The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
q-Space Deep Learning: Twelve-Fold Shorter and Model-Free Diffusion MRI Scans
Abstract
Numerous scientific fields rely on elaborate but partly suboptimal data processing pipelines. An example is diffusion magnetic resonance imaging (diffusion MRI), a non-invasive microstructure assessment method with a prominent application in neuroimaging. Advanced diffusion models providing accurate microstructural characterization so far have required long acquisition times and thus have been inapplicable for children and adults who are uncooperative, uncomfortable, or unwell. We show that the long scan time requirements are mainly due to disadvantages of classical data processing. We demonstrate how deep learning, a group of algorithms based on recent advances in the field of artificial neural networks, can be applied to reduce diffusion MRI data processing to a single optimized step. This modification allows obtaining scalar measures from advanced models at twelve-fold reduced scan time and detecting abnormalities without using diffusion models. We set a new state of the art by estimating diffusion kurtosis measures from only 12 data points and neurite orientation dispersion and density measures from only 8 data points. This allows unprecedentedly fast and robust protocols facilitating clinical routine and demonstrates how classical data processing can be streamlined by means of deep learning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
(2010) · International Conference on Machine Learning · Cited by 13,995
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Improving neural networks by preventing co-adaptation of feature detectors
Hinton, G. E., Srivastava, N., Krizhevsky, A., Sutskever, I., & Salakhutdinov, R. R. (2012) · arXiv · doi:10.48550/arxiv.1207.0580 · Cited by 6,382
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
The minimal preprocessing pipelines for the Human Connectome Project
Glasser, M. F., Sotiropoulos, S. N., Wilson, J. A., Coalson, T. S., Fischl, B., Andersson, J. L., Xu, J., Jbabdi, S., Webster, M., Polimeni, J. R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.127 · Cited by 5,253
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
(2010) · Journal of Machine Learning Research · doi:10.5555/1756006.1953039 · Cited by 4,051
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
Practical Recommendations for Gradient-Based Training of Deep Architectures
Bengio, Y. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_26 · Cited by 2,259
What is the best multi-stage architecture for object recognition?
Jarrett, K., Kavukcuoglu, K., Ranzato, M. A., & LeCun, Y. (2009) · 2009 IEEE 12th International Conference on Computer Vision · doi:10.1109/iccv.2009.5459469 · Cited by 2,153
Neural Networks: Tricks of the Trade: Second Edition
(2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8 · Cited by 2,116
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Exact solutions to the nonlinear dynamics of learning in deep linear neural networks
Saxe, A., McClelland, J. L., & Ganguli, S. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1312.6120 · Cited by 931
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891
On the Number of Linear Regions of Deep Neural Networks
Montúfar, G., Pascanu, R., Cho, K., & Bengio, Y. (2014) · arXiv · doi:10.48550/arxiv.1402.1869 · Cited by 840
Deep learning for neuroimaging: a validation study
Plis, S. M., Hjelm, D. R., Salakhutdinov, R., Allen, E. A., Bockholt, H. J., Long, J. D., Johnson, H. J., Paulsen, J. S., Turner, J. A., & Calhoun, V. D. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00229 · Cited by 586
Veraart, J., Sijbers, J., Sunaert, S., Leemans, A., & Jeurissen, B. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.028 · Cited by 504
Automated segmentation of multiple sclerosis lesions by model outlier detection
Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938237 · Cited by 489
Prediction as a candidate for learning deep hierarchical models of data
Palm, R. (2012) · Cited by 444
Lu, H., Jensen, J. H., Ramani, A., & Helpern, J. A. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1020 · Cited by 420
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Exact solutions to the nonlinear dynamics of learning in deep linear neural networks
Saxe, A., McClelland, J. L., & Ganguli, S. (2014) · International Conference on Learning Representations · Cited by 324
Towards better MR characterization of neural tissues using directional diffusion kurtosis analysis
Hui, E. S., Cheung, M. M., Qi, L., & Wu, E. X. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.237 · Cited by 271
Cheung, M. M., Hui, E. S., Chan, K. C., Helpern, J. A., Qi, L., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.018 · Cited by 259
The physical and biological basis of quantitative parameters derived from diffusion MRI.
Winston, G. P. (2012) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2012.12.05 · Cited by 231
Optimal Experimental Design for Diffusion Kurtosis Imaging
Poot, D. H. J., den Dekker, A. J., Achten, E., Verhoye, M., & Sijbers, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2037915 · Cited by 208
D -eigenvalues of diffusion kurtosis tensors
Qi, L., Wang, Y., & Wu, E. X. (2007) · Journal of Computational and Applied Mathematics · doi:10.1016/j.cam.2007.10.012 · Cited by 161
Image Quality Transfer via Random Forest Regression: Applications in Diffusion MRI
Alexander, D. C., Zikic, D., Zhang, J., Zhang, H. G., & Criminisi, A. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10443-0_29 · Cited by 134
Experimentally and computationally fast method for estimation of a mean kurtosis
Hansen, B., Lund, T. E., Sangill, R., & Jespersen, S. N. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24743 · Cited by 132
Accelerated diffusion spectrum imaging in the human brain using compressed sensing
Menzel, M. I., Tan, E. T., Khare, K., Sperl, J. I., King, K. F., Tao, X., Hardy, C. J., & Marinelli, L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23064 · Cited by 131
Self-citationHori, M., Fukunaga, I., Masutani, Y., Taoka, T., Kamagata, K., Suzuki, Y., & Aoki, S. (2012) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.11.221 · Cited by 126
Machine learning based compartment models with permeability for white matter microstructure imaging
Nedjati-Gilani, G. L., Schneider, T., Hall, M. G., Cawley, N., Hill, I., Ciccarelli, O., Drobnjak, I., Wheeler‐Kingshott, C. A. M. G., & Alexander, D. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.013 · Cited by 124
Veraart, J., Hecke, W. V., & Sijbers, J. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22835 · Cited by 104
Accelerated diffusion spectrum imaging with compressed sensing using adaptive dictionaries
Bilgiç, B., Setsompop, K., Cohen‐Adad, J., Yendiki, A., Wald, L. L., & Elfar Adalsteinsson, A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24505 · Cited by 77
Nilsson, M., Alerstam, E., Wirestam, R., ̊hlberg, F. S., Brockstedt, S., & Lätt, J. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.06.002 · Cited by 73
Xu, J., Li, K., Smith, R. A., Waterton, J. C., Zhao, P., Chen, H., Does, M. D., Manning, H. C., & Gore, J. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0041714 · Cited by 66
White matter compartment models for in vivo diffusion MRI at 300 mT/m
Ferizi, U., Schneider, T., Witzel, T., Wald, L. L., Zhang, H. G., Wheeler‐Kingshott, C. A. M. G., & Alexander, D. C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.027 · Cited by 60
Bagher‐Ebadian, H., Jafari‐Khouzani, K., Mitsias, P. D., Lü, M., Hamid Soltanian-zadeh, A., Chopp, M., & Ewing, J. R. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022626 · Cited by 56
Paquette, M., Merlet, S., Gilbert, G., Rachid Deriche, B., & Descoteaux, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25093 · Cited by 50
A Machine Learning Based Approach to Fiber Tractography Using Classifier Voting
Neher, P. F., Götz, M., Norajitra, T., Weber, C., & Maier-Hein, K. H. (2015) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-24553-9_6 · Cited by 47
q-Space Deep Learning for Twelve-Fold Shorter and Model-Free Diffusion MRI Scans
Golkov, V., Dosovitskiy, A., Sämann, P. G., Sperl, J. I., Sprenger, T., Czisch, M., Menzel, M. I., Gómez, P. A., Haase, A., Brox, T., et al. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24553-9_5 · Cited by 42
Self-citationLearning a Reliable Estimate of the Number of Fiber Directions in Diffusion MRI
Schultz, T. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_61 · Cited by 38
Machine Learning Based Compartment Models with Permeability for White Matter Microstructure Imaging
Nedjati-Gilani, G. L., Schneider, T., Hall, M. G., Wheeler‐Kingshott, C. A. M. G., & Alexander, D. C. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10443-0_33 · Cited by 23
Model-free novelty-based diffusion MRI
Golkov, V., Sprenger, T., Sperl, J. I., Menzel, M. I., Czisch, M., Sämann, P. G., & Cremers, D. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493489 · Cited by 11
Self-citation
Cited by
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Greenspan, H., van Ginneken, B., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553401 · Cited by 1,700
Metadata
- Authors
- Golkov, V., Dosovitskiy, A., Sperl, J. I., Menzel, M. I., Czisch, M., Samann, P., Brox, T., & Cremers, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-05
- Volume
- 35
- Issue
- 5
- Pages
- 1344-1351
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2328247767
- Cited by
- 310
- References
- 53
- FWCI
- 21.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.