The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 801–900 of 1,000
Maximum-likelihood reconstruction with ordered subsets in bone SPECT.
Blocklet, D., Seret, A., Popa, N., & Schoutens, A. (1999) · PubMed · Cited by 36
A recursive algorithm for computing Cramer-Rao-type bounds on estimator covariance
Hero, A. O., & Fessler, J. A. (1994) · IEEE Transactions on Information Theory · doi:10.1109/18.335955 · Cited by 36
Regularization in tomographic reconstruction using thresholding estimators
Kalifa, J., Laine, A. F., & Esser, P. D. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809691 · Cited by 36
The design and performance of a simultaneous transmission and emission tomography system
Gullberg, G. T., Morgan, H. T., Zeng, G. L., Christian, P. E., Bella, V. R. D., Tung, C., Maniawski, P. J., Hsieh, Y., & Datz, F. L. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.685291 · Cited by 36
Zimny, M., Kaiser, H., Cremerius, U., Reinartz, P., Schreckenberger, M., Sabri, O., & Buell, U. (1999) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050454 · Cited by 36
PARALLELPROJ—an open-source framework for fast calculation of projections in tomography
Schramm, G., & Thielemans, K. (2024) · Frontiers in Nuclear Medicine · doi:10.3389/fnume.2023.1324562 · Cited by 35
Micro-imaging of amyloid in mice.
Wall, J., Paulus, M., Gleason, S., Gregor, J., Solomon, A., & Kennel, S. (2006) · Methods in Enzymology · doi:10.1016/s0076-6879(06)12011-x · Cited by 35
A filtered backprojection algorithm with ray‐by‐ray noise weighting
Zeng, G. L., & Zamyatin, A. A. (2013) · Medical Physics · doi:10.1118/1.4790696 · Cited by 35
Kösters, T., Schäfers, K. P., & Wübbeling, F. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153840 · Cited by 35
A Comparative Study of Popular Interpolation and Integration Methods for Use in Computed Tomography
Xu, F., & Mueller, K. D. (2006) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2006.1625152 · Cited by 36
Joint PET-MRI image reconstruction using a patch-based joint-dictionary prior
Sudarshan, V. P., Egan, G. F., Chen, Z., & Awate, S. P. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101669 · Cited by 35
Temperature-modulated bioluminescence tomography
Wang, G., Shen, H., Cong, W., Zhao, S., & Wei, G. W. (2006) · Optics Express · doi:10.1364/oe.14.007852 · Cited by 35
Sedarat, F., Lin, E. C., Moore, E. D. W., & Tibbits, G. F. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00089.2004 · Cited by 35
Chinn, G., & Huang, S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.552050 · Cited by 35
Estimating Latent Processes on a Network From Indirect Measurements
Airoldi, E. M., & Blocker, A. W. (2012) · Journal of the American Statistical Association · doi:10.1080/01621459.2012.756328 · Cited by 35
Motion Compensated Image Reconstruction of Respiratory Gated PET/CT
Manjeshwar, R. M., Tao, X., Asma, E., & Thielemans, K. (2006) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2006.1625006 · Cited by 35
Influence of PET reconstruction para meters on the TrueX algorithm
Rausch, I., Bergmann, H., Dudczak, R., Hirtl, A., Georg, D., & Knäusl, B. (2013) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0523-12-07 · Cited by 35
Augmented Lagrangian method for total generalized variation based Poissonian image restoration
Liu, X. (2016) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2016.03.005 · Cited by 35
LCD Motion Blur Reduction: A Signal Processing Approach
Har-Noy, S., & Nguyen, T.-T. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.914152 · Cited by 35
A data-parallel algorithm for iterative tomographic image reconstruction
Johnson, C. A., & Sofer, A. (1999) · Symposium on the Frontiers of Massively Parallel Computation (Frontiers) · doi:10.1109/fmpc.1999.750592 · Cited by 35
Fully 3-D List-Mode OSEM Accelerated by Graphics Processing Units
Pratx, G., Chinn, G., Habte, F. G., Olcott, P. D., & Levin, C. S. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.354350 · Cited by 35
Fast iterative image reconstruction of 3D PET data
Kinahan, P. E., Michel, C. J., Defrise, M., Townsend, D. W., Sibomana, M., Lonneux, M., Newport, D. F., & Luketich, J. D. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.588009 · Cited by 35
Yanch, J. C., Dobrzeniecki, A. B., Ramanathan, C., & Behrman, R. H. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/4/003 · Cited by 35
Matrix-Based Image Reconstruction Methods for Tomography
Llacer, J., & Meng, J. D. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336955 · Cited by 35
Cone-beam transmission computed tomography for nonuniform attenuation compensation of SPECT images.
Manglos, S. H., Bassano, D. A., & Thomas, F. D. (1991) · PubMed · Cited by 35
Multiscale Analysis of Photon-Limited Astronomical Images
Willett, R. M. (2007) · ASPC · Cited by 34
Schraml, C., Schmid, M., Gatidis, S., Schmidt, H., la Fougère, C. J., Nikolaou, K., & Schwenzer, N. F. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24865 · Cited by 34
Fully 4D list-mode reconstruction applied to respiratory-gated PET scans
Grotus, N., Reader, A. J., Stute, S., Rosenwald, J., Giraud, P., & Buvat, I. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/020 · Cited by 34
Wolf, P. A., Jørgensen, J. S., Schmidt, T. G., & Sidky, E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5629 · Cited by 31
Ritt, P., Sanders, J. C., & Kuwert, T. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0086-7 · Cited by 34
Theoretical study of penalized-likelihood image reconstruction for region of interest quantification
Qi, J., & Huesman, H. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.873223 · Cited by 34
Efthimiou, N., Emond, E. C., Wadhwa, P., Cawthorne, C., Tsoumpas, C., & Thielemans, K. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aaf9b9 · Cited by 34
REDAEP: Robust and Enhanced Denoising Autoencoding Prior for Sparse-View CT Reconstruction
Zhang, F., Zhang, M., Qin, B., Zhang, Y., Xu, Z., Liang, D., & Liu, Q. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.2989634 · Cited by 35
Imaging the 511 keV Positron Annihilation Sky with COSI
Siegert, T., Boggs, S. E., Tomsick, J. A., Zoglauer, A. C., Kierans, C. A., Sleator, C. C., Beechert, J., Brandt, T. J., Jean, P., Lazar, H., et al. (2020) · The Astrophysical Journal · doi:10.3847/1538-4357/ab9607 · Cited by 34
Ricciato, F., Lanzieri, G., Wirthmann, A., & Seynaeve, G. (2020) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2020.101263 · Cited by 34
Xue, H., Zhang, Q., Zou, S., Zhang, W., Zhou, C., Tie, C., Wan, Q., Teng, Y., Li, Y., Liang, D., et al. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-66 · Cited by 34
Convergence study of an accelerated ML-EM algorithm using bigger step size
Hwang, D.-S., & Zeng, G. L. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/2/004 · Cited by 34
Kim, S. M., Lee, J. S., Lee, M. N., Lee, J. H., Lee, C. S., Kim, C.-H., Lee, D. S., & Lee, S. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.076 · Cited by 34
Byrne, C. L. (2009) · International Transactions in Operational Research · doi:10.1111/j.1475-3995.2008.00683.x · Cited by 34
Gibbs Artifact Reduction by Nonnegativity Constraint
Zeng, G. L. (2011) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.110.086439 · Cited by 34
Stute, S., Carlier, T., Cristina, K., Noblet, C., Martineau, A., Hutton, B. F., Barnden, L. R., & Buvat, I. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/19/017 · Cited by 34
Tomography as a promising diagnostic tool for plasma turbulence
Fujisawa, A., Nagashima, Y., Inagaki, S., Onchi, T., Ohshima, S., & Shimizu, A. (2016) · Plasma Physics and Controlled Fusion · doi:10.1088/0741-3335/58/2/025005 · Cited by 34
A distributed learning framework for heterogeneous data sources
Merugu, S., & Ghosh, J. (2005) · ACM SIGKDD Conference on Knowledge Discovery and Data Mining (KDD) · doi:10.1145/1081870.1081896 · Cited by 34
Two‐dimensional iterative region‐of‐interest (ROI) reconstruction from truncated projection data
Zhang, B., & Zeng, G. L. (2007) · Medical Physics · doi:10.1118/1.2436969 · Cited by 34
Prediction of human observer performance by numerical observers: an experimental study
Narayan, T. K., & Herman, G. T. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.000679 · Cited by 34
Politte, D. G., & Snyder, D. L. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12796 · Cited by 34
Midwave-infrared snapshot imaging spectrometer
Volin, C., Garcia, J. P., Dereniak, E. L., Descour, M. R., Hamilton, T., & McMillan, R. (2001) · Applied Optics · doi:10.1364/ao.40.004501 · Cited by 34
SPMD cluster-based parallel 3D OSEM
Jones, J. P., Jones, W. F., Kehren, F., Newport, D. F., Reed, J. H., Lenox, M., Baker, K., Byars, L. G., Michel, C. J., & Casey, M. E. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817960 · Cited by 34
Improved resolution for PET volume imaging through three-dimensional iterative reconstruction.
Liow, J., Strother, S. C., Rehm, K., & Rottenberg, D. A. (1997) · PubMed · Cited by 34
Artifacts in camera based single photon emission tomography due to time activity variation
Bok, B. D., Bice, A. N., Clausen, M., Wong, D. F., & Wagner, H. N. (1987) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00281856 · Cited by 34
Maximum likelihood reconstruction for cone beam SPECT: development and initial tests
Manglos, S. H., Jaszczak, R. J., & Floyd, C. E. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/12/018 · Cited by 34
Ordered subsets convex algorithm for 3D terahertz transmission tomography
Recur, B., Balacey, H., Sleiman, J. B., Perraud, J.-B., Guillet, J.-P., Kingston, A. M., & Mounaix, P. (2014) · Optics Express · doi:10.1364/oe.22.023299 · Cited by 33
Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix
Cabello, J., & Rafecas, M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/1759 · Cited by 34
Cui, J., Pratx, G., Meng, B., & Levin, C. S. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2252913 · Cited by 33
Kreisch, C. D., O’Sullivan, J. A., Arvidson, R. E., Politte, D. V., He, L., Stein, N., Finkel, J. M., GUINNESS, E. A., Wolff, M. J., & Lapôtre, M. G. A. (2016) · Icarus · doi:10.1016/j.icarus.2016.09.033 · Cited by 33
Multi-pinhole fluorescent x-ray computed tomography for molecular imaging
Sasaya, T., Sunaguchi, N., Hyodo, K., Zeniya, T., & Yuasa, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-05179-2 · Cited by 33
Feasibility of quasi-prompt PET-based range verification in proton therapy
Ozoemelam, I., van der Graaf, E. R., van Goethem, M., Kapusta, M., Zhang, N., Brandenburg, S., & Dendooven, P. G. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba504 · Cited by 33
A rotating modulation imager for locating mid-range point sources
Kowash, B. R., Wehe, D. K., & Fessler, J. A. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.12.233 · Cited by 33
Nomura, K., Kishi, T., Shirai, K., Hirata, Y., & Kotaro, K. (2014) · Welding in the World · doi:10.1007/s40194-014-0211-2 · Cited by 33
Hudson, H. M., & Lee, T. C. M. (1998) · Computational Statistics & Data Analysis · doi:10.1016/s0167-9473(97)00041-8 · Cited by 33
An Overview of Attenuation and Scatter Correction of Planar and SPECT Data for Dosimetry Studies
King, M. A., & Farncombe, T. H. (2003) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/108497803765036346 · Cited by 33
Christiaens, M., Sutter, B. D., Bosschere, K. D., Campenhout, J. V., & Lemahieu, I. A. (1999) · Journal of Systems Architecture · doi:10.1016/s1383-7621(98)00038-1 · Cited by 33
A globally convergent regularized ordered-subset EM algorithm for list-mode reconstruction
Khurd, P., Hsiao, I., Rangarajan, A., & Gindi, G. R. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829780 · Cited by 33
Snyder, D. L., O’Sullivan, J. A., Whiting, B. R., Murphy, R. J., Benac, J., Cataldo, J. A., Politte, D. G., & Williamson, J. F. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959298 · Cited by 33
3D PET List-Mode Iterative Reconstruction Using Time-Of-Flight Information
Groiselle, C. J., & Glick, S. J. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1462792 · Cited by 33
Pan, T.-S., King, M. A., Luo, D.-S., Dahlberg, S. T., & Villegas, B. J. (1997) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(97)90048-9 · Cited by 33
Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery
Pan, T.-S., Luo, D.-S., Kohli, V., & King, M. A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/12/015 · Cited by 33
Scaling techniques for gradient projection-type methods in astronomical image deblurring
Bonettini, S., Landi, G., Piccolomini, E. L., & Zanni, L. (2012) · International Journal of Computer Mathematics · doi:10.1080/00207160.2012.716513 · Cited by 32
Data analysis in emission tomography using emission-count posteriors
Sitek, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/6779 · Cited by 32
Richardson–Lucy deblurring for scenes under a projective motion path
Tai, Y., & Brown, M. S. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107360181.009 · Cited by 32
Zeng, T., Gao, J., Gao, D., Kuang, Z., Sang, Z., Wang, X., Hu, L., Chen, Q., Chu, X., Liang, D., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba6f9 · Cited by 32
Image distortion and correction in single photon emission CT
Ogawa, K. (2004) · Annals of Nuclear Medicine · doi:10.1007/bf02984998 · Cited by 32
nisch, F. P., Enghardt, W., & Lauckner, K. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/312 · Cited by 32
Yan, M., & Vese, L. A. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.878238 · Cited by 32
Iterative Kinetic Parameter Estimation within Fully 4D PET Image Reconstruction
Reader, A. J., Matthews, J. C., Sureau, F. C., Comtat, C., Trébossen, R., & Buvat, I. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.354235 · Cited by 32
Past and future directions in x‐ray computed tomography (CT)
Natterer, F., & Ritman, E. L. (2002) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.10021 · Cited by 32
Sparsity-constrained PET image reconstruction with learned dictionaries
Tang, J., Yang, B., Wang, Y., & Ying, L. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/17/6347 · Cited by 32
Use of a fast EM algorithm for 3D image reconstruction with the YAP–PET tomograph
Motta, A., Damiani, C., Guerra, A. D., Domenico, G. D., & Zavattini, G. (2002) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(02)00034-4 · Cited by 32
O’Sullivan, F., Yudi Pawitan, Y., & Haynor, D. R. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251115 · Cited by 32
A new reconstruction strategy for image improvement in pinhole SPECT
Zeniya, T., Watabe, H., Aoi, T., Kim, K. M., Teramoto, N., Hayashi, T., Sohlberg, A. O., Kudo, H., & Iida, H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1510-4 · Cited by 32
Bruyant, P. P., Gifford, H. C., Gindi, G. R., & King, M. A. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.823050 · Cited by 32
High resolution and better quantification by tube of response modelling in 3D PET reconstruction
Terstegge, A., Weber, S., Herzog, H. R., Müller-Gärtner, H.-W., & Halling, H. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1996.587931 · Cited by 32
T-SPECT: a novel imaging technique for small animal research
Lackas, C., Schramm, N. U., Hoppin, J., Engeland, U., Wirrwar, A., & Halling, H. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.843615 · Cited by 32
Compensation for collimator divergence in SPECT using inverse Monte Carlo reconstruction
Floyd, C. E., Jaszczak, R. J., Manglos, S. H., & Coleman, R. E. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12832 · Cited by 32
Hart, H. E., & Liang, Z. (1987) · Bulletin of Mathematical Biology · doi:10.1007/bf02459960 · Cited by 32
A review of state-of-the-art resolution improvement techniques in SPECT imaging
Cheng, Z., Chen, P., & Yan, J. (2025) · EJNMMI Physics · doi:10.1186/s40658-025-00724-9 · Cited by 31
In vivo Validation of Reconstruction-Based Resolution Recovery for Human Brain Studies
Mourik, J. E. M., Lubberink, M., van Velden, F. H. P., Kloet, R. W., van Berckel, B. N. M., Lammertsma, A. A., & Boellaard, R. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.225 · Cited by 31
Hierarchical regularization for edge-preserving reconstruction of PET images
Bardsley, J. M., Daniela Calvetti, A., & Somersalo, E. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/3/035010 · Cited by 31
Application of the split‐gradient method to 3D image deconvolution in fluorescence microscopy
Vicidomini, G., Boccacci, P., Diaspro, A., & Bertero, M. (2009) · Journal of Microscopy · doi:10.1111/j.1365-2818.2009.03150.x · Cited by 31
Assessing Antibody Pharmacokinetics in Mice with In Vivo Imaging
Hoppin, J., Orcutt, K. D., Hesterman, J. Y., Silva, M. D., Cheng, D., Lackas, C., & Rusckowski, M. (2011) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.110.172916 · Cited by 31
Ortuño, J. E., Kontaxakis, G., Rubio, J. L., Guerra, P., & Santos, A. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/7/004 · Cited by 31
Fast Projection Matching for X-ray Tomography
Wang, C., Chiang, C.-C., Liang, B., Yin, G.-C., Weng, Y.-T., & Wang, L. (2017) · Scientific Reports · doi:10.1038/s41598-017-04020-0 · Cited by 31
Bayesian Inference and Uncertainty Quantification for Medical Image Reconstruction with Poisson Data
Zhou, Q., Yu, T., Zhang, X., & Li, J. (2020) · SIAM Journal on Imaging Sciences · doi:10.1137/19m1248352 · Cited by 31
Gap compensation during PET image reconstruction by constrained, total variation minimization
Ahn, S., Kim, S. M., Son, J., Lee, D. S., & Lee, J. S. (2012) · Medical Physics · doi:10.1118/1.3673775 · Cited by 31
Kim, S. M., Lee, J. S., Lee, C. S., Kim, C. H., Lee, M. C., Lee, D. S., & Lee, S. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/17/009 · Cited by 31
Inversion of velocity map ion images using iterative regularization and cross validation
Renth, F., Riedel, J., & Temps, F. (2006) · Review of Scientific Instruments · doi:10.1063/1.2176056 · Cited by 31
Common Lyapunov Function Based on Kullback–Leibler Divergence for a Switched Nonlinear System
Al-Ola, O. M. A., Fujimoto, K., & Yoshinaga, T. (2011) · Mathematical Problems in Engineering · doi:10.1155/2011/723509 · Cited by 31
On an iterative method for the unfolding of spectra
Mülthei, H. N., & Schorr, B. (1987) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(87)90759-5 · Cited by 31
Moore, S. C., Southekal, S. S., Park, M., McQuaid, S. J., Kijewski, M. F., & Müller, S. P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2169981 · Cited by 31
Anconelli, B., Bertero, M., Boccacci, P., Carbillet, M., & Lantéri, H. (2006) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20053848 · Cited by 31
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review