The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Maximum Likelihood Reconstruction for Emission Tomography
Abstract
Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Estimates of I maximizing Eq. 1 can be obtained with an expectation maximization algorithm (6, 33–35), but the outcome is typically unstable (36).”
From Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile (2021) · cites this paper as [33]
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,202
Self-citationVeinott, A. F., & Abadie, J. (1968) · Journal of the American Statistical Association · doi:10.2307/2283909 · Cited by 383
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter‐Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 222
Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon Emitters
Budinger, T. F., Derenzo, S. E., Gullberg, G. T., Greenberg, W. L., & Huesman, R. H. (1977) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197701000-00015 · Cited by 200
Ter‐Pogossian, M. M., Raichle, M. E., & Sobel, B. E. (1980) · Scientific American · doi:10.1038/scientificamerican1080-170 · Cited by 173
Relaxation methods for image reconstruction
Herman, G. T., Lent, A. H., & Lutz, P. H. (1978) · Communications of the ACM · doi:10.1145/359340.359351 · Cited by 137
Cho, Z. H., Chan, J., & Eriksson, L. (1976) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1976.4328315 · Cited by 91
Nonparametric Estimation in Renewal Processes
Vardi, Y. (1982) · The Annals of Statistics · doi:10.1214/aos/1176345870 · Cited by 70
Self-citation
Research works printed but not linked: 1
- lakshminarayanan, 1975, Reconstruction from divergent ray data
Cited by
Sorted by citations
Items 401–500 of 1,000
Three-dimensional terahertz computed tomography of human bones
Bessou, M., Chassagne, B., Caumes, J.-P., Pradère, C., Maire, P., Tondusson, M., & Abraham, E. (2012) · Applied Optics · doi:10.1364/ao.51.006738 · Cited by 80
A unified noise analysis for iterative image estimation
Qi, J. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/21/004 · Cited by 80
Biomedical imaging modalities: a tutorial
Acharya, R. S., Wasserman, R. M., Stevens, J., & Hinojosa, C. (1995) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)00043-3 · Cited by 80
LROC analysis of detector-response compensation in SPECT
Gifford, H. C., King, M. A., Wells, R. G., Hawkins, W. G., Narayanan, M. V., & Pretorius, P. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870256 · Cited by 80
Gamma-ray energy-imaging integrated spectral deconvolution
Xu, D., & He, Z. J. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.01.171 · Cited by 79
Primal and Dual Bregman Methods with Application to Optical Nanoscopy
Brüne, C., Sawatzky, A., & Burger, M. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-010-0339-5 · Cited by 79
Blind deblurring of spiral CT images
Jiang, M. F., Wang, G., Skinner, M. W., Rubinstein, J. T., & Vannier, M. W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815075 · Cited by 79
Optimization-based image reconstruction from sparse-view data in offset-detector CBCT
Bian, J., Wang, J., Han, X., Sidky, E. Y., Shao, L., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/2/205 · Cited by 78
Nuyts, J. L., Baete, K., Beque, D., & Dupont, P. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.846850 · Cited by 78
Kim, H., Chen, J., Wang, A., Chuang, C., Held, M., & Pouliot, J. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6878 · Cited by 77
Hybrid Imaging Technology: From Dreams and Vision to Clinical Devices
Patton, J. A., Townsend, D. W., & Hutton, B. F. (2009) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.03.005 · Cited by 75
Towards real-time image deconvolution: application to confocal and STED microscopy
Zanella, R., Zanghirati, G., Cavicchioli, R., Zanni, L., Boccacci, P., Bertero, M., & Vicidomini, G. (2013) · Scientific Reports · doi:10.1038/srep02523 · Cited by 76
High Temporal-Resolution Dynamic PET Image Reconstruction Using a New Spatiotemporal Kernel Method
Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2869868 · Cited by 76
Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.
Sankaran, S., Frey, E. C., Gilland, K. L., & Tsui, B. M. W. (2002) · PubMed · Cited by 76
Parallelization of the EM algorithm for 3-D PET image reconstruction
Chen, C., Lee, S.-Y., & Cho, Z. H. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108585 · Cited by 76
Wang, G., & Qi, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2212203 · Cited by 75
Photon quantum entanglement in the MeV regime and its application in PET imaging
Watts, D. P., Bordes, J., Brown, J. R., Cherlin, A., Newton, R., Allison, J. E., Bashkanov, M., Efthimiou, N., & Zachariou, N. (2021) · Nature Communications · doi:10.1038/s41467-021-22907-5 · Cited by 77
Deconvolution methods for mitigation of transverse blurring in optical coherence tomography
Ralston, T. S., Marks, D. L., Kamalabadi, F., & Boppart, S. A. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.852469 · Cited by 75
Parameter Estimation for Dynamic Studies in Emission-Tomography Systems Having List-Mode Data
Snyder, D. L. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333400 · Cited by 75
Joshi, S. C., & Miller, M. I. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001078 · Cited by 75
SPRINT II: a second generation single photon ring tomograph
Rogers, W. L., Clinthorne, N. H., Shao, L., Chiao, P.-C., Ding, Y., Stamos, J. A., & Koral, K. F. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.14511 · Cited by 75
Image Reconstruction Algorithms in PET
Defrise, M., Kinahan, P. E., & Michel, C. J. (2005) · Springer eBooks · doi:10.1007/1-84628-007-9_4 · Cited by 74
Propagation beam consideration for 3D THz computed tomography
Recur, B., Guillet, J.-P., Manek-Hönninger, I. B., Delagnes, J.-C., Benharbone, W., Desbarats, P., Domenger, J., Canioni, L., & Mounaix, P. (2012) · Optics Express · doi:10.1364/oe.20.005817 · Cited by 74
Convergent incremental optimization transfer algorithms: application to tomography
Ahn, S., Fessler, J. A., Blatt, D., & Hero, A. O. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862740 · Cited by 74
Simultaneous reconstruction and motion estimation for gated cardiac ECT
Gilland, D. R., Mair, B. A., Bowsher, J. E., & Jaszczak, R. J. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.803820 · Cited by 74
Broers, J. L. V., Bronnenberg, N. M. H. J., Kuijpers, H. J. H., Schütte, B., Hutchison, C. J., & Ramaekers, F. C. S. (2002) · European Journal of Cell Biology · doi:10.1078/0171-9335-00282 · Cited by 74
Prvulovich, E. M., Lonn, A. H. R., Bomanji, J. B., Jarritt, P. H., & Ell, P. J. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf01728762 · Cited by 73
Nuclear imaging of the fuel assembly in ignition experiments
Grim, G. P., Guler, N., Merrill, F. E., Morgan, G. L., Danly, C. R., Volegov, P. L., Wilde, C. H., Wilson, D. C., Clark, D. S., Hinkel, D. E., et al. (2013) · Physics of Plasmas · doi:10.1063/1.4807291 · Cited by 73
Bertero, M., & Boccacci, P. (2005) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20052717 · Cited by 73
Recovering the non-linear density field from the galaxy distribution with a Poisson-lognormal filter
Kitaura, F.-S., Jasche, J., & Metcalf, R. B. (2010) · Monthly Notices of the Royal Astronomical Society · doi:10.1111/j.1365-2966.2009.16163.x · Cited by 73
Xu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
Pretorius, P. H., King, M. A., Pan, T.-S., Vries, D. J. D., Glick, S. J., & Byrne, C. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/2/014 · Cited by 72
Non-blind and Blind Deconvolution Under Poisson Noise Using Fractional-Order Total Variation
Chowdhury, M. R., Qin, J., & Lou, Y. (2020) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-020-00987-0 · Cited by 72
Aslan, B., & Zech, G. (2004) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2004.08.071 · Cited by 72
Iterative algorithms for deblurring and deconvolution with constraints
Byrne, C. L. (1998) · Inverse Problems · doi:10.1088/0266-5611/14/6/006 · Cited by 72
Energy-spectral Compton scatter imaging. I. Theory and mathematics
Arendtsz, N. V., & Hussein, E. M. A. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.489441 · Cited by 72
An experimental survey of metal artefact reduction in computed tomography
Mouton, A., Megherbi, N., Slambrouck, K. V., Nuyts, J. L., & Breckon, T. P. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130372 · Cited by 72
Holmes, T. J., & Liu, Y.-H. (1991) · Journal of the Optical Society of America A · doi:10.1364/josaa.8.000893 · Cited by 72
Weighted least-squares reconstruction methods for positron emission tomography
Anderson, J. M. M., Mair, B. A., Rao, M., & Wu, C.-H. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563661 · Cited by 72
A multigrid expectation maximization reconstruction algorithm for positron emission tomography
Ranganath, M. V., Dhawan, A. P., & Mullani, N. A. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.14509 · Cited by 72
Preconditioned alternating projection algorithms for maximum a posteriori ECT reconstruction
Król, A., Li, S., Shen, L., & Xu, Y. (2012) · Inverse Problems · doi:10.1088/0266-5611/28/11/115005 · Cited by 71
Lefkimmiatis, S., Maragos, P. A., & Papandreou, G. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2022008 · Cited by 71
Statistical analysis of maximum likelihood estimator images of human brain FDG PET studies
Llacer, J., Veklerov, E., Coakley, K. J., Hoffman, E. J., & Núñez, J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232250 · Cited by 71
Benchmark evaluation of inversion algorithms for tomographic absorption spectroscopy
Yu, T., & Cai, W. (2017) · Applied Optics · doi:10.1364/ao.56.002183 · Cited by 71
Data Acquisition and Image Reconstruction for 3D PET
Defrise, M., & Kinahan, P. E. (1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2_2 · Cited by 71
MRI-Guided SPECT Perfusion Measures and Volumetric MRI in Prodromal Alzheimer Disease
Fakhri, G. E., Kijewski, M. F., Johnson, K. A., Syrkin, G., Killiany, R., Becker, J. A., Zimmerman, R. E., & Albert, M. (2003) · Archives of Neurology · doi:10.1001/archneur.60.8.1066 · Cited by 69
Fast MLE for SPECT using an intermediate polar representation and a stopping criterion
Hebert, T. J., Leahy, R. M., & Singh, M. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12798 · Cited by 71
Venkatakrishnan, S. V., Drummy, L. F., Jackson, M., Graef, M. D., Simmons, J. P., & Bouman, C. A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2277784 · Cited by 70
MR-guided dynamic PET reconstruction with the kernel method and spectral temporal basis functions
Novosad, P., & Reader, A. J. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4624 · Cited by 70
Solution of inverse problems in image processing by wavelet expansion
Wang, G., Zhang, J., & Pan, G. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.382493 · Cited by 70
AI for PET image reconstruction
Reader, A. J., & Pan, B. (2023) · British Journal of Radiology · doi:10.1259/bjr.20230292 · Cited by 76
Efficient deconvolution methods for astronomical imaging: algorithms and IDL-GPU codes
Prato, M., Cavicchioli, R., Zanni, L., Boccacci, P., & Bertero, M. (2012) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201118681 · Cited by 69
Li, J., Florian Luisier, A., & Blu, T. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2753404 · Cited by 69
Reconstruction methods and completeness conditions for two Compton data models
Smith, B. D. (2005) · Journal of the Optical Society of America A · doi:10.1364/josaa.22.000445 · Cited by 68
Transaxial system models for jPET-D4 image reconstruction
Yamaya, T., Hagiwara, N., Obi, T., Yamaguchi, M., Ohyama, N., Kitamura, K., Hasegawa, T., Haneishi, H., Yoshida, E., Inadama, N., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/22/009 · Cited by 68
Carson, R. E., Yan, Y., Chodkowski, B., Yap, T. K., & Daube-Witherspoon, M. E. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.310884 · Cited by 68
Hwang, A. B., Franc, B. L., Gullberg, G. T., & Hasegawa, B. H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/002 · Cited by 67
Hutton, B. F., & Lau, Y. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/6/022 · Cited by 67
Collimator-Detector Response Compensation in SPECT
Frey, E. C., & Tsui, B. M. W. (2006) · Springer eBooks · doi:10.1007/0-387-25444-7_5 · Cited by 67
Numerical study of multigrid implementations of some iterative image reconstruction algorithms
Pan, T., & Yagle, A. E. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108592 · Cited by 67
Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile
Mena, G., Martinez, P. P., Mahmud, A. S., Marquet, P. A., Buckee, C. O., & Santillana, M. (2021) · doi:10.1101/2021.01.12.21249682 · Cited by 64
MR-Guided Kernel EM Reconstruction for Reduced Dose PET Imaging
Bland, J., Mehranian, A., Belzunce, M. A., Ellis, S., McGinnity, C. J., Hammers, A., & Reader, A. J. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2771490 · Cited by 66
Study of low-dose PET image recovery using supervised learning with CycleGAN
Zhao, K., Zhou, L., Gao, S., Wang, X., Wang, Y., Zhao, X., Wang, H., Liu, K., Zhu, Y., & Ye, H. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238455 · Cited by 66
Demonstration of a high-speed nonscanning imaging spectrometer
Descour, M. R., Volin, C., Dereniak, E. L., Thome, K. J., Schumacher, A. B., Wilson, D. W., & Maker, P. D. (1997) · Optics Letters · doi:10.1364/ol.22.001271 · Cited by 66
Analysis and comparison of two methods for motion correction in PET imaging
Polycarpou, I., Tsoumpas, C., & Marsden, P. K. (2012) · Medical Physics · doi:10.1118/1.4754586 · Cited by 66
Werling, A., Bublitz, O., Doll, J., Adam, L.-E., & Brix, G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/310 · Cited by 66
Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
Wu, M. C., Gao, D., Sievers, R. E., Lee, R. J., Hasegawa, B. H., & Dae, M. W. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00716-2 · Cited by 66
The design and implementation of COSEN, an iterative algorithm for fully 3-D listmode data
Levkovilz, R., Falikman, D., Zibulevsky, M., Ben‐Tal, A., & Nemirovski, A. S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932747 · Cited by 66
Clinically important characteristics of maximum-likelihood reconstruction.
Miller, T. R., & Wallis, J. W. (1992) · PubMed · Cited by 66
Higher SNR PET image prediction using a deep learning model and MRI image
Liu, C., & Qi, J. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab0dc0 · Cited by 68
X-Ray Luminescence and X-Ray Fluorescence Computed Tomography: New Molecular Imaging Modalities
Ahmad, M. U., Pratx, G., Bazalova‐Carter, M., & Xing, L. (2014) · IEEE Access · doi:10.1109/access.2014.2353041 · Cited by 65
Development of a system for magnetic particle imaging using neodymium magnets and gradiometer
Murase, K., Hiratsuka, S., Song, R., & Takeuchi, Y. (2014) · Japanese Journal of Applied Physics · doi:10.7567/jjap.53.067001 · Cited by 65
Teymurazyan, A., Riauka, T., Jans, H., & Robinson, D. M. (2012) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-012-9511-5 · Cited by 65
Regularization strategies in statistical image reconstruction of low‐dose x‐ray CT : A review
Zhang, H., Wang, J., Zeng, D., Tao, X., & Ma, J. (2018) · Medical Physics · doi:10.1002/mp.13123 · Cited by 65
Deblurring shaken and partially saturated images
Whyte, O., Šivic, J., & Zisserman, A. (2011) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2011.6130327 · Cited by 65
Imaging Brain Function with Positron Emission Tomography
Cherry, S. R., & Phelps, M. E. (2002) · Elsevier eBooks · doi:10.1016/b978-012693019-1/50020-4 · Cited by 65
Reconstruction of SPECT images using generalized matrix inverses
Smith, M. F., Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141640 · Cited by 65
Depth-Aware Motion Deblurring Using Loopy Belief Propagation
Sheng, B., Li, P., Fang, X., Tan, P., & Wu, E. (2019) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2019.2901629 · Cited by 64
Parametric Imaging With PET and SPECT
Gallezot, J., Lu, Y., Naganawa, M., & Carson, R. E. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2019.2908633 · Cited by 64
Total Variation Processing of Images with Poisson Statistics
Sawatzky, A., Brüne, C., Müller, J., & Burger, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-03767-2_65 · Cited by 64
An alternating extragradient method for total variation-based image restoration from Poisson data
Bonettini, S., & Ruggiero, V. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/9/095001 · Cited by 64
Experimental Comparison of Lesion Detectability for Four Fully-3D PET Reconstruction Schemes
Kadrmas, D. J., Casey, M. E., Black, N., Hamill, J. J., Panin, V., & Conti, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2006520 · Cited by 63
Maxim, V., Lojacono, X., Hilaire, E., Krimmer, J., Testa, É., Dauvergne, D., Magnin, I. E., & Prost, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/243 · Cited by 64
Llacer, J., Solberg, T. D., & Promberger, C. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/10/309 · Cited by 64
Kadrmas, D. J., Frey, E. C., & Tsui, B. M. W. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/7/319 · Cited by 64
On the Iterative Image Space Reconstruction Algorthm for ECT
Titterington, D. M. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307797 · Cited by 64
Sastry, S., & Carson, R. E. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650872 · Cited by 64
Yao, R., Seidel, J., Johnson, C. A., Daube-Witherspoon, M. E., Green, M. V., & Carson, R. E. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876305 · Cited by 64
Maximum Likelihood PET with Real Data
Shepp, L. A., Vardi, Y., Ra, J. B., Hilal, S. K., & Cho, Z. H. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333398 · Cited by 64
Self-citationFast methods for including attenuation in the EM algorithm
Hebert, T. J., & Leahy, R. M. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106710 · Cited by 64
Physics and Instrumentation in PET
Bailey, D. L., Karp, J. S., & Surti, S. (2006) · Springer eBooks · doi:10.1007/1-84628-007-9_2 · Cited by 63
Scheins, J. J., Herzog, H. R., & Shah, N. J. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2109732 · Cited by 63
First Human Brain Imaging by the jPET-D4 Prototype With a Pre-Computed System Matrix
Yamaya, T., Yoshida, E., Obi, T., Ito, H., Yoshikawa, K., & Murayama, H. (2008) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.2003252 · Cited by 63
Stroobants, S. G., D'Hoore, I., Dooms, C., Leyn, P. R. D., Dupont, P. J., Wever, W. D., de Groot, T., Verschakelen, J., Mortelmans, L. A., & Vansteenkiste, J. (2003) · Clinical Lung Cancer · doi:10.3816/clc.2003.n.005 · Cited by 63
Collimator scatter and 2D dosimetry in small proton beams
van Luijk, P., Veld, A. A. V. ‘., Zelle, H. D., & Schippers, J. M. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/303 · Cited by 63
Seo, Y., Wong, K. H., Sun, M., Franc, B. L., Hawkins, R. A., & Hasegawa, B. H. (2005) · PubMed · Cited by 63
Brix, G., Doll, J., Bellemann, M. E., Trojan, H., Haberkorn, U., Schmidlin, P., & Ostertag, H. J. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00879667 · Cited by 62
Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/8/006 · Cited by 62
Estimation of images and nonrigid deformations in gated emission CT
Mair, B. A., Gilland, D. R., & Sun, J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879323 · Cited by 62
Yokota, T., Kawai, K., Sakata, M., Kimura, Y., & Hontani, H. (2019) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00322 · Cited by 61
Metadata
- Authors
- Shepp, L. A., & Vardi, Y.
- Affiliations
- AT&T (United States) (US)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1982-10
- Volume
- 1
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2069629287
- Cited by
- 4,429
- References
- 9
- Citations by year
- 2026: 74 · 2025: 101 · 2024: 122 · 2023: 101 · 2022: 117 · 2021: 140 · 2020: 154 · 2019: 153 · 2018: 137 · 2017: 142 · 2016: 152 · 2015: 164 · 2014: 167 · 2013: 182 · 2012: 176
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
- Keywords
- emission tomography, maximum likelihood reconstruction, expectation-maximization algorithm, Poisson likelihood, tomographic reconstruction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review