CoChat

Is it possible to constantly and accurately monitor blood sugar levels, in people with Type 1 diabetes, with a discrete device (non‐invasive or invasive)?

Avari, P., Reddy, M., Oliver, N. · 2020 · Diabetic Medicine
Cited by 44

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Real‐time continuous glucose monitors using subcutaneous needle‐type sensors continue to develop. The limitations of currently available systems, however, include time lag behind changes in blood glucose, the invasive nature of such systems, and in some cases, their accuracy. Non‐invasive techniques have been developed, but, to date, no commercial device has been successful. A key research priority for people with Type 1 diabetes identified by the James Lind Alliance was to identify ways of monitoring blood glucose constantly and accurately using a discrete device, invasive or non‐invasive. Integration of such a sensor is important in the development of a closed‐loop system and the technology must be rapid, selective and acceptable for continuous use by individuals. The present review provides an update on existing continuous glucose‐sensing technologies, and an overview of emergent techniques, including their accuracy and limitations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dme.13942

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 44

Metadata

Authors
Avari, P., Reddy, M., & Oliver, N.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2019-03-13
Volume
37
Issue
4
Pages
532-544
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2916863388
Cited by
44
References
13
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.