited by 233
One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
Reader, A. J., Ally, S., Bakatselos, F., Manavaki, R., Walledge, R. J., Jeavons, A. P., Julyan, P. J., Zhao, S., Hastings, D. L., & Zweit, J. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039550 · Cited by 232
Deep Learning for PET Image Reconstruction
Reader, A. J., Corda-D’Incan, G., Mehranian, A., da Costa-Luis, C. O., Ellis, S., & Schnabel, J. A. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3014786 · Cited by 255
Pontana, F., Duhamel, A., Pagniez, J., Flohr, T. G., Faivre, J., Hachulla, A.-L., Rémy, J., & Rémy-Jardin, M. (2010) · European Radiology · doi:10.1007/s00330-010-1991-4 · Cited by 229
Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
Zeng, G. L., & Gullberg, G. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870265 · Cited by 228
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 232
Schulte, R. W., Bashkirov, V. A., Li, T., Liang, Z., Mueller, K. D., Heimann, J., Johnson, L. R., Keeney, B., Sadrozinski, H. F.-W., Seiden, A., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829392 · Cited by 224
Spaepen, K., Stroobants, S. G., Dupont, P. J., Vandenberghe, P., Maertens, J. A., Bormans, G. M., Thomas, J., Balzarini, J. M., Wolf‐Peeters, C. D., Mortelmans, L. A., et al. (2003) · Blood · doi:10.1182/blood-2002-12-3842 · Cited by 224
Deblurring subject to nonnegativity constraints
Snyder, D. L., Schulz, T. J., & O’Sullivan, J. A. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.134477 · Cited by 224
Auxiliary Variable Methods for Markov Chain Monte Carlo with Applications
Higdon, D. (1998) · Journal of the American Statistical Association · doi:10.1080/01621459.1998.10473712 · Cited by 222
Koehne, G., Doubrovin, M., Doubrovina, E. S., ZANZONICO, P. B., Gallardo, H. F., Ivanova, A. E., Balatoni, J., Teruya‐Feldstein, J., Heller, G., May, C., et al. (2003) · Nature Biotechnology · doi:10.1038/nbt805 · Cited by 221
Review and current status of SPECT scatter correction
Hutton, B. F., Buvat, I., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/r01 · Cited by 217
Random fields and inverse problems in imaging
Geman, D. (1990) · Lecture notes in mathematics · doi:10.1007/bfb0103042 · Cited by 216
Statistical approaches in quantitative positron emission tomography
Leahy, R. M., & Qi, J. (2000) · Statistics and Computing · doi:10.1023/a:1008946426658 · Cited by 215
Bayesian reconstruction of PET images: methodology and performance analysis
Mumcuoglu, E. U., Leahy, R. M., & Cherry, S. R. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/9/015 · Cited by 214
Generalized Alpha-Beta Divergences and Their Application to Robust Nonnegative Matrix Factorization
Cichocki, A. S., Cruces, S., & Амари, Ш.-И. (2011) · Entropy · doi:10.3390/e13010134 · Cited by 213
Nuyts, J. L., Beque, D., Dupont, P. J., & Mortelmans, L. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.998681 · Cited by 211
Model‐based image reconstruction for four‐dimensional PET
Li, T., Thorndyke, B., Schreibmann, E., Yang, Y., & Xing, L. (2006) · Medical Physics · doi:10.1118/1.2192581 · Cited by 210
Deblurring Shaken and Partially Saturated Images
Whyte, O., Šivic, J., & Zisserman, A. (2014) · International Journal of Computer Vision · doi:10.1007/s11263-014-0727-3 · Cited by 210
Ueta, T., Meixner, M. M., & Bobrowsky, M. (2000) · The Astrophysical Journal · doi:10.1086/308208 · Cited by 210
Modelling white matter with spherical deconvolution: How and why?
Dell’Acqua, F., & Tournier, J. (2018) · NMR in Biomedicine · doi:10.1002/nbm.3945 · Cited by 223
Hong, I. K., Chung, S. T., Kim, H., Kim, Y. B., Son, Y., & Cho, Z. H. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892644 · Cited by 207
Maximum likelihood identification of neural point process systems
Chornoboy, E. S., Schramm, L. P., & Karr, A. F. (1988) · Biological Cybernetics · doi:10.1007/bf00332915 · Cited by 205
Blind deconvolution of quantum-limited incoherent imagery: maximum-likelihood approach
Holmes, T. J. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.001052 · Cited by 205
Limited-data computed tomography algorithms for the physical sciences
Verhoeven, D. D. (1993) · Applied Optics · doi:10.1364/ao.32.003736 · Cited by 202
Transmission scanning in emission tomography
Bailey, D. L. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050282 · Cited by 202
Mathematical concepts of optical superresolution
Lindberg, J. (2012) · Journal of Optics · doi:10.1088/2040-8978/14/8/083001 · Cited by 199
Overview of methods for image reconstruction from projections in emission computed tomography
Lewitt, R. M., & Matej, S. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817882 · Cited by 200
Seo, Y., Marí, C., & Hasegawa, B. (2008) · Seminars in nuclear medicine · doi:10.1053/j.semnuclmed.2008.01.001 · Cited by 185
Hatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., Bernardi, E. D., Lü, W., Das, S. K., Geets, X., Grégoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 208
Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
Beekman, F. J., de Jong, H. W. A. M., & van Geloven, S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803130 · Cited by 197
Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
Bailey, D. L., & Willowson, K. P. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2542-4 · Cited by 196
Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT
Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336940 · Cited by 196
Boellaard, R., van Lingen, A., & Lammertsma, A. A. (2001) · PubMed · Cited by 195
Recovering Tree Heights from Airborne Laser Scanner Data
Magnussen, S., Eggermont, P. P. B., & LaRiccia, V. N. (1999) · Forest Science · doi:10.1093/forestscience/45.3.407 · Cited by 193
A Fast Algorithm to Calculate the Exact Radiological Path through a Pixel or Voxel Space
Jacobs, F., Sundermann, E., Sutter, B. D., Christiaens, M., & Lemahieu, I. A. (1998) · Journal of Computing and Information Technology · Cited by 192
EM algorithm system modeling by image-space techniques for PET reconstruction
Reader, A. J., Julyan, P. J., Williams, H. A., Hastings, D. L., & Zweit, J. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817327 · Cited by 191
FDG-PET for preoperative staging of bladder cancer
DRIESKENS, O., Oyen, R., Poppel, H. V., Vankan, Y., Flamen, P., & Mortelmans, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1886-9 · Cited by 190
Fast accurate iterative reconstruction for low-statistics positron volume imaging
Reader, A. J., Erlandsson, K., Flower, M. A., & Ott, R. J. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/012 · Cited by 190
Block-iterative methods for image reconstruction from projections
Byrne, C. L. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.499919 · Cited by 188
Simultaneous reconstruction of activity and attenuation in Time-of-Flight PET
Rezaei, A., Nuyts, J. L., Defrise, M., Bal, G., Michel, C. J., Conti, M., & Watson, C. C. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153883 · Cited by 185
Efficient and Interpretable Deep Blind Image Deblurring Via Algorithm Unrolling
Li, Y., Tofighi, M., Geng, J., Monga, V., & Eldar, Y. C. (2020) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2020.2964202 · Cited by 213
Fast EM-like methods for maximum "a posteriori" estimates in emission tomography
Pierro, A. R. D., & Yamagishi, M. E. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921477 · Cited by 182
PET: Physics, Instrumentation, and Scanners
Cherry, S. R., & Dahlbom, M. L. (2006) · Springer eBooks · doi:10.1007/0-387-34946-4_1 · Cited by 181
Maximum likelihood, least squares, and penalized least squares for PET
Kaufman, L. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232249 · Cited by 180
Statistical Deconvolution for Superresolution Fluorescence Microscopy
Mukamel, E. A., Babcock, H. P., & Zhuang, X. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.03.070 · Cited by 177
Improving energy resolution of EELS spectra: an alternative to the monochromator solution
Gloter, A., Douiri, A., Tencé, M., & Colliex, C. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(03)00103-7 · Cited by 174
Advances in time-of-flight PET
Surti, S., & Karp, J. S. (2016) · Physica Medica · doi:10.1016/j.ejmp.2015.12.007 · Cited by 173
An attenuated projector-backprojector for iterative SPECT reconstruction
Gullberg, G. T., Huesman, R. H., MALKO, J. A., Pelc, N. J., & Budinger, T. F. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/8/004 · Cited by 173
List-mode maximum likelihood reconstruction of Compton scatter camera images in nuclear medicine
Wilderman, S. J., Clinthorne, N. H., Fessler, J. A., & Rogers, W. L. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773871 · Cited by 171
Augmented Lagrangian method for total variation restoration with non-quadratic fidelity
Wu, C., Zhang, J., & Tai, X. (2011) · Inverse Problems and Imaging · doi:10.3934/ipi.2011.5.237 · Cited by 171
Ordered-subset simultaneous algebraic reconstruction techniques (OS-SART)
Wang, G., & Jiang, M. F. (2004) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2004-00110 · Cited by 170
X-Ray Luminescence Computed Tomography via Selective Excitation: A Feasibility Study
Pratx, G., Carpenter, C. M., Sun, C., & Xing, L. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2055883 · Cited by 170
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Kalra, M. K., Woisetschläger, M., Dahlström, N., Singh, S., Lindblom, M., Choy, G., Quick, P., Schmidt, B. T., Sedlmair, M., Blake, M. A., et al. (2012) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31825586c0 · Cited by 168
Spaepen, K., Stroobants, S. G., Dupont, P. J., Thomas, J., Vandenberghe, P., Balzarini, J. M., Wolf‐Peeters, C. D., Mortelmans, L. A., & Verhoef, G. E. G. (2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.03169.x · Cited by 168
A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data
Qi, J., & Leahy, R. M. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.768839 · Cited by 167
On the relation between the ISRA and the EM algorithm for positron emission tomography
Pierro, A. R. D. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232263 · Cited by 167
OmniFold: A Method to Simultaneously Unfold All Observables
Andreassen, A., Komiske, P., Metodiev, E. M., Nachman, B. P., & Thaler, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.182001 · Cited by 164
First experimental results of time-of-flight reconstruction on an LSO PET scanner
Conti, M., Bendriem, B., Casey, M., Chen, M., Kehren, F., Michel, C. J., & Panin, V. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/19/006 · Cited by 164
Vansteenkiste, J., Stroobants, S. G., Dupont, P. J., Leyn, P. R. D., Wever, W. F. D., Verbeken, E. K., Nuyts, J. L., Maes, F., & Bogaert, J. G. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050327 · Cited by 163
Digital Image Reconstruction: Deblurring and Denoising
Puetter, R. C., Gosnell, T. R., & Yahil, A. (2005) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.astro.43.112904.104850 · Cited by 163
The importance and implementation of accurate 3D compensation methods for quantitative SPECT
Tsui, B. M. W., Frey, E. C., Zhao, X., Lalush, D. S., Johnston, R. E., & McCartney, W. H. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/015 · Cited by 161
Compensation for readout noise in CCD images
Snyder, D. L., Helstrom, C. W., Lanterman, A. D., White, R. L., & Faisal, M. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.000272 · Cited by 161
Borges‐Neto, S., Pagnanelli, R., Shaw, L. K., Honeycutt, E. F., Shwartz, S. C., Adams, G. L., & Coleman, E. R. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.04.022 · Cited by 160
ML parameter estimation for Markov random fields with applications to Bayesian tomography
Saquib, S. S., Bouman, C. A., & Sauer, K. D. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.701163 · Cited by 160
Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging
Vunckx, K., Atre, A., Baete, K., Reilhac, A., Deroose, C. M., Laere, K. V., & Nuyts, J. L. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2173766 · Cited by 159
The Ordered Subsets Mirror Descent Optimization Method with Applications to Tomography
Ben‐Tal, A., Margalit, T., & Nemirovski, A. S. (2001) · SIAM Journal on Optimization · doi:10.1137/s1052623499354564 · Cited by 157
Accelerating the EMML algorithm and related iterative algorithms by rescaled block-iterative methods
Byrne, C. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.650854 · Cited by 157
Recovery correction for quantitation in emission tomography: a feasibility study
Geworski, L., Knoop, B. O., de Cabrejas, M. L., Knapp, W. H., & Munz, D. L. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050022 · Cited by 156
Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique
Formiconi, A. R., Pupi, A., & Passeri, A. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/1/007 · Cited by 156
A review of snapshot multidimensional optical imaging: Measuring photon tags in parallel
Gao, L. S., & Wang, L. V. (2015) · Physics Reports · doi:10.1016/j.physrep.2015.12.004 · Cited by 155
Iterative approaches to dose optimization in tomotherapy
Shepard, D. M., Olivera, G., Reckwerdt, P. J., & Mackie, T. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/1/306 · Cited by 155
Lewitt, R. M., & Muehllehner, G. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307734 · Cited by 155
Ahn, S., Ross, S. G., Asma, E., Miao, J., Jin, X. H., Cheng, L., Wollenweber, S. D., & Manjeshwar, R. M. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/15/5733 · Cited by 154
Incorporation of anatomical MR data for improved functional imaging with PET
Leahy, R. M., & Yan, X. (2005) · Springer eBooks · doi:10.1007/bfb0033746 · Cited by 154
Characterization of pinhole SPECT acquisition geometry
Beque, D., Nuyts, J. L., Bormans, G. M., Suetens, P., & Dupont, P. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812258 · Cited by 154
Recent Advances in CT Image Reconstruction
Hsieh, J., Nett, B. E., Zhou, Y., Sauer, K. D., Thibault, J., & Bouman, C. A. (2013) · Current Radiology Reports · doi:10.1007/s40134-012-0003-7 · Cited by 153
A Robust Automated Measure of Average Antibody Staining in Immunohistochemistry Images
Choudhury, K. R., Yagle, K. J., Swanson, P. E., Krohn, K. A., & Rajendran, J. G. (2009) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.2009.953554 · Cited by 153
Applied Bayesian Modeling And Causal Inference From Incomplete-Data Perspectives
Gelman, A., & Xiaoli, M. (2014) · Cited by 152
Image restoration in astronomy: a Bayesian perspective
Molina, R., Núñez, J., Cortijo, F. J., & Javier Mateos, A. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.916318 · Cited by 150
Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Tsui, B. M. W., Zhao, X., Gregoriou, G. K., Lalush, D. S., Frey, E. C., Johnston, R. E., & McCartney, W. H. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.340655 · Cited by 147
Optimization of the acquisition geometry in digital tomosynthesis of the breast
Sechopoulos, I., & Ghetti, C. (2009) · Medical Physics · doi:10.1118/1.3090889 · Cited by 146
Inverse problems: From regularization to Bayesian inference
Daniela Calvetti, A., & Somersalo, E. (2018) · Wiley Interdisciplinary Reviews Computational Statistics · doi:10.1002/wics.1427 · Cited by 144
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›