The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 301–400 of 1,000
Reconstructing influenza incidence by deconvolution of daily mortality time series
Goldstein, E., Dushoff, J., Ma, J., Plotkin, J. B., Earn, D. J. D., & Lipsitch, M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902958106 · Cited by 94
Kobayashi, H., Mark, B. L., & Turin, W. (2012) · CERN Document Server (European Organization for Nuclear Research) · Cited by 104
Multi-ray-based system matrix generation for 3D PET reconstruction
Moehrs, S., Defrise, M., Belcari, N., Guerra, A. D., Bartoli, A., Fabbri, S., & Zanetti, G. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/23/018 · Cited by 102
Attenuation correction in emission tomography using the emission data—A review
Berker, Y., & Li, Y. (2016) · Medical Physics · doi:10.1118/1.4938264 · Cited by 101
Super‐resolution of images: Algorithms, principles, performance
Hunt, B. R. (1995) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.1850060403 · Cited by 101
EM algorithm reconstruction of particle size distributions from diffusion battery data
Maher, E. F., & Laird, N. M. (1985) · Journal of Aerosol Science · doi:10.1016/0021-8502(85)90007-2 · Cited by 100
Verstraeten, V. L. R. M. (2006) · Human Molecular Genetics · doi:10.1093/hmg/ddl172 · Cited by 100
Minimum cross-entropy reconstruction of PET images using prior anatomical information
Ardekani, B. A., Braun, M., Hutton, B. F., Kanno, I., & Iida, H. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/018 · Cited by 100
Lindström, E., Sundin, A., Trampal, C., Lindsjö, L., Ilan, E., Danfors, T., Antoni, G., Sörensen, J., & Lubberink, M. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200790 · Cited by 99
Postreconstruction Nonlocal Means Filtering of Whole-Body PET With an Anatomical Prior
Chan, C., Fulton, R., Barnett, R., Feng, D. D., & Meikle, S. R. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2292881 · Cited by 99
FIRST: Fast Iterative Reconstruction Software for (PET) tomography
Herraiz, J. L., España, S., Vaquero, J. J., Desco, M., & Udías, J. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/007 · Cited by 99
Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
Bateman, T. M., & Cullom, S. J. (2005) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2004.09.003 · Cited by 99
Pain, C. D., Egan, G. F., & Chen, Z. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05746-4 · Cited by 101
Investigation of X-ray Fluorescence Computed Tomography (XFCT) and K-Edge Imaging
Bazalova‐Carter, M., Kuang, Y., Pratx, G., & Xing, L. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2201165 · Cited by 98
EM algorithms without missing data
Becker, M. P., Yang, I., & Lange, K. L. (1997) · Statistical Methods in Medical Research · doi:10.1177/096228029700600104 · Cited by 97
Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
Kriekinge, S. D. V., Berman, D. S., & Germano, G. (1999) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(99)90022-3 · Cited by 99
Accuracy and Precision of Radioactivity Quantification in Nuclear Medicine Images
Frey, E. C., Humm, J. L., & Ljungberg, M. H. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.11.003 · Cited by 97
Zuo, J. (2000) · Microscopy Research and Technique · doi:10.1002/(sici)1097-0029(20000501)49:3 · Cited by 97
4-pi Compton imaging with single 3D position-sensitive CdZnTe detector
Xu, D., He, Z. J., Lehner, C. E., & Zhang, F. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.563905 · Cited by 97
Dual-Modality Imaging of Cancer with SPECT/CT
Hasegawa, B. H., Wong, K. H., Iwata, K., Barber, W. C., Hwang, A. B., Sakdinawat, A. E., Ramaswamy, M. R., Price, D. C., & Hawkins, R. A. (2002) · Technology in Cancer Research & Treatment · doi:10.1177/153303460200100605 · Cited by 97
Multiplicative iterative algorithms for convex programming
Eggermont, P. P. B. (1990) · Linear Algebra and its Applications · doi:10.1016/0024-3795(90)90204-p · Cited by 97
Joint Reconstruction of Image and Motion in Gated Positron Emission Tomography
Blume, M., Martínez-Möller, A., Keil, A., Navab, N., & Rafecas, M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053212 · Cited by 96
Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection
Gürsoy, D., Hong, Y. P., He, K. F., Hujsak, K. A., Yoo, S., Chen, S., Li, Y., Ge, M., Miller, L. M., Chu, Y. S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-12141-9 · Cited by 96
Deep learning-based PET image denoising and reconstruction: a review
Hashimoto, F., Onishi, Y., Ote, K., Tashima, H., Reader, A. J., & Yamaya, T. (2024) · Radiological Physics and Technology · doi:10.1007/s12194-024-00780-3 · Cited by 113
Liow, J.-S., & Strother, S. C. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108591 · Cited by 96
SPECT in the year 2000: basic principles.
Groch, M. W., & Erwin, W. D. (2000) · PubMed · Cited by 95
First Demonstration of Multiplexed X-Ray Fluorescence Computed Tomography (XFCT) Imaging
Kuang, Y., Pratx, G., Bazalova‐Carter, M., Meng, B., Qian, J., & Xing, L. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2223709 · Cited by 94
DPIR-Net: Direct PET Image Reconstruction Based on the Wasserstein Generative Adversarial Network
Hu, Z., Xue, H., Zhang, Q., Gao, J., Zhang, N., Zou, S., Teng, Y., Liu, X., Yang, Y., Liang, D., et al. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2995717 · Cited by 94
Artificial Intelligence-Based Image Enhancement in PET Imaging
Liu, J., Malekzadeh, M., Mirian, N., Song, T.-A., Liu, C., & Dutta, J. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.005 · Cited by 98
Acceleration of the direct reconstruction of linear parametric images using nested algorithms
Wang, G., & Qi, J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/016 · Cited by 94
X-ray fluorescent computer tomography with synchrotron radiation
Rust, G.-F., & Weigelt, J. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.659557 · Cited by 94
Maximum likelihood SPECT in clinical computation times using mesh-connected parallel computers
McCarthy, A. W., & Miller, M. I. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97593 · Cited by 94
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices
Korcyl, G., Hiesmayr, B. C., Jasinska, B., Kacprzak, K., Kajetanowicz, M., Kisielewska, D., Kowalski, P., Kozik, T., Krawczyk, N., Krzemień, W., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837741 · Cited by 93
Volumetric emission tomography for combustion processes
Grauer, S. J., Mohri, K., Yu, T., Liu, H., & Cai, W. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2022.101024 · Cited by 96
Williamson, J. F., Whiting, B. R., Benac, J., Murphy, R. J., Blaine, G. J., O’Sullivan, J. A., Politte, D. G., & Snyder, D. L. (2002) · Medical Physics · doi:10.1118/1.1509443 · Cited by 93
Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.
Riddell, C., Carson, R. E., Carrasquillo, J. A., Libutti, S. K., Danforth, D. N., Whatley, M. A., & Bacharach, S. L. (2001) · PubMed · Cited by 93
Joint estimation of image and deformation parameters in motion-corrected PET
Jacobson, M. W., & Fessler, J. A. (2004) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2003.1352599 · Cited by 93
A system for the 3D reconstruction of retracted-septa PET data using the EM algorithm
Johnson, C. A., Yan, Y., Carson, R. E., Martino, R. L., & Daube-Witherspoon, M. E. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467875 · Cited by 93
Sakari Alenius, B., Ruotsalainen, U., & Astola, J. T. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.737670 · Cited by 93
Maximum-Likelihood Reconstruction for Single-Photon Emission Computed-Tomography
Miller, M. I., Snyder, D. L., & Miller, T. R. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336939 · Cited by 93
Liang, Z., Jaszczak, R. J., & Greer, K. L. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34711 · Cited by 93
Human Positron Emission Tomography Neuroimaging
Hooker, J. M., & Carson, R. E. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121056 · Cited by 97
Development and Applications of Compton Camera—A Review
Parajuli, R. K., Sakai, M., Parajuli, R., & Tashiro, M. (2022) · Sensors · doi:10.3390/s22197374 · Cited by 92
Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86
Walrand, S., Jamar, F., Mathieu, I., Camps, J., Lonneux, M., Sibomana, M., Labar, D., Michel, C. J., & Pauwels, S. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1068-y · Cited by 92
A study of the liver-heart artifact in emission tomography.
Nuyts, J. L., Dupont, P. J., den Maegdenbergh, V. V., Vleugels, S., Suetens, P., & Mortelmans, L. (1995) · PubMed · Cited by 92
LOR-OSEM: statistical PET reconstruction from raw line-of-response histograms
Kadrmas, D. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/20/005 · Cited by 91
18-FDG PET scan in the staging of recurrent melanoma: additional value and therapeutic impact
Stas, M., Stroobants, S. G., Dupont, P. J., Gysen, M., Hoe, L. V., Garmyn, M., Mortelmans, L., & Wever, I. D. (2002) · Melanoma Research · doi:10.1097/00008390-200209000-00010 · Cited by 91
Algorithms for the analysis of β -decay total absorption spectra
Tain, J. L., & Cano-Ott, D. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.098 · Cited by 90
Nuyts, J. L., Michel, C. J., & Dupont, P. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.925290 · Cited by 90
Effect of surface heterogeneity on adsorption on solid surfaces
Charmas, B., & Leboda, R. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00432-5 · Cited by 89
Veklerov, E., Llacer, J., & Hoffman, E. J. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12795 · Cited by 89
Unsupervised deconvolution of sparse spike trains using stochastic approximation
Champagnat, F., Goussard, Y., & Idier, J. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.553473 · Cited by 89
Benvenuto, F., Camera, A., Theys, C., Ferrari, A., Lantéri, H., & Bertero, M. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/3/035016 · Cited by 89
Inverse problems with Poisson data: statistical regularization theory, applications and algorithms
Hohage, T., & Werner, F. (2016) · Inverse Problems · doi:10.1088/0266-5611/32/9/093001 · Cited by 94
Apparent water diffusion measurements in electrically stimulated neural tissue
Gulani, V., Iwamoto, G. A., & Lauterbur, P. C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2 · Cited by 22
Model-based respiratory motion compensation for emission tomography image reconstruction
Reyes, M., Malandain, G., Koulibaly, P. M., González‐Ballester, M. Á., & Darcourt, J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/016 · Cited by 88
Nicholson, G., & Contaldi, C. (2009) · Journal of Cosmology and Astroparticle Physics · doi:10.1088/1475-7516/2009/07/011 · Cited by 88
Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging
Abdoli, M., Dierckx, R., & Zaidi, H. (2012) · Medical Physics · doi:10.1118/1.4709599 · Cited by 88
Parametric image reconstruction using spectral analysis of PET projection data
Meikle, S. R., Matthews, J. C., Cunningham, V. J., Bailey, D. L., Livieratos, L., Jones, T., & Price, P. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/3/016 · Cited by 88
Hebert, T., Leahy, R. M., & Singh, M. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001305 · Cited by 88
Lu, F., Nguyen, A. T., Link, N., Molina, M., Davis, J. T., Chinazzi, M., Xiong, X., Vespignani, A., Lipsitch, M., & Santillana, M. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1008994 · Cited by 82
Silva, A. J. D., Tang, H. R., Wong, K. H., Wu, M. C., Dae, M. W., & Hasegawa, B. H. (2001) · PubMed · Cited by 87
Noise characterization of block-iterative reconstruction algorithms. I. Theory
Soares, E. J., Byrne, C. L., & Glick, S. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.848178 · Cited by 87
Inverse radiation treatment planning using the Dynamically Penalized Likelihood method
Llacer, J. (1997) · Medical Physics · doi:10.1118/1.597961 · Cited by 87
Nonnegative least-squares image deblurring: improved gradient projection approaches
Benvenuto, F., Zanella, R., Zanni, L., & Bertero, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/26/2/025004 · Cited by 86
On the Convergence of Primal–Dual Hybrid Gradient Algorithms for Total Variation Image Restoration
Bonettini, S., & Ruggiero, V. (2012) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-011-0324-9 · Cited by 86
Superiorization: An optimization heuristic for medical physics
Herman, G. T., Garduño, E., Davidi, R., & Censor, Y. (2012) · Medical Physics · doi:10.1118/1.4745566 · Cited by 86
A survey of approaches for direct parametric image reconstruction in emission tomography
Tsoumpas, C., Turkheimer, F., & Thielemans, K. (2008) · Medical Physics · doi:10.1118/1.2966349 · Cited by 86
Simulation-based evaluation of OSEM iterative reconstruction methods in dynamic brain PET studies
Reilhac, A., Tomeï, S., Buvat, I., Michel, C. J., Keheren, F., & Costes, N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.038 · Cited by 86
Mumcuoglu, E. U., Leahy, R. M., Cherry, S. R., & Hoffman, E. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.587924 · Cited by 86
Bowsher, J. E., & Floyd, C. E. (1991) · PubMed · Cited by 86
Coupling Image Restoration and Segmentation: A Generalized Linear Model/Bregman Perspective
Paul, G., Cardinale, J., & Sbalzarini, I. F. (2013) · International Journal of Computer Vision · doi:10.1007/s11263-013-0615-2 · Cited by 85
High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study
Ilisie, V., Moliner, L., Oliver, S., Sánchez, F., González, A. J., Seimetz, M., Rodríguez-Álvarez, M. J., & Benlloch, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-54934-0 · Cited by 85
Schöder, H. M., Erdi, Y. E., Chao, K., Gönen, M., Larson, S. M., & YEUNG, H. W. D. (2004) · PubMed · Cited by 85
Jones, B. L., Manohar, N., Reynoso, F. J., Karellas, A., & Cho, S. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/n457 · Cited by 85
An EM algorithm for estimating SPECT emission and transmission parameters from emission data only
Król, A., Bowsher, J. E., Manglos, S. H., Feiglin, D., Tornai, M. P., & Thomas, F. D. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.918472 · Cited by 85
Tomographic reconstruction using an adaptive tetrahedral mesh defined by a point cloud
Sitek, A., Huesman, R. H., & Gullberg, G. T. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879319 · Cited by 85
Recent developments in iterative image reconstruction for PET and SPECT [Editorial]
Leahy, R. M., & Byrne, C. L. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2000.848177 · Cited by 85
Rangarajan, A., Hsiao, I., & Gindi, G. R. (2000) · Journal of Mathematical Imaging and Vision · doi:10.1023/a:1008314015446 · Cited by 84
Stochastic tomography and its applications in 3D imaging of mixing fluids
Gregson, J., Krimerman, M., Hullin, M. B., & Heidrich, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185548 · Cited by 84
Blind Image Deconvolution Using Machine Learning for Three-Dimensional Microscopy
Kenig, T., Kam, Z., & Arie Feuer, B. (2010) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.45 · Cited by 84
Kamphuis, C., Beekman, F. J., van Rijk, P. P., & Viergever, M. A. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050188 · Cited by 84
Iterative reconstruction for coronary CT angiography: finding its way
Leipsic, J. A., Heilbron, B. G., & Hague, C. J. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-011-9832-3 · Cited by 83
Jones, B. L., & Cho, S. H. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/12/017 · Cited by 83
On the Convergence of the Em Algorithm
Hero, A. O. (2005) · IEEE International Symposium on Information Theory (ISIT) · doi:10.1109/isit.1993.748501 · Cited by 83
Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography
Ahn, S., Chaudhari, A. J., Darvas, F., Bouman, C. A., & Leahy, R. M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/14/013 · Cited by 82
Gimelli, A., Bottai, M., Giorgetti, A., Genovesi, D., Kusch, A., Ripoli, A., & Marzullo, P. (2010) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.110.957399 · Cited by 82
Bayesian estimation of ventricular contours in angiographic images
Figueiredo, M. A. T., & Leitaa, J. M. N. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158946 · Cited by 82
Mourik, J. E. M., Lubberink, M., Klumpers, U. M. H., Comans, E. F. I., Lammertsma, A. A., & Boellaard, R. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.022 · Cited by 81
Poisson Image Reconstruction With Hessian Schatten-Norm Regularization
Lefkimmiatis, S., & Unser, M. A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2271852 · Cited by 81
Dual-isotope PET using positron-gamma emitters
Andreyev, A., & Celler, A. M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/020 · Cited by 81
STIR: Software for Tomographic Image Reconstruction Release 2
Thielemans, K., Mustafovic, S., & Tsoumpas, C. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.354345 · Cited by 81
Preserving Poisson characteristics of PET data with weighted OSEM reconstruction
Michel, C. J., Sibomana, M., Boi, A., Bernard, X., Lonneux, M., Defrise, M., Comtat, C., Kinahan, P. E., & Townsend, D. W. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.774398 · Cited by 81
Quantitative comparison of FBP, EM, and bayesian reconstruction algorithms for the indyPET scanner
Frese, T., Rouze, N. C., Bouman, C. A., Sauer, K. D., & Hutchins, G. D. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808353 · Cited by 81
Tanaka, E. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307809 · Cited by 81
Statistic-based MAP image-reconstruction from Poisson data using Gibbs priors
Hebert, T. J., & Leahy, R. M. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.157228 · Cited by 81
Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability
Meikle, S. R., Hutton, B. F., Bailey, D. L., Hooper, P. K., & FULHAM, M. J. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/10/012 · Cited by 81
Recent Progress in Image DeblurringPreprint
Wang, R., & Tao, D. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1409.6838 · Cited by 103
Unsupervised CT Metal Artifact Learning Using Attention-Guided β-CycleGAN
Lee, J., Gu, J., & Ye, J. C. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3101363 · Cited by 84
Li, X., & Ma, L. (2014) · Combustion and Flame · doi:10.1016/j.combustflame.2014.08.020 · Cited by 80
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review