A Computational Model for the Stimulation of Rat Sciatic Nerve Using a Transverse Intrafascicular Multichannel Electrode
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Neuroprostheses based on electrical stimulation could potentially help disabled persons. They are based on neural interface that aim at creating an intimate contact with neural cells. The efficacy of neuroprostheses can be improved by increasing the selectivity of the neural interfaces used to stimulate specific subsets of cells. Selectivity is strongly influenced by interface design. Computer models can be useful for exploring the high dimensional space of design parameters with the aim to provide guidelines for the development of more efficient electrodes, with minimal animal use and optimization of manufacturing processes. The purpose of this study was to implement a realistic model of the performance of a transverse intrafascicular multichannel electrode (TIME) implanted into the rat sciatic nerve. A realistic finite element method (FEM) model was developed taking into account the anatomical and physiological features of the rat sciatic nerve. Electric potentials were calculated and interpolated voltages were applied to the model of a rat sciatic nerve axon, based on experimental biophysical data. Results indicate that high intra-fascicular and inter-fascicular selectivity values with low current levels can be achieved with TIMEs. The selectivity of TIMEs was also compared to an extraneural electrode, showing that higher selectivity with less current can be obtained. Using this model, the robustness of electrode performances for translational and rotational displacements were evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“They range from cuff electrodes, having low invasiveness and low selectivity, to sieve electrodes, having higher selectivity but, unfortunately, also higher invasiveness [ 9 ].”
BackgroundSelf-citationAnalysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 2×
“Fig. 2. Stylized design of the TIME electrode with one side of the modeled part highlighted. Taken, with permission, from [ 21 ].”
BackgroundMethodLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 1×
“They are nowadays based on polyimide, and allow the development of flexible (in order to increase compliancy within the nerve), yet robust (enabling stable stimulation) electrodes with excellent biocompatibilty [ 11 ].”
BackgroundEnergy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm
Wongsarnpigoon, A., & Grill, W. M. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046009 · Cited by 166 · cited 1×
“Since the computational optimization of this kind of model represents a key feature for the future development of heuristicalgorithms [ 28 ], animportant result that had to be reached was the minimal sufficient boundary and meshing conditions giving an electromagnetically correct solution.”
MethodSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · cited 4×
“The robustness analysiswascarriedout toafurtherextentcomparedtoprevious works [ 20 ], introducing indexes which we believe are congenial for the research of minimal correct boundary conditions, and mesh quality, which are essential parameters when trying to optimize the computational load and to measure the accuracy o…”
BackgroundMethodInfluentialFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1×
“The perineurium was also modeled as an isotropic conductor according to [ 25 ] with a value of 0.0021 S/m.”
MethodInfluentialPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Topographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98 · cited 5×
“Three different axonal populations innervating different muscles [gastrocnemius medialis (GM), tibialis anterioris (TA), and plantaris muscles (PL)] were considered [ 24 ] [see Fig. 4(b)].”
BackgroundMethodInfluentialMuscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Fisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · cited 1×
“is defined as the current at which 10% of the total number of fibers innervating the specific muscle are recruited (e.g., an action potential is generated within the axons) [ 37 ].”
Background
Cited by
A Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435
“We previously exploited this reductionism to validate a hybrid computational model of sciatic nerve stimulation (Raspopovic et al., 2012).”
MethodSelf-citationOddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Self-citationGreiner, N., Barra, B., Schiavone, G., Lorach, H., James, N., Conti, S., Kaeser, M., Fallegger, F., Borgognon, S., Lacour, S., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20703-1 · Cited by 199
Self-citationKundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2267936 · Cited by 83
A three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82
“The presence of lateral wings has a dual task: it provides an anchorage system that increases the mechanical stability of the electrode and it may allow the access to further fascicles that may not be interfaced with common planar electrodes (e.g., TIME, tf-LIFE) (Raspopovic et al 2011 and 2012).”
BackgroundSelf-citation
Metadata
- Authors
- Raspopovic, S., Capogrosso, M., & Micera, S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-08
- Volume
- 19
- Issue
- 4
- Pages
- 333-344
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2148432454
- Cited by
- 115
- References
- 14
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.