Abstract
This study investigated the use of planar, silicon-substrate microelectrodes for chronic unit recording in the cerebral cortex. The 16-channel microelectrodes consisted of four penetrating shanks with four recording sites on each shank. The chronic electrode assembly included an integrated silicon ribbon cable and percutaneous connector. In a consecutive series of six rats, 5/6 (83%) of the implanted microelectrodes recorded neuronal spike activity for more than six weeks, with four of the implants (66%) remaining functional for more than 28 weeks. In each animal, more than 80% of the electrode sites recorded spike activity over sequential recording sessions during the postoperative time period. These results provide a performance baseline to support further electrode system development for intracortical neural implant systems for medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“encompass microelectrode technologies ranging from microwires [9], [10] to various types of silicon micromachining [11], [12], to polymers”
BackgroundConnecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · cited 1×
“These approaches encompass microelectrode technologies ranging from microwires [9], [10] to various types of silicon micromachining [11], [12], to polymers [13].”
BackgroundSelf-citationRestoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Self-citationReconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 375
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Neuronal Interactions Improve Cortical Population Coding of Movement Direction
Maynard, E. M., Hatsopoulos, N. G., Ojakangas, C. L., Acuna, B. D., Sanes, J. N., Normann, R. A., & Donoghue, J. P. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-18-08083.1999 · Cited by 281
A multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 280
Self-citationLiu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245 · cited 2×
“D) arrays [17].”
MethodA direct brain interface based on event-related potentials
Levine, S. P., Huggins, J. E., BeMent, S. L., Kushwaha, R. K., Schuh, L. A., Rohde, M. M., Passaro, E. A., Ross, D. A., Elisevich, K. V., & Smith, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847809 · Cited by 197
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationTechniques for Chronic, Multisite Neuronal Ensemble Recordings in Behaving Animals
Kralik, J. D., Dimitrov, D. F., Krupa, D. J., Katz, D. B., Cohen, D., & Nicolelis, M. A. L. (2001) · Methods · doi:10.1006/meth.2001.1231 · Cited by 162
High density interconnects and flexible hybrid assemblies for active biomedical implants
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.938305 · Cited by 145
Robustness of neuroprosthetic decoding algorithms
Serruya, M. D., Fellows, M. R., Paninski, L., Donoghue, J. P., & Hatsopoulos, N. G. (2003) · Biological Cybernetics · doi:10.1007/s00422-002-0374-6 · Cited by 125
A fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H. I. I. I., Gulari, A. N., & Wise, K. D. (2003) · First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings. · doi:10.1109/cne.2003.1196783 · Cited by 55
Silicon neural recording arrays with on-chip electronics for in-vivo data acquisition
Olsson, R. H., Gulari, M. N., & Wise, K. D. (2003) · 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578) · doi:10.1109/mmb.2002.1002321 · Cited by 55
Characterization of Implantable Microfabricated Fluid Delivery Devices
Rathnasingham, R., Kipke, D. R., Bledsoe, S. C., & McLaren, J. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820311 · Cited by 47
Self-citation3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording
Hetke, J. F., Williams, J. C., Pellinen, D. S., Vetter, R. J., & Kipke, D. R. (2003) · First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings. · doi:10.1109/cne.2003.1196787 · Cited by 39
Self-citationSilicon microelectrodes for extracellular recording
Hetke, J. F., & Anderson, D. (2002) · Biomedical engineering series · doi:10.1201/9781420040876.ch7 · Cited by 32
Self-citationThe use of ALGEL/spl reg/ as an artificial dura for chronic cortical implant neuroprosthetics
Vetter, R. J., Becker, T. A., Williams, J. C., & Kipke, D. R. (2004) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196908 · Cited by 12
Self-citationSilicon microelectrodes for extracellular recording
Finn, W. E., & LoPresti, P. G. (2002) · CRC Press eBooks · doi:10.1201/9781420040876-12 · Cited by 8
CNS RECORDING ELECTRODES AND TECHNIQUES
Kipke, D. R., Pellinen, D. S., & Rousche, P. J. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0023 · Cited by 7
Self-citation
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“…normal silicon nitride or silicon dioxide insulation deposited during the fabrication of micromachined silicon electrodes (Campbell et al., 1991; Kipke et al., 2003), polyesterimide, or more commonly, polyimide is often used to coat silicon-based implants (Campbell et al., 1991; Yuen and Agnew,…”
BackgroundMethodResultInfluentialBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
“…emergence of silicon microfabrication has yielded increasingly smaller and higher electrode count devices that are capable of recording from greater volumes of neural tissue with improved spatial discrimination (Branner et al., 2001; Csicsvari et al., 2003; Drake et al., 1988; Kipke et al., 2003).”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“…(Wise et al., 1970; Najafi and Wise, 1986; Jones et al., 1992; O’Keefe and Recce, 1993; Gray et al., 1995; Bai and Wise, 2001; Csicsvari et al., 2003; Kipke et al., 2003; Blanche et al., 2005; Olsson and Wise, 2005; Fujisawa et al., 2008; Montgomery et al., 2008; Herwik et al., 2009; Du et al.,…”
Metadata
- Authors
- Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 151-155
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2144030012
- Cited by
- 367
- References
- 27
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.