Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 201–300 of 1,000
FDG PET for detection and therapy control of metastatic germ cell tumor.
Cremerius, U., Effert, P. J., Adam, G., Sabri, O., Zimmy, M., Wagenknecht, G., Jakse, G., & Buell, U. (1998) · PubMed · Cited by 143
Parallel application of block-iterative methods in medical imaging and radiation therapy
Censor, Y. (1988) · Mathematical Programming · doi:10.1007/bf01589408 · Cited by 143
Miller, M. I., & Snyder, D. L. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13825 · Cited by 143
ASNC imaging guidelines for nuclear cardiology procedures
Tilkemeier, P. L., Bourque, J. M., Doukky, R., Sanghani, R. M., & Weinberg, R. L. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-1057-y · Cited by 142
Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction
Wang, G., Vannier, M. W., & Cheng, P. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699000057 · Cited by 140
Ramos, C. D., Erdi, Y. E., Gönen, M., Riedel, E., YEUNG, H. W. D., Macapinlac, H. A., Chisin, R., & Larson, S. M. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000421 · Cited by 139
Unfolding quantum computer readout noise
Nachman, B. P., Urbánek, M., de Jong, W. A., & Bauer, C. (2020) · npj Quantum Information · doi:10.1038/s41534-020-00309-7 · Cited by 138
Snyder, D. L., & Politte, D. G. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4332660 · Cited by 139
Image reconstruction for PET/CT scanners: past achievements and future challenges
Tong, S., Alessio, A. M., & Kinahan, P. E. (2010) · Imaging in Medicine · doi:10.2217/iim.10.49 · Cited by 142
Motion Correction in Dual Gated Cardiac PET Using Mass-Preserving Image Registration
Gigengack, F., Ruthotto, L., Burger, M., Wolters, C. H., Jiang, X., & Schäfers, K. P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175402 · Cited by 138
A statistical multiscale framework for Poisson inverse problems
Nowak, R. D., & Kolaczyk, E. D. (2000) · IEEE Transactions on Information Theory · doi:10.1109/18.857793 · Cited by 137
Sharir, T., Slomka, P. J., Hayes, S. W., DiCarli, M. F., Ziffer, J. A., Martin, W. H., Dickman, D., Ben‐Haim, S., & Berman, D. S. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.028 · Cited by 137
Task-based measures of image quality and their relation to radiation dose and patient risk
Barrett, H. H., Myers, K. J., Hoeschen, C., Kupinski, M. A., & Little, M. P. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/r1 · Cited by 137
Liang, Z., Jaszczak, R. J., & Coleman, R. E. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159772 · Cited by 136
Feasible images and practical stopping rules for iterative algorithms in emission tomography
Llacer, J., & Veklerov, E. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24867 · Cited by 136
Tomographic molecular imaging of x-ray-excitable nanoparticles
Pratx, G., Carpenter, C. M., Sun, C., Rao, R. P., & Xing, L. (2010) · Optics Letters · doi:10.1364/ol.35.003345 · Cited by 135
Kitaura, F.-S., & Enßlin, T. A. (2008) · Monthly Notices of the Royal Astronomical Society · doi:10.1111/j.1365-2966.2008.13341.x · Cited by 134
Light Microscopic Images Reconstructed by Maximum Likelihood Deconvolution
Holmes, T. J., Bhattacharyya, S., Cooper, J. A., Hanzel, D. K., Krishnamurthi, V., Lin, W., Roysam, B., Szarowski, D. H., & Turner, J. N. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_24 · Cited by 133
Scatter Compensation Techniques for SPECT
Jaszczak, R. J., Floyd, C. E., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336941 · Cited by 133
Szanda, I., Mackewn, J. E., Patay, G., Major, P., Sunassee, K., Mullen, G. E. D., Nemeth, G., Hämisch, Y., Blower, P. J., & Marsden, P. K. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.088260 · Cited by 132
An Expanded Theoretical Treatment of Iteration-Dependent Majorize-Minimize Algorithms
Jacobson, M. W., & Fessler, J. A. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.904387 · Cited by 131
Liu, Z., Kastis, G. A., Stevenson, G. D., Barrett, H. H., Furenlid, L. R., Kupinski, M. A., Patton, D. D., & Wilson, D. W. (2002) · PubMed · Cited by 131
Lipinski, B., Herzog, H. R., Kops, E. R., Oberschelp, W., & Müller-Gärtner, H.-W. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563658 · Cited by 131
Accelerated Simulation of Cone Beam X-Ray Scatter Projections
Colijn, A. P., & Beekman, F. J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825600 · Cited by 131
Nonlocal Prior Bayesian Tomographic Reconstruction
Chen, Y., Ma, J., Feng, Q., Luo, L., Shi, P., & Chen, W. (2007) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-007-0042-5 · Cited by 130
Advances in PET Image Reconstruction
Reader, A. J., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.08.001 · Cited by 130
Lantéri, H., Roche, M., & Aime, C. J. (2002) · Inverse Problems · doi:10.1088/0266-5611/18/5/313 · Cited by 130
Maximum-likelihood image restoration adapted for noncoherent optical imaging
Holmes, T. J. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.000666 · Cited by 130
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
Linear and Nonlinear Image Deblurring: A Documented Study
Carasso, A. S. (1999) · SIAM Journal on Numerical Analysis · doi:10.1137/s0036142997320413 · Cited by 129
Iterative reconstruction algorithms in nuclear medicine
Vandenberghe, S., D’Asseler, Y., Rik Van De Walle, B., Kauppinen, T., Koole, M. J. B., Bouwens, L., Laere, K. V., Lemahieu, I. A., & Dierckx, R. A. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00060-4 · Cited by 129
Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer
Knöll, F., Höller, M., Koesters, T., Otazo, R., Bredies, K., & Sodickson, D. K. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2564989 · Cited by 128
Use of a Monte Carlo-based probability matrix for 3-D iterative reconstruction of MADPET-II data
Rafecas, M., Mosler, B., Dietz, M., Pögl, M., Stamatakis, A., McElroy, D. P., & Ziegler, S. I. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.834827 · Cited by 128
Detector response models for statistical iterative image reconstruction in high resolution PET
Selivanov, V. V., Picard, Y., Cadorette, J., Rodrigue, S., & Lecomte, R. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.856565 · Cited by 127
Direct Estimation of Kinetic Parametric Images for Dynamic PET
Wang, G., & Qi, J. (2013) · Theranostics · doi:10.7150/thno.5130 · Cited by 127
Fast iterative algorithm for metal artifact reduction in X-ray CT
Wang, G., Frei, T., & Vannier, M. W. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80576-0 · Cited by 127
A clinical perspective of accelerated statistical reconstruction
Hutton, B. F., Hudson, H. M., & Beekman, F. J. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00879671 · Cited by 126
The modelling of positron emitter production and PET imaging during carbon ion therapy
Pönisch, F., Parodi, K., Hasch, B. G., & Enghardt, W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/002 · Cited by 125
Lehner, C. E., He, Z. J., & Zhang, F. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.832573 · Cited by 125
Zeng, G. L., & Gullberg, G. T. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.173222 · Cited by 125
Design and evaluation of the MAMMI dedicated breast PET
Moliner, L., González, A. J., Soriano, A., Sánchez, F., Correcher, C., Orero, A., Carles, M., Vidal, L., Barberá, J., Caballero, L., et al. (2012) · Medical Physics · doi:10.1118/1.4742850 · Cited by 124
Patient specific quality assurance for the delivery of intensity modulated radiotherapy
Agazaryan, N., Solberg, T. D., & DeMarco, J. J. (2003) · Journal of Applied Clinical Medical Physics · doi:10.1120/1.1525243 · Cited by 124
Noise models for low counting rate coherent diffraction imaging
Godard, P., Allain, M., Chamard, V., & Rodenburg, J. M. (2012) · Optics Express · doi:10.1364/oe.20.025914 · Cited by 122
A prototype coded aperture detector for small animal SPECT
Meikle, S. R., Kench, P. L., Weisenberger, A. G., Wojcik, R. F., Smith, M. F., Majewski, S., Eberl, S., Fulton, R., Rosenfeld, A. B., & FULHAM, M. J. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.803802 · Cited by 122
Hybrid-Domain Neural Network Processing for Sparse-View CT Reconstruction
Hu, D., Liu, J., Lv, T., Zhao, Q., Zhang, Y., Quan, G., Feng, J. J., Chen, Y., & Luo, L. (2020) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2020.3011413 · Cited by 121
Recent technologic advances in nuclear cardiology
Patton, J. A., Slomka, P. J., Germano, G., & Berman, D. S. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2007.06.003 · Cited by 121
de Monvel, J. B., Calvez, S. L., & Ulfendahl, M. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76214-5 · Cited by 120
Primer on molecular imaging technology
Levin, C. S. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1973-y · Cited by 120
Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET
Baete, K., Nuyts, J. L., Laere, K. V., Paesschen, W. V., Ceyssens, S. K., Ceuninck, L. D., Gheysens, O. S., Kelles, A., den Eynden, J. V., Suetens, P., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.041 · Cited by 118
Anatomical-Based FDG-PET Reconstruction for the Detection of Hypo-Metabolic Regions in Epilepsy
Baete, K., Nuyts, J. L., Paesschen, W. V., Suetens, P., & Dupont, P. J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825623 · Cited by 119
Tanaka, E., & Kudo, H. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/312 · Cited by 119
King, M. A., Tsui, B. M. W., Pan, T., Glick, S. J., & Soares, E. J. (1996) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(96)90024-0 · Cited by 119
Investigation on reconstruction methods applied to 3D terahertz computed tomography
Recur, B., Younus, A., Salort, S., Mounaix, P., Chassagne, B., Desbarats, P., Caumes, J.-P., & Abraham, E. (2011) · Optics Express · doi:10.1364/oe.19.005105 · Cited by 118
van den Heuvel, O. A., Veltman, D. J., Groenewegen, H. J., Dolan, R. J., Cath, D. C., Boellaard, R., Mesina, C. T., van Balkom, A. J. L. M., van Oppen, P., Witter, M. P., et al. (2004) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2004.06.007 · Cited by 116
Acker, F. V., Maes, A., Vanquickenborne, B., Stuyck, J., Vleugels, S., Bormans, G. M., Mortelmans, L., Nuyts, J. L., & Bellemans, J. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100603 · Cited by 118
Johnson, V. E., Wong, W. H., Hu, X. P., & Chen, C.-T. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.134041 · Cited by 118
Comparison Between ML-EM And WLS-CG Algorithms For Spect Image Reconstruction
Tsui, B. M. W., Zhao, X., Frey, E. C., & Gullberg, G. T. (1991) · IEEE Transactions on Nuclear Science · doi:10.1109/23.124174 · Cited by 118
Information-theoretic image formation
O’Sullivan, J. A., Blahut, R. E., & Snyder, D. L. (1998) · IEEE Transactions on Information Theory · doi:10.1109/18.720533 · Cited by 118
Incorporation of correlated structural images in PET image reconstruction
Ouyang, X., Wong, W. H., Johnson, V. E., Hu, X. P., & Chen, C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363105 · Cited by 118
Megalin is essential for renal proximal tubule reabsorption of (111)In-DTPA-octreotide.
de Jong, M., Barone, R., Krenning, E. P., Bernard, B. F., Melis, M. L., Visser, T. J., Gekle, M., Willnow, T. E., Walrand, S., Jamar, F., et al. (2005) · PubMed · Cited by 117
SPECT dual-energy-window Compton correction: scatter multiplier required for quantification.
Koral, K. F., Swailem, F. M., Buchbinder, S., Clinthorne, N. H., Rogers, W. L., & Tsui, B. M. W. (1990) · PubMed · Cited by 117
4D image reconstruction for emission tomography
Reader, A. J., & Verhaeghe, J. A. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r371 · Cited by 113
Performance evaluation of the 32-module quadHIDAC small-animal PET scanner.
Schäfers, K. P., Reader, A. J., Kriens, M., Knoess, C., Schober, O., & Schäfers, M. A. (2005) · PubMed · Cited by 116
Ordered subset reconstruction for x-ray CT
Beekman, F. J., & Kamphuis, C. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/307 · Cited by 116
Nuyts, J. L., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816960 · Cited by 116
Hojjatoleslami, S. A., Avanaki, K., & Podoleanu, A. G. (2013) · Applied Optics · doi:10.1364/ao.52.005663 · Cited by 114
Review and Prospect: Artificial Intelligence in Advanced Medical Imaging
Wang, S., Cao, G., Wang, Y., Liao, S., Wang, Q., Shi, J., Li, C., & Shen, D. G. (2021) · Frontiers in Radiology · doi:10.3389/fradi.2021.781868 · Cited by 119
Models, Assumptions and Model Checking in Ecological Regressions
Gelman, A., Park, D. K., Ansolabehere, S. D., Price, P. N., & Minnite, L. C. (2001) · Journal of the Royal Statistical Society Series A (Statistics in Society) · doi:10.1111/1467-985x.00190 · Cited by 111
Pixel-based subsets for rapid multi-pinhole SPECT reconstruction
Branderhorst, W., Vastenhouw, B., & Beekman, F. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/7/015 · Cited by 113
The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study
Duvall, W. L., Wijetunga, M. N., Klein, T. M., Razzouk, L., Godbold, J. H., Croft, L. B., & Henzlova, M. J. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9210-x · Cited by 112
A discrepancy principle for Poisson data
Bertero, M., Boccacci, P., Talenti, G., Zanella, R., & Zanni, L. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/10/105004 · Cited by 112
Management of respiratory motion in PET/computed tomography
Pépin, A., Daouk, J., Bailly, P., Hapdey, S., & Meyer, M.-É. (2013) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000048 · Cited by 112
A single-ring OpenPET enabling PET imaging during radiotherapy
Tashima, H., Yamaya, T., Yoshida, E., Kinouchi, S., Watanabe, M., & Tanaka, E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/14/4705 · Cited by 111
España, S., Marcinkowski, R., Keereman, V., Vandenberghe, S., & Holen, R. V. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/13/3405 · Cited by 110
Magnetic Resonance-Guided Positron Emission Tomography Image Reconstruction
Bai, B., Li, Q., & Leahy, R. M. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2012.08.006 · Cited by 110
Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithms
Matej, S., Herman, G. T., Narayan, T. K., Furuie, S. S., Lewitt, R. M., & Kinahan, P. E. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/004 · Cited by 110
Single‐image Tomography: 3D Volumes from 2D Cranial X‐Rays
Henzler, P., Rasche, V., Ropinski, T., & Ritschel, T. (2018) · Computer Graphics Forum · doi:10.1111/cgf.13369 · Cited by 126
Studies of jet mass in dijet and W/Z + jet events
Chatrchyan, S., Khachatryan, V., Sirunyan, A. M., Tumasyan, A., Adam, W., Aguiló, E., Bergauer, T., Dragicevic, M., Erö, J., Fabjan, C. W., et al. (2013) · Journal of High Energy Physics · doi:10.1007/jhep05(2013)090 · Cited by 108
PET Reconstruction With an Anatomical MRI Prior Using Parallel Level Sets
Ehrhardt, M. J., Markiewicz, P. J., Liljeroth, M., Barnes, A., Kolehmainen, V., Duncan, J. S., Pizarro, L., Atkinson, D., Hutton, B. F., Sebastien Ourselin, A., et al. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2549601 · Cited by 108
Bourassa, A., Degenstein, D. A., Gattinger, R. L., & Llewellyn, E. J. (2007) · Journal of Geophysical Research Atmospheres · doi:10.1029/2006jd008079 · Cited by 108
Lantéri, H., Roche, M., Cuevas, O., & Aime, C. J. (2001) · Signal Processing · doi:10.1016/s0165-1684(00)00275-9 · Cited by 108
On some optimization techniques in image reconstruction from projections
Censor, Y., & Herman, G. T. (1987) · Applied Numerical Mathematics · doi:10.1016/0168-9274(87)90028-6 · Cited by 108
Daube-Witherspoon, M. E., Matej, S., Karp, J. S., & Lewitt, R. M. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.910827 · Cited by 108
Fast, Accurate and Shift-Varying Line Projections for Iterative Reconstruction Using the GPU
Pratx, G., Chinn, G., Olcott, P. D., & Levin, C. S. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2006518 · Cited by 107
Constrained Fourier space method for compensation of missing data in emission computed tomography
Karp, J. S., Muehllehner, G., & Lewitt, R. M. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.3925 · Cited by 107
Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study
Beekman, F. J., Kamphuis, C., & Frey, E. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/8/011 · Cited by 106
Tsoumpas, C., Turkheimer, F., & Thielemans, K. (2008) · Medical Physics · doi:10.1118/1.2885369 · Cited by 106
Karakatsanis, N. A., Casey, M., Lodge, M. A., Rahmim, A., & Zaidi, H. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/15/5456 · Cited by 106
Matthews, J. C., Bailey, D. L., Price, P., & Cunningham, V. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/6/012 · Cited by 105
An inter-comparison of three spectral-deconvolution algorithms for gamma-ray spectroscopy
Meng, L.-J., & Ramsden, D. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.872973 · Cited by 105
Quantitative single-photon emission computed tomography: Basic and clinical considerations
Tsui, B. M. W., Zhao, X., Frey, E. C., & McCartney, W. H. (1994) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(05)80248-x · Cited by 105
Liang, Z., Turkington, T. G., Gilland, D. R., Jaszczak, R. J., & Coleman, R. E. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/3/007 · Cited by 105
Medical Image Noise Reduction Using the Sylvester–Lyapunov Equation
Sanches, J., Nascimento, J. C., & Marques, J. S. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2001398 · Cited by 104
Herman, G. T., & Odhner, D. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97583 · Cited by 104
Accurate EM-TV algorithm in PET with low SNR
Sawatzky, A., Brüne, C., Wübbeling, F., Kösters, T., Schäfers, K. P., & Burger, M. (2008) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2008.4774392 · Cited by 103
Hermansen, F., Rosen, S. D., Fath‐Ordoubadi, F., Kooner, J. S., Clark, J. C., Camici, P. G., & Lammertsma, A. A. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050279 · Cited by 103
Fully 3D list‐mode time‐of‐flight PET image reconstruction on GPUs using CUDA
Cui, J., Pratx, G., Prevrhal, S., & Levin, C. S. (2011) · Medical Physics · doi:10.1118/1.3661998 · Cited by 102
Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM
Reader, A. J., Sureau, F. C., Comtat, C., Trébossen, R., & Buvat, I. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/21/005 · Cited by 102
Byrne, C. L. (2007) · A K Peters/CRC Press eBooks · doi:10.1201/9780429295492 · Cited by 102
Pinhole SPECT of mice using the LumaGEM gamma camera
MacDonald, L. R., Patt, B. E., Iwanczyk, J. S., Tsui, B. M. W., Wang, Y., Frey, E. C., Wessell, D. E., Acton, P. D., & Kung, H. F. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.940171 · Cited by 102
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review