The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A Human--Exoskeleton Interface Utilizing Electromyography
Abstract
This paper presents a human--machine interface to control exoskeletons that utilizes electrical signals from the muscles of the operator as the main means of information transportation. These signals are recorded with electrodes attached to the skin on top of selected muscles and reflect the activation of the observed muscle. They are evaluated by a sophisticated but simplified biomechanical model of the human body to derive the desired action of the operator. A support action is computed in accordance to the desired action and is executed by the exoskeleton. The biomechanical model fuses results from different biomechanical and biomedical research groups and performs a sensible simplification considering the intended application. Some of the model parameters reflect properties of the individual human operator and his or her current body state. A calibration algorithm for these parameters is presented that relies exclusively on sensors mounted on the exoskeleton. An exoskeleton for knee joint support was designed and constructed to verify the model and to investigate the interaction between operator and machine in experiments with force support during everyday movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,021
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Electromechanical delay in human skeletal muscle under concentric and eccentric contractions
Cavanagh, P. R., & Komi, P. V. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00431022 · Cited by 802
European recommendations for surface electromyography results of the SENIAM project
Hermens, H. J. (1999) · Cited by 581
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Additional considerations are the performance limitations and saturation effects of the actuator and power source [14,60,170].”
InfluentialProgress and prospects of the human–robot collaboration
Ajoudani, A., Zanchettin, A. M., Ivaldi, S., Albu-Schäffer, A., Kosuge, K., & Khatib, O. (2018) · Autonomous Robots · doi:10.1007/s10514-017-9677-2 · Cited by 832
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
Sartori, M., Reggiani, M., Farina, D., & Lloyd, D. G. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052618 · Cited by 330
Adaptive Impedance Control for an Upper Limb Robotic Exoskeleton Using Biological Signals
Li, Z., Huang, Z., He, W., & Su, C.-Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2538741 · Cited by 323
Dynamic movement primitives in robotics: A tutorial survey
Saveriano, M., Abu-Dakka, F. J., Kramberger, A., & Peternel, L. (2023) · The International Journal of Robotics Research · doi:10.1177/02783649231201196 · Cited by 267
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Sartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
Pang, M., Guo, S., Huang, Q., Ishihara, H., & Hirata, H. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0033-8 · Cited by 53
Metadata
- Authors
- Fleischer, C., & Hommel, G.
- Venue
- IEEE Transactions on Robotics
- Published
- 2008-08
- Volume
- 24
- Issue
- 4
- Pages
- 872-882
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2162438232
- Cited by
- 412
- References
- 33
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.