The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
Abstract
This paper investigates the experimental implementation and detection of rotor faults in permanent magnet synchronous machines. Methods are shown how to experimentally introduce static and dynamic eccentricities and broken magnet cases. A new magnet flux estimation that does not require the measurement of the rotor position or speed is developed. The detection of these and other rotor faults by measuring only the stator currents and voltages are shown experimentally. The paper concludes by contributing a description of a condition-monitoring scheme for detection rotor faults
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489
Operation of fault tolerant machines with winding failures
Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.815095 · Cited by 148
Monitoring the thermal condition of permanent-magnet synchronous motors
Milanfar, P., & Lang, J. H. (1996) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/7.543863 · Cited by 104
le Roux, W., Harley, R. G., & Habetler, T. G. (2005) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2003.1257736 · Cited by 6
Self-citation
Research works printed but not linked: 9
- le roux, 2002, rotor fault analysis of a permanent magnet synchronous machine, Proc 15th Int Conf Elect Mach (ICEM'02)
- 10.1109/APEC.2001.912469 · doi:10.1109/apec.2001.912469
- 10.1109/7.543863 · DOI
- 10.1109/IAS.2000.881138 · doi:10.1109/ias.2000.881138
- 10.1109/APEC.2001.911681 · doi:10.1109/apec.2001.911681
- bianchi, 1997, influence of the current control strategy on the pmsm drive performance during failures, Proc 7th Eur Conf Power Electron Appl (EPE), 1.330
- pal, 1991, design criteria for brushless dc motors with hollow rotor of samarium cobalt for applications above 25000 rpm in vacuum, Electrical Machines and Drives 1991 Fifth International Conference on, 115
- pal, 1991, direct drive high energy permanent magnet brush and brushless dc motors for robotic applications, Robot Actuators IEE Colloquium on, 12/1
- fisher, 1991, design and cost considerations for permanent magnet dc motor applications, Power Conv Intell Motion, 17, 18
Cited by
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“However, the visibility of this symptom is strongly dependent on the configuration of the winding, and sometimes even in the case of demagnetization there are no harmonics or subharmonics other than those that occur in a healthy motor due to the natural existing asymmetries of the machine [19], [29], [84], [85].”
BackgroundDa, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Ebrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Soualhi, A., Clerc, G., & Razik, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230598 · Cited by 264
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
“It is worth noticing that in the second part of (6), the harmonic frequencies owing to the demagnetization fault are the same than in (1), which agrees with the technical literature [3], [13]–[15].”
BackgroundResultHaddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158
A Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
“other mechanical asymmetries produce sidebands components identical to fecc , and there is no practical means of separating them [3], [4].”
BackgroundMethodInfluentialDa, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48
“The measurability of these components for this type of experimental machine has been established in [6], [7], and [12].”
BackgroundSelf-citationKarami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/132647 · Cited by 31
Quality Assurance Testing for Magnetization Quality Assessment of BLDC Motors Used in Compressors
Lee, K.-W., Hong, J., Lee, S. B., & Lee, S. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2075732 · Cited by 27
Detection of magnet demagnetization in five-phase surface-mounted permanent magnet generators
Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., & Zarri, L. (2012) · 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254099 · Cited by 22
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“[24] and [25] proposed an indicator of magnetic defect using the average estimation of magnetic flux and torque constant, and CSA is used for diagnosing of EF, yet the temperature might affect such estimation.”
Metadata
- Authors
- le Roux, W., Harley, R. G., & Habetler, T. G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2007-01
- Volume
- 22
- Issue
- 1
- Pages
- 322-328
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2157677302
- Cited by
- 274
- References
- 4
- FWCI
- 20.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.