Trace determination of lead in lipsticks and hair dyes using microwave‐assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Synopsis: Objective: A novel microwave‐assisted dispersive liquid–liquid microextraction (MADLLME) technique according to the solidification of a floating organic droplet (SFO) and graphite furnace atomic absorption spectrometry (GFAAS) used for the extraction and determination of lead ions in lipsticks and hair dyes made in different countries. Lipstick and hair dye samples of different brands and colours were collected from local market in Kermanshah, Iran. Methods: After sample treatment with microwave‐assisted acid digestion, an appropriate mixture of acetone, 1‐undecanol and diethyl dithiophosphoric acid was injected rapidly into the aqueous sample containing lead ions, and as a result, cloudy mixture was formed. After centrifugation, the test tube was cooled for few minutes. The solidified 1‐undecanol on top of the solution was transferred into a suitable vial and injected into the analytical instrument. Results: Under the optimum experimental conditions (extraction solvent: 30 μL of 1‐undecanol; disperser solvent: 500 μL of acetone; ligand concentration: 0.15% (v/v); pH: ~1.5 and without salt added), the enhancement factor of 96 was obtained. The calibration graphs were linear in the range of 0.3–50 μg kg−1 with a correlation coefficient (r2) more than 0.995. The detection limit was 0.1 μg kg−1. Consequently, the developed method was successfully applied to extract and determine lead ions in the lipsticks and hair dyes, and favourable results were obtained. The proposed method which applied in cosmetics showed excellent relative recoveries (90–109.7%) with relative standard deviations <8.3% (n = 3) for all samples. Conclusion: The study revealed that the concentration of lead found in lipsticks and hair dyes on the Kermanshah market is far below the recommended limits as applied in Germany (20 mg kg−1) and Canada (10 mg kg−1) and confirmed that very low levels of lead are technically available in the final cosmetic products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Leong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413 · cited 1×
“Recently, DLLME based on solidification of floating organic droplet (DLLME–SFO) is developed as a novel sample preparation technique, which follows the same principle as the DLLME technique [21].”
MethodFattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Self-citationZhou, Q., Zhao, N., & Xie, G. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.01.123 · Cited by 138
Górecki, T., & Pawliszyn, J. (1996) · Analytical Chemistry · doi:10.1021/ac9601270 · Cited by 101
Research works printed but not linked: 22
- 10.1016/j.talanta.2012.09.021 · DOI
- 10.1016/j.microc.2011.10.008 · DOI · Paper page
- 10.1016/j.jhazmat.2009.11.045 · DOI
- 10.1289/ehp.6941 · DOI · Paper page
- 10.1016/j.chroma.2008.10.041 · DOI
- 10.1016/j.yrtph.2009.02.005 · DOI · Paper page
- Hepp N.M., 2009, Determination of total lead in lipstick: development and validation of a microwave‐assisted digestion, inductively coupled plasma–mass spectrometric method, J. Cosmet. Sci., 60, 405
- Besecker K.D., 1998, A simple closed‐vessel nitric acid digestion method for cosmetic samples, Atom. Spectros., 19, 48
- 10.1016/j.jhazmat.2009.10.069 · DOI · Paper page
- 10.1016/j.sab.2009.03.002 · doi:10.1016/j.sab.2009.03.002
- 10.1016/j.talanta.2005.08.027 · DOI
- 10.1016/j.jhazmat.2006.09.075 · DOI
- 10.1039/b204367j · DOI
- 10.1111/ics.12023 · doi:10.1111/ics.12023
- 10.1016/j.jhazmat.2008.03.100 · DOI
- 10.1016/j.sab.2008.09.018 · DOI
- 10.1007/s13738-013-0294-5 · DOI
- 10.1016/j.talanta.2010.02.035 · DOI
- 10.1016/j.talanta.2007.11.009 · DOI
- 10.1016/j.talanta.2012.05.063 · DOI · Paper page
- 10.1016/j.aca.2008.01.020 · DOI
- 10.1016/j.jpba.2012.11.047 · DOI
Cited by
Mansour, F. R., & Danielson, N. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.084 · Cited by 178
Habibollahi, M. H., Karimyan, K., Arfaeinia, H., Mirzaei, N., Safari, Y., Akramipour, R., Sharafi, H., & Fattahi, N. (2019) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.9230 · Cited by 133
Self-citationTen years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Pirsaheb, M., & Fattahi, N. (2018) · RSC Advances · doi:10.1039/c8ra00912k · Cited by 83
Self-citationAhmadi-Jouibari, T., Noori, N., & Fattahi, N. (2021) · Toxin Reviews · doi:10.1080/15569543.2019.1633543 · Cited by 28
Self-citation
Metadata
- Authors
- Sharafi, K., Fattahi, N., Pirsaheb, M., Yarmohamadi, H., & Fazlzadeh Davil, M.
- Venue
- International Journal of Cosmetic Science
- Publisher
- Wiley
- Published
- 2015-05-04
- Volume
- 37
- Issue
- 5
- Pages
- 489-495
- ISSN
- 0142-5463 (ISSN-L)
- 1468-2494
- OpenAlex
- W2066025574
- Cited by
- 61
- References
- 6
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.