Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This study investigated the use of planar, silicon-substrate microelectrodes for chronic unit recording in the cerebral cortex. The 16-channel microelectrodes consisted of four penetrating shanks with four recording sites on each shank. The chronic electrode assembly included an integrated silicon ribbon cable and percutaneous connector. In a consecutive series of six rats, 5/6 (83%) of the implanted microelectrodes recorded neuronal spike activity for more than six weeks, with four of the implants (66%) remaining functional for more than 28 weeks. In each animal, more than 80% of the electrode sites recorded spike activity over sequential recording sessions during the postoperative time period. These results provide a performance baseline to support further electrode system development for intracortical neural implant systems for medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“encompass microelectrode technologies ranging from microwires [9], [10] to various types of silicon micromachining [11], [12], to polymers”
BackgroundConnecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644 · cited 1×
“These approaches encompass microelectrode technologies ranging from microwires [9], [10] to various types of silicon micromachining [11], [12], to polymers [13].”
BackgroundSelf-citationRestoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Self-citationReconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 375
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 362
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“…normal silicon nitride or silicon dioxide insulation deposited during the fabrication of micromachined silicon electrodes (Campbell et al., 1991; Kipke et al., 2003), polyesterimide, or more commonly, polyimide is often used to coat silicon-based implants (Campbell et al., 1991; Yuen and Agnew,…”
BackgroundMethodResultInfluentialBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
“…emergence of silicon microfabrication has yielded increasingly smaller and higher electrode count devices that are capable of recording from greater volumes of neural tissue with improved spatial discrimination (Branner et al., 2001; Csicsvari et al., 2003; Drake et al., 1988; Kipke et al., 2003).”
BackgroundConducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“…(Wise et al., 1970; Najafi and Wise, 1986; Jones et al., 1992; O’Keefe and Recce, 1993; Gray et al., 1995; Bai and Wise, 2001; Csicsvari et al., 2003; Kipke et al., 2003; Blanche et al., 2005; Olsson and Wise, 2005; Fujisawa et al., 2008; Montgomery et al., 2008; Herwik et al., 2009; Du et al.,…”
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
“potentials (unit spike recording) in the rat cerebral cortex for periods of more than one year [ 101 ].”
BackgroundSelf-citationGlial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Self-citationMultifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Self-citationThree-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“The high flexibility of our macroporous probes precludes direct insertion 14, 20 into neural tissue, and invasive surgery, which could allow for placement of macroporous probes in specific brain regions, would largely eliminate many potential advantages of our design.”
BackgroundProgress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“We specifically focused on the microenvironment immediately adjacent to a microelectrode inserted in the cerebral cortex within the context of performance analysis of implantable microelectrode arrays used in research animals [4, 5, 13, 14, 26].”
BackgroundMethodSelf-citationGuest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Self-citationBjornsson, C. S., Oh, S. J., Al-Kofahi, Y. A., Lim, Y. J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Self-citationBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
Abidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255
Self-citationElectrochemical Biosensing of Dopamine Neurotransmitter: A Review
Lakard, S., Pavel, I.-A., & Lakard, B. (2021) · Biosensors · doi:10.3390/bios11060179 · Cited by 243
“A wide variety of materials have been used for the manufacture of microelectrodes, but the most used electrode materials are noble metals usually, platinum [32,33] or gold [34–39], and carbon materials [40–48], even some metal oxides [49,50] or semiconductors [51,52] can also be used.”
BackgroundEnabling individualized therapy through nanotechnology
Sakamoto, J. H., van de Ven, A. L., Godin, B., Blanco, E., Serda, R. E., Grattoni, A., Ziemys, A., Bouamrani, A., Hu, T., Ranganathan, S. I., et al. (2010) · Pharmacological Research · doi:10.1016/j.phrs.2009.12.011 · Cited by 229
Biomaterials for the central nervous system
Zhong, Y., & Bellamkonda, R. V. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0071 · Cited by 221
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
NeuroMEMS: Neural Probe Microtechnologies
HajjHassan, M., Chodavarapu, V., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 190
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
“…floating microwire arrays (Drake et al., 1988; Rousche and Normann, 1998; Williams et al., 1999a,b; Rousche et al., 2001; Csicsvari et al., 2003; Kipke et al., 2003; Nicolelis et al., 2003; Vetter et al., 2004; Patrick et al., 2006; Jackson and Fetz, 2007; Musallam et al., 2007; Kozai et al.,…”
BackgroundHe, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Recent development in hybrid conducting polymers: Synthesis, applications and future prospects
Iqbal, S., & Ahmad, S. (2018) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2017.09.038 · Cited by 159
Detecting Neural-State Transitions Using Hidden Markov Models for Motor Cortical Prostheses
Kemere, C., Santhanam, G., Yu, B. M., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00924.2007 · Cited by 157
Nanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
“The Si/SiO2 surface is representative of many Si multi-electrode array systems including the Michigan microelectrode system,which is used for chronic unit recording in the cerebral cortex [ 5 ].”
MethodLuan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Based on Si-substrate shanks, the Michigan array can run multiple connective lines down to pads of Ir along a shank to achieve multidepth electrodes (38).”
The Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Scalable batch fabrication of ultrathin flexible neural probes using a bioresorbable silk layer
Cointe, C., Laborde, A., Nowak, L. G., Arvanitis, D. N., Bourrier, D., Bergaud, C., & Maziz, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00353-7 · Cited by 78
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Sharma, G., Annetta, N., Friedenberg, D., Blanco, T., Vasconcelos, D., Shaikhouni, A., Rezai, A. R., & Bouton, C. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00010 · Cited by 41
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Lin, Z.-K., Lin, J.-S., Chen, Z.-H., Cheng, H.-W., Huang, W.-C., & Chen, S.-Y. (2024) · Journal of Materials Chemistry B · doi:10.1039/d3tb02715e · Cited by 7
Metadata
- Authors
- Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 151-155
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2144030012
- Cited by
- 367
- References
- 27
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.